M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l
Table 6: DIP Switch Setting for TereScope
Function | TS700/155 | TS800/155 | |||
| OFF |
| ON | OFF | ON |
Fast Ethernet | 4,5 |
| – | 1,2,3,4 | – |
ATM/OC3/STM1: 155 Mbps | – |
| 4,5 | 2,3,4 | 1 |
SMPTE 143 Mbps |
| – | 3,4 | 1,2 | |
E3:34.368 Mbps | 5 |
| 4 | 1,2,4 | 3 |
T3:44.736 | 4 |
| 5 | 2,4 | 1,3 |
OC1/STMO:51.840 Mbps |
| – | 1,4 | 2,3 | |
Customized 1 |
| – | 4 | 1,2,3 | |
Customized 2 |
| – | 1,3,4 | 2 | |
Open Protocol |
| – | 1,2,3 | 4 |
Mode Select DIP switch toggle
Set DIP switch toggles 1 and 2 to the OFF position for normal operation. (In TS800/155 and
2–TS700/100(Fastethernet)
Compatibility
Peripheral equipment
Check the operation of the peripheral equipment connected with cables (see Configuration 1 below).
Interfaces
Check the specifications compatibility (type, data rate) between the TereScope and the peripheral equipment interfaces.
Test equipment
Chose an appropriate Bit Error Rate (BER) tester for checking the physical link quality. A portable one is preferable since it is more convenient for use in the field.
A ping test or a file transfer between two workstations - connected to the networking equipment - is useful and easy to implement for testing the performance of the whole configuration.
Setup
DIP Switch
Set DIP switch toggles 1 and 2 to the OFF position for normal operation.
Set DIP switch toggle 4 for the speed. Usually with Cisco Switches set the TS to
27