MAINTENANCE
Lamp and Filter Replacement
LAMP: Do not operate the Xenon lamp for more than 1000 hours; risk of the lamp shattering increases as a result of changes in the quartz glass. Also, operation beyond 1000 hours signifi- cantly reduces brightness output.
! WARNING !
Never attempt to remove the lamp housing directly after use. The lamp is under great pressure when hot and may explode, causing personal injury and/or property damage.
Allow to cool completely.
The arc lamp operates at a very high temperature and pressure. Failure to allow the lamp to sufficiently cool prior to handling could result in an explosion causing personal injury and/or property damage. After turning the projector off it is important that you wait at least five minutes before unplugging it. This provides enough time for the internal lamp cooling fans to cool the lamp and to automatically shut off. Cool completely before handling.
! WARNING !
Use only lamps supplied by Runco.
FILTER: Replace the side filter every 1000 hours or sooner. If this filter is not replaced, air flow may become restricted and cause the projector to overheat.
See 2.2, Replacing the Lamp and Filter for the complete replacement procedure.
! WARNING !
Use only filters supplied by Runco.
Power Cord and Attachments
Only use attachments or accessories recommended by Runco, such as the 13 amp
! WARNING !
Use only the AC power cord supplied.
Do not attempt operation if the AC supply and
cord are not within the specified voltage and power range.
Do not allow anything to rest on the power cord. Locate the projector where the cord cannot be damaged by persons walking on it or objects rolling over it.
Operate the projector at the specified voltage only. Do not overload power outlets and extension cords as this can result in fire or shock hazards. Runco recommends a dedicated AC circuit for the projector itself.