Omnitron Systems Technology RS-232 user manual Code 128 Setting

Page 25

Check Digit

When Check Digit is selected, the reader takes the last character in the de- coded data stream as a check digit. It then calculates the correct check digit for the remaining data and compares it to the last data character. If it is the same, the data is accepted. If not, the data is rejected. With the Calculate and Send Check Digit option, the reader will send the check digit as part of the data stream. If the Calculate but Do Not Send Check Digit option is selected, the reader will strip it from the data stream before transmission. If the Check Digit is not calculated, the reader will assume the last data character read from the symbol is part of the data stream and will not make a comparison test.

SELECTION CODE: F3

 

Do Not Calculate Check Digit but Send Whole Data Stream

E

Calculate and Send Check Digit

F

Calculate but Do Not Send Check Digit

G

Code 128 Setting:

Enable/Disable Code 128

If enabled, Code 128 symbology will be read, subject to the reading restric- tions specified by this set of options. If disabled, the data from the symbology will be disregarded.

SELECTION CODE: F4

Code 128 Enable

A

Code 128 Disable

B

Note: The Check Digit is manditory for Code 128.

19

Image 25
Contents Omnitm Page Agency Approved Limited WarrantyPage Table of Contents Page Introduction SectionDescription Host Connections InstallationConfiguration Setup Procedure ConfigurationBar Code Input Magnetic Stripe InputExample Serial Interface Parameters Group E Default SettingsParity Baud RateStop Bit General Selections Group BCode/Track ID Beep VolumeScan Verification Enter one character for the new ID Code ID Definition GroupBar Code Terminator Character Bar Code Message Formatting Selections Group CBar Code Postamble Bar Code PreambleMagnetic Stripe Terminator Character Magnetic Stripe Formatting Selections Group DMagnetic Stripe Postamble Magnetic Stripe PreambleIndustrial Bar Codes Group F Bar Code SelectionsMinimum and Maximum Length Options Enable/Disable Code Code 39 SettingsFull Ascii Enable/Disable Interleaved 2 Interleaved 2 of 5 SettingsCheck Digit Send Start/Stop CharactersFixed Length Febraban ConversionEnable/Disable Industrial 2 Industrial 2 of 5 SettingsCode 128 Setting Enable/Disable Codabar Codabar SettingsTelepen Setting MSI/Plessey SettingsEnable/Disable MSI/Plessey Enable/Disable TelepenEnable/Disable UPC-A UPC SettingsRetail Bar Codes Group G Send Number System Digit Enable/Disable UPC-ESend Check Digit UPC-E ExpansionRead Five-Digit Addendum Read Two-Digit AddendumAddendum Required Add Separator SpaceEnable/Disable EAN-13 EAN SettingsEnable/Disable EAN-8 Send Induced Country Code CharacterRead Five-Digit Addendum Do Not Read Five-Digit Addendum Track Selection Magnetic Stripe Selections Group HSend Start/Stop Sentinel Track Two Send Accout Number Only Reviewing Configuration SettingsTrack Separator H4ENTERSELECTED CharacterenterMSI Data Editing Data Fields Data Editing Formulas Code Idlengthmatchdivideaddsend Formula SequenceTrack 1 %CABREADOE$JANE$R$310 S Jefferson ST? Using the Data Editing FunctionsData Editing On/Off Data Editing CommandsUnmatched Input Send/Do Not Send Set Length Select Code IDsJDENTER0ENTER6ENTER1ENTER2ENTER Create a Data Field Match StringJEENTER0ENTER8ENTERAENTERBENTER Centerdentereenter JFENTER0ENTER7ENTERAdd a Data Field Search for a Data StringJgenteraenterbentercenter Dentereenter Set the Sequence in which Data Fields are Sent Time DelayDelete One Formula JkenteraentercenterbenterReview Configurations Reset Data Editing GroupExit Data Editing Mode Omni Data FlowExamples Symbology CodeJDENTER0ENTER7ENTER0 Send BD DLY 09 AD DLYEnter 7ENTER JEENTER0ENTER7ENTERMSR Track 1 data Operation Operating ProcedureGeneral Procedures TroubleshootingSerial Interface Problems Scanning Configurations Appendix a Default SettingsCrlf Industrial Bar Codes UPC-A, -E Retail BarcodesUPC-A UPC-E EAN-8 Magnetic Stripe Format Appendix BMagnetic Stripe Standard Data Formats Appendix CCalifornia Driver’s License Format Track LRE ID Aamva Driver’s License Format Track Full Ascii Table Appendix DAscii Appendix E Connector PIN-OUTSRS-232 Port, Standard DB-9P Appendix F Installing the DriversUSB/RS-232 Interface Page UE Anyway Telling Whether the Installed Device is Type a or Type B Checking the Installation and Modifying the COM Port NumberTroubleshooting Date Driver Updating the DriverVersal Serial BUS Controllers Removing the DriverID Tech