Industrial 2 of 5 Settings:
Enable/Disable Industrial 2 of 5
If enabled, Industrial 2 of 5 symbology will be read, subject to the reading restrictions specified by this set of options. If disabled, the data from the sym- bology will be disregarded.
SELECTION CODE: F3 |
|
Industrial 2 of 5 Enable | A |
Industrial 2 of 5 Disable | B |
Fixed Length
Industrial 2 of 5 symbols are commonly printed in a fixed format contain- ing a fixed number of characters. If this option is ON, the first Interleaved 2 of 5 symbol scanned after power up will set the length of any other symbols scanned afterwards. If the succeeding scans do not match the length of the first scan, the scan is rejected by the reader. Power must be reset before an Interleaved 2 of 5 symbol of a different length will be accepted.
SELECTION CODE: F3 |
|
Turn On Fixed Length | C |
Turn Off Fixed Length | D |
18