Omnitron Systems Technology RS-232 user manual Enable/Disable UPC-E, Send Number System Digit

Page 29

Enable/Disable UPC-E

UPC-E is a special version of the UPC-A specification. It is a fixed format symbology and there are no variations allowed. If disabled, the data from the symbology will be disregarded.

SELECTION CODE: G1

UPC-E Enable

C

UPC-E Disable

D

Send Number System Digit

The first encoded digit in the UPC-A symbol is the number system digit. If enabled, the first digit of the transmitted data stream is the number system digit followed by the manufacturer’s number. If disabled, then the first digit transmitted is part of the manufacturer’s number.

SELECTION CODE: G1

Send Number Digit

E

Do Not Send Number Digit

F

Send Check Digit

The check digit is mandatory in the UPC symbology. If enabled, the reader will send the decoded check digit as the last character in the data stream trans- mitted. If not, the check character will be suppressed before transmission.

SELECTION CODE: G1

 

Send Check Digit

G

Do Not Send Check Digit

H

UPC-E Expansion

The UPC-E symbology uses a special algorithm to suppress zeros in the encoded data. The suppressed information can be restored by either the Omni reader or the host system. If enabled, the reader will restore the data to its original format. If the host system is set up to do the expansion, then this op- tion should not be used.

SELECTION CODE: G1

 

Expand UPC-E

I

Do Not Expand UPC-E

J

23

Image 29
Contents Omnitm Page Agency Approved Limited WarrantyPage Table of Contents Page Description SectionIntroduction Host Connections InstallationConfiguration Setup Procedure ConfigurationBar Code Input Magnetic Stripe InputExample Serial Interface Parameters Group E Default SettingsParity Baud RateStop Bit General Selections Group BScan Verification Beep VolumeCode/Track ID Enter one character for the new ID Code ID Definition GroupBar Code Terminator Character Bar Code Message Formatting Selections Group CBar Code Postamble Bar Code PreambleMagnetic Stripe Terminator Character Magnetic Stripe Formatting Selections Group DMagnetic Stripe Postamble Magnetic Stripe PreambleMinimum and Maximum Length Options Bar Code SelectionsIndustrial Bar Codes Group F Full Ascii Code 39 SettingsEnable/Disable Code Enable/Disable Interleaved 2 Interleaved 2 of 5 SettingsCheck Digit Send Start/Stop CharactersFixed Length Febraban ConversionEnable/Disable Industrial 2 Industrial 2 of 5 SettingsCode 128 Setting Enable/Disable Codabar Codabar SettingsTelepen Setting MSI/Plessey SettingsEnable/Disable MSI/Plessey Enable/Disable TelepenRetail Bar Codes Group G UPC SettingsEnable/Disable UPC-A Send Number System Digit Enable/Disable UPC-ESend Check Digit UPC-E ExpansionRead Five-Digit Addendum Read Two-Digit AddendumAddendum Required Add Separator SpaceEnable/Disable EAN-13 EAN SettingsEnable/Disable EAN-8 Send Induced Country Code CharacterRead Five-Digit Addendum Do Not Read Five-Digit Addendum Send Start/Stop Sentinel Magnetic Stripe Selections Group HTrack Selection Track Two Send Accout Number Only Reviewing Configuration SettingsTrack Separator H4ENTERSELECTED CharacterenterMSI Data Editing Data Fields Data Editing Formulas Code Idlengthmatchdivideaddsend Formula SequenceTrack 1 %CABREADOE$JANE$R$310 S Jefferson ST? Using the Data Editing FunctionsUnmatched Input Send/Do Not Send Data Editing CommandsData Editing On/Off JDENTER0ENTER6ENTER1ENTER2ENTER Select Code IDsSet Length Create a Data Field Match StringJEENTER0ENTER8ENTERAENTERBENTER Centerdentereenter JFENTER0ENTER7ENTERJgenteraenterbentercenter Dentereenter Search for a Data StringAdd a Data Field Set the Sequence in which Data Fields are Sent Time DelayDelete One Formula JkenteraentercenterbenterReview Configurations Reset Data Editing GroupExit Data Editing Mode Omni Data FlowExamples Symbology CodeJDENTER0ENTER7ENTER0 Send BD DLY 09 AD DLYEnter 7ENTER JEENTER0ENTER7ENTERMSR Track 1 data Operation Operating ProcedureGeneral Procedures TroubleshootingSerial Interface Problems Scanning Configurations Crlf Default SettingsAppendix a Industrial Bar Codes UPC-A UPC-E EAN-8 Retail BarcodesUPC-A, -E Magnetic Stripe Format Appendix BMagnetic Stripe Standard Data Formats Appendix CCalifornia Driver’s License Format Track LRE ID Aamva Driver’s License Format Track Full Ascii Table Appendix DAscii RS-232 Port, Standard DB-9P Connector PIN-OUTSAppendix E USB/RS-232 Interface Installing the DriversAppendix F Page UE Anyway Troubleshooting Checking the Installation and Modifying the COM Port NumberTelling Whether the Installed Device is Type a or Type B Date Driver Updating the DriverVersal Serial BUS Controllers Removing the DriverID Tech