Omnitron Systems Technology RS-232 user manual Data Editing Commands, Data Editing On/Off

Page 41

Data Editing Commands

1.Enter DATA EDITING mode by typing /E/D/FJ

2.Press <ENTER>. The reader should beep twice.

3.Type the two-character selection code for the function you wish to enable or set.

4.Press <ENTER>. The reader should beep twice.

5.Type the command you wish to enter.

6.Press <ENTER>. The reader should beep twice.

7.Continue to add commands to the data editing formula as desired.

8.Save the formula and exit the data editing mode by typing

JZ <ENTER>. The reader should beep four times.

Note: JZ should only being entered at the end of the entire data editing formula, not after each command. See examples page 41.

Data Editing On/Off

Use this command to turn the Data Editing function on or off.

SELECTION CODE: JA

 

Data Editing Off

0

Data Editing On

1

EXAMPLE:

To turn the Data Editing function on, enter: /E/D/FJ<ENTER>JA<ENTER>1<ENTER>...

Unmatched Input Send/Do Not Send

This command enables or disables the transmission of data that does not meet the restrictions of the data editing formula(s). When SEND ALL DATA is selected, data that does not match any of the formulas will be transmitted anyway, along with any preambles or postambles. When DO NOT SEND is selected, unmatched data will not be sent.

SELECTION CODE: JB

 

If No Formula Matches Data,

0

Do Not Send Data

 

If No Formula Matches Data,

1

Send All Data

 

35

Image 41
Contents Omnitm Page Agency Approved Limited WarrantyPage Table of Contents Page Description SectionIntroduction Host Connections InstallationConfiguration Setup Procedure ConfigurationBar Code Input Magnetic Stripe InputExample Serial Interface Parameters Group E Default SettingsParity Baud RateStop Bit General Selections Group BScan Verification Beep VolumeCode/Track ID Enter one character for the new ID Code ID Definition GroupBar Code Terminator Character Bar Code Message Formatting Selections Group CBar Code Postamble Bar Code PreambleMagnetic Stripe Terminator Character Magnetic Stripe Formatting Selections Group DMagnetic Stripe Postamble Magnetic Stripe PreambleMinimum and Maximum Length Options Bar Code SelectionsIndustrial Bar Codes Group F Full Ascii Code 39 SettingsEnable/Disable Code Enable/Disable Interleaved 2 Interleaved 2 of 5 SettingsCheck Digit Send Start/Stop CharactersFixed Length Febraban ConversionEnable/Disable Industrial 2 Industrial 2 of 5 SettingsCode 128 Setting Enable/Disable Codabar Codabar SettingsTelepen Setting MSI/Plessey SettingsEnable/Disable MSI/Plessey Enable/Disable TelepenRetail Bar Codes Group G UPC SettingsEnable/Disable UPC-A Send Number System Digit Enable/Disable UPC-ESend Check Digit UPC-E ExpansionRead Five-Digit Addendum Read Two-Digit AddendumAddendum Required Add Separator SpaceEnable/Disable EAN-13 EAN SettingsEnable/Disable EAN-8 Send Induced Country Code CharacterRead Five-Digit Addendum Do Not Read Five-Digit Addendum Send Start/Stop Sentinel Magnetic Stripe Selections Group HTrack Selection Track Two Send Accout Number Only Reviewing Configuration SettingsTrack Separator H4ENTERSELECTED CharacterenterMSI Data Editing Data Fields Data Editing Formulas Code Idlengthmatchdivideaddsend Formula SequenceTrack 1 %CABREADOE$JANE$R$310 S Jefferson ST? Using the Data Editing FunctionsUnmatched Input Send/Do Not Send Data Editing CommandsData Editing On/Off JDENTER0ENTER6ENTER1ENTER2ENTER Select Code IDsSet Length Create a Data Field Match StringJEENTER0ENTER8ENTERAENTERBENTER Centerdentereenter JFENTER0ENTER7ENTERJgenteraenterbentercenter Dentereenter Search for a Data StringAdd a Data Field Set the Sequence in which Data Fields are Sent Time DelayDelete One Formula JkenteraentercenterbenterReview Configurations Reset Data Editing GroupExit Data Editing Mode Omni Data FlowExamples Symbology CodeJDENTER0ENTER7ENTER0 Send BD DLY 09 AD DLYEnter 7ENTER JEENTER0ENTER7ENTERMSR Track 1 data Operation Operating ProcedureGeneral Procedures TroubleshootingSerial Interface Problems Scanning Configurations Crlf Default SettingsAppendix a Industrial Bar Codes UPC-A UPC-E EAN-8 Retail BarcodesUPC-A, -E Magnetic Stripe Format Appendix BMagnetic Stripe Standard Data Formats Appendix CCalifornia Driver’s License Format Track LRE ID Aamva Driver’s License Format Track Full Ascii Table Appendix DAscii RS-232 Port, Standard DB-9P Connector PIN-OUTSAppendix E USB/RS-232 Interface Installing the DriversAppendix F Page UE Anyway Troubleshooting Checking the Installation and Modifying the COM Port NumberTelling Whether the Installed Device is Type a or Type B Date Driver Updating the DriverVersal Serial BUS Controllers Removing the DriverID Tech