Omnitron Systems Technology RS-232 Read Five-Digit Addendum Do Not Read Five-Digit Addendum

Page 32

Read Two-Digit Addendum

If enabled, the reader will decode the two-digit secondary symbol when it is scanned with the primary symbol, and add the data to the end of the transmis- sion. If not, any two-digit secondary symbol will be ignored.

SELECTION CODE: G2

 

Read Two-Digit Addendum

I

Do Not Read Two-Digit Addendum

J

Read Five-Digit Addendum

This option operates in the same manner as the Read Two Digit Addendum option except it enables the reading of a five digit secondary symbol.

SELECTION CODE: G2

Read Five-Digit Addendum

K

Do Not Read Five-Digit Addendum

L

Addendum Required

If a two or five-digit addendum is enabled, then enabling this option will require an addendum be present before a good read is registered. If not, then symbols with and without the addendum will be accepted.

SELECTION CODE: G2

 

Addendum Required

M

Addendum Not Required

N

Add Separator Space

This option is used with the Two and Five-Digit Addendum options. If en- abled, an ASCII space character is inserted between the data decoded from the primary UPC symbol and the addendum symbol.

SELECTION CODE: G2

 

Add Space Separator

O

Not Add Space Separator

P

26

Image 32
Contents Omnitm Page Limited Warranty Agency ApprovedPage Table of Contents Page Description SectionIntroduction Installation Host ConnectionsConfiguration Configuration Setup ProcedureBar Code Input Magnetic Stripe InputExample Default Settings Serial Interface Parameters Group EBaud Rate ParityGeneral Selections Group B Stop BitScan Verification Beep VolumeCode/Track ID Code ID Definition Group Enter one character for the new IDBar Code Message Formatting Selections Group C Bar Code Terminator CharacterBar Code Preamble Bar Code PostambleMagnetic Stripe Formatting Selections Group D Magnetic Stripe Terminator CharacterMagnetic Stripe Preamble Magnetic Stripe PostambleMinimum and Maximum Length Options Bar Code SelectionsIndustrial Bar Codes Group F Full Ascii Code 39 SettingsEnable/Disable Code Interleaved 2 of 5 Settings Enable/Disable Interleaved 2Check Digit Send Start/Stop CharactersFebraban Conversion Fixed LengthIndustrial 2 of 5 Settings Enable/Disable Industrial 2Code 128 Setting Codabar Settings Enable/Disable CodabarMSI/Plessey Settings Telepen SettingEnable/Disable MSI/Plessey Enable/Disable TelepenRetail Bar Codes Group G UPC SettingsEnable/Disable UPC-A Enable/Disable UPC-E Send Number System DigitSend Check Digit UPC-E ExpansionRead Two-Digit Addendum Read Five-Digit AddendumAddendum Required Add Separator SpaceEAN Settings Enable/Disable EAN-13Enable/Disable EAN-8 Send Induced Country Code CharacterRead Five-Digit Addendum Do Not Read Five-Digit Addendum Send Start/Stop Sentinel Magnetic Stripe Selections Group HTrack Selection Reviewing Configuration Settings Track Two Send Accout Number OnlyTrack Separator H4ENTERSELECTED CharacterenterMSI Data Editing Data Fields Data Editing Formulas Formula Sequence Code IdlengthmatchdivideaddsendUsing the Data Editing Functions Track 1 %CABREADOE$JANE$R$310 S Jefferson ST?Unmatched Input Send/Do Not Send Data Editing CommandsData Editing On/Off JDENTER0ENTER6ENTER1ENTER2ENTER Select Code IDsSet Length Match String Create a Data FieldJEENTER0ENTER8ENTERAENTERBENTER Centerdentereenter JFENTER0ENTER7ENTERJgenteraenterbentercenter Dentereenter Search for a Data StringAdd a Data Field Time Delay Set the Sequence in which Data Fields are SentDelete One Formula JkenteraentercenterbenterReset Data Editing Group Review ConfigurationsExit Data Editing Mode Omni Data FlowSymbology Code ExamplesSend BD DLY 09 AD DLY JDENTER0ENTER7ENTER0Enter 7ENTER JEENTER0ENTER7ENTERMSR Track 1 data Operating Procedure OperationTroubleshooting General ProceduresSerial Interface Problems Scanning Configurations Crlf Default SettingsAppendix a Industrial Bar Codes UPC-A UPC-E EAN-8 Retail BarcodesUPC-A, -E Appendix B Magnetic Stripe FormatAppendix C Magnetic Stripe Standard Data FormatsCalifornia Driver’s License Format Track LRE ID Aamva Driver’s License Format Track Appendix D Full Ascii TableAscii RS-232 Port, Standard DB-9P Connector PIN-OUTSAppendix E USB/RS-232 Interface Installing the DriversAppendix F Page UE Anyway Troubleshooting Checking the Installation and Modifying the COM Port NumberTelling Whether the Installed Device is Type a or Type B Updating the Driver Date DriverRemoving the Driver Versal Serial BUS ControllersID Tech