Omnitron Systems Technology RS-232 user manual Bar Code Message Formatting Selections Group C

Page 16

Bar Code Message Formatting Selections (Group C )

Scanned bar code data can be formatted with the addition of preambles, postambles, and terminator characters. The settings below will augment bar code data scanned by the Omni. A fully-formatted message block reflects the following model:

{Preamble}{Code ID}{Data}{Terminator}{Postamble}

1.Enter BAR CODE MESSAGE FORMATTING SETUP MODE by typing /E/D/FC.

2.Press <ENTER>. The reader should beep twice.

3.Type the two-character selection code for the feature you wish to change.

4.Press <ENTER>. The reader should beep twice.

5.Type the one-character code for the change you wish to make.

6.Press <ENTER>. The reader should beep twice.

7.Save the change and exit the Bar Code Setup Mode by typing CZ.

8.Press <ENTER>. The reader should beep four times.

Note: To review the group’s current setting(s), type CY<ENTER> while in the setup mode. To reset the current setting(s) to its group default, type CX<ENTER> while in

Bar Code Setup Mode.

Bar Code Terminator Character

Enter and Line Feed, Enter, Line Feed, or None: For some applications, it may be convenient to end a string of bar code scan data with a terminator character. For example, with keyboard entry, it is common to have the opera- tor signify the end of the data input with the “Enter” keystroke. The termina- tor character serves this function.

SELECTION CODE: C1

 

 

RETURN and Line Feed

A

 

RETURN

B

 

Line Feed

C

 

None

D

EXAMPLE:

To set the bar code terminator character to Line Feed, enter: /E/D/FC<ENTER>C1<ENTER>C<ENTER>CZ<ENTER>

10

Image 16 Contents
Omnitm Page Limited Warranty Agency ApprovedPage Table of Contents Page Introduction SectionDescription Installation Host ConnectionsConfiguration Configuration Setup ProcedureBar Code Input Magnetic Stripe InputExample Default Settings Serial Interface Parameters Group E Baud Rate ParityGeneral Selections Group B Stop BitCode/Track ID Beep VolumeScan Verification Code ID Definition Group Enter one character for the new IDBar Code Message Formatting Selections Group C Bar Code Terminator CharacterBar Code Preamble Bar Code PostambleMagnetic Stripe Formatting Selections Group D Magnetic Stripe Terminator CharacterMagnetic Stripe Preamble Magnetic Stripe PostambleIndustrial Bar Codes Group F Bar Code SelectionsMinimum and Maximum Length Options Enable/Disable Code Code 39 SettingsFull Ascii Interleaved 2 of 5 Settings Enable/Disable Interleaved 2Check Digit Send Start/Stop CharactersFebraban Conversion Fixed LengthIndustrial 2 of 5 Settings Enable/Disable Industrial 2Code 128 Setting Codabar Settings Enable/Disable CodabarMSI/Plessey Settings Telepen SettingEnable/Disable MSI/Plessey Enable/Disable TelepenEnable/Disable UPC-A UPC SettingsRetail Bar Codes Group G Enable/Disable UPC-E Send Number System DigitSend Check Digit UPC-E ExpansionRead Two-Digit Addendum Read Five-Digit AddendumAddendum Required Add Separator SpaceEAN Settings Enable/Disable EAN-13Enable/Disable EAN-8 Send Induced Country Code CharacterRead Five-Digit Addendum Do Not Read Five-Digit Addendum Track Selection Magnetic Stripe Selections Group HSend Start/Stop Sentinel Reviewing Configuration Settings Track Two Send Accout Number OnlyTrack Separator H4ENTERSELECTED CharacterenterMSI Data Editing Data Fields Data Editing Formulas Formula Sequence Code IdlengthmatchdivideaddsendUsing the Data Editing Functions Track 1 %CABREADOE$JANE$R$310 S Jefferson ST?Data Editing On/Off Data Editing CommandsUnmatched Input Send/Do Not Send Set Length Select Code IDsJDENTER0ENTER6ENTER1ENTER2ENTER Match String Create a Data FieldJEENTER0ENTER8ENTERAENTERBENTER Centerdentereenter JFENTER0ENTER7ENTERAdd a Data Field Search for a Data StringJgenteraenterbentercenter Dentereenter Time Delay Set the Sequence in which Data Fields are SentDelete One Formula JkenteraentercenterbenterReset Data Editing Group Review ConfigurationsExit Data Editing Mode Omni Data FlowSymbology Code ExamplesSend BD DLY 09 AD DLY JDENTER0ENTER7ENTER0Enter 7ENTER JEENTER0ENTER7ENTERMSR Track 1 data Operating Procedure OperationTroubleshooting General ProceduresSerial Interface Problems Scanning Configurations Appendix a Default SettingsCrlf Industrial Bar Codes UPC-A, -E Retail BarcodesUPC-A UPC-E EAN-8 Appendix B Magnetic Stripe FormatAppendix C Magnetic Stripe Standard Data FormatsCalifornia Driver’s License Format Track LRE ID Aamva Driver’s License Format Track Appendix D Full Ascii TableAscii Appendix E Connector PIN-OUTSRS-232 Port, Standard DB-9P Appendix F Installing the DriversUSB/RS-232 Interface Page UE Anyway Telling Whether the Installed Device is Type a or Type B Checking the Installation and Modifying the COM Port NumberTroubleshooting Updating the Driver Date DriverRemoving the Driver Versal Serial BUS ControllersID Tech