Omnitron Systems Technology RS-232 user manual Industrial Bar Codes

Page 55

Industrial Bar Codes

 

Code 39

Enabled

Full ASCII

On

Check Digit

Off

Send Check Digit

No

Send Start/Stop

No

Minimum Length

1

Maximum Length

60

Interleaved 2 of 5

Enabled

Fixed Length

Off

Check Digit

None

Minimum Length

4

Maximum Length

60

Industrial 2 of 5

Enabled

Fixed Length

Off

Check Digit

None

Minimum Length

1

Maximum Length

60

Code 128

Enabled

Minimum Length

1

Maximum Length

60

Codabar

Enabled

Send Start/Stop

No

Check Digit

None

Minimum Length

2

Maximum Length

60

MSI/Plessy

Enabled

Send Check Digit(s)

No

Check Digits

Modulo 10/Modulo 10

Minimum Length

1

Maximum Length

60

49

Image 55
Contents Omnitm Page Agency Approved Limited WarrantyPage Table of Contents Page Introduction SectionDescription Host Connections InstallationMagnetic Stripe Input ConfigurationConfiguration Setup Procedure Bar Code InputExample Serial Interface Parameters Group E Default SettingsParity Baud RateStop Bit General Selections Group BCode/Track ID Beep VolumeScan Verification Enter one character for the new ID Code ID Definition GroupBar Code Terminator Character Bar Code Message Formatting Selections Group CBar Code Postamble Bar Code PreambleMagnetic Stripe Terminator Character Magnetic Stripe Formatting Selections Group DMagnetic Stripe Postamble Magnetic Stripe PreambleIndustrial Bar Codes Group F Bar Code SelectionsMinimum and Maximum Length Options Enable/Disable Code Code 39 SettingsFull Ascii Send Start/Stop Characters Interleaved 2 of 5 SettingsEnable/Disable Interleaved 2 Check DigitFixed Length Febraban ConversionEnable/Disable Industrial 2 Industrial 2 of 5 SettingsCode 128 Setting Enable/Disable Codabar Codabar SettingsEnable/Disable Telepen MSI/Plessey SettingsTelepen Setting Enable/Disable MSI/PlesseyEnable/Disable UPC-A UPC SettingsRetail Bar Codes Group G UPC-E Expansion Enable/Disable UPC-ESend Number System Digit Send Check DigitAdd Separator Space Read Two-Digit AddendumRead Five-Digit Addendum Addendum RequiredSend Induced Country Code Character EAN SettingsEnable/Disable EAN-13 Enable/Disable EAN-8Read Five-Digit Addendum Do Not Read Five-Digit Addendum Track Selection Magnetic Stripe Selections Group HSend Start/Stop Sentinel H4ENTERSELECTED Characterenter Reviewing Configuration SettingsTrack Two Send Accout Number Only Track SeparatorMSI Data Editing Data Fields Data Editing Formulas Code Idlengthmatchdivideaddsend Formula SequenceTrack 1 %CABREADOE$JANE$R$310 S Jefferson ST? Using the Data Editing FunctionsData Editing On/Off Data Editing CommandsUnmatched Input Send/Do Not Send Set Length Select Code IDsJDENTER0ENTER6ENTER1ENTER2ENTER JFENTER0ENTER7ENTER Match StringCreate a Data Field JEENTER0ENTER8ENTERAENTERBENTER CenterdentereenterAdd a Data Field Search for a Data StringJgenteraenterbentercenter Dentereenter Jkenteraentercenterbenter Time DelaySet the Sequence in which Data Fields are Sent Delete One FormulaOmni Data Flow Reset Data Editing GroupReview Configurations Exit Data Editing ModeExamples Symbology CodeJEENTER0ENTER7ENTER Send BD DLY 09 AD DLYJDENTER0ENTER7ENTER0 Enter 7ENTERMSR Track 1 data Operation Operating ProcedureGeneral Procedures TroubleshootingSerial Interface Problems Scanning Configurations Appendix a Default SettingsCrlf Industrial Bar Codes UPC-A, -E Retail BarcodesUPC-A UPC-E EAN-8 Magnetic Stripe Format Appendix BMagnetic Stripe Standard Data Formats Appendix CCalifornia Driver’s License Format Track LRE ID Aamva Driver’s License Format Track Full Ascii Table Appendix DAscii Appendix E Connector PIN-OUTSRS-232 Port, Standard DB-9P Appendix F Installing the DriversUSB/RS-232 Interface Page UE Anyway Telling Whether the Installed Device is Type a or Type B Checking the Installation and Modifying the COM Port NumberTroubleshooting Date Driver Updating the DriverVersal Serial BUS Controllers Removing the DriverID Tech