MRV Communications TS700/G, TS700/155, TS800/155 Mounting on a fragile/crumbly wall, Jmp-L

Page 47

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

To use the floor, a very stable tower standing on the floor is required. The transceiver will be fixed on the top of the tower.

Two techniques using a small concrete block are suggested for stabilizing the tower on the floor.

The concrete slab material is poured directly on the base of the tower

Four bolts are inserted in the concrete slab placed on the floor. The tower mount is fixed on the slab with the inserted bolts using nuts.

Transceiver

JAH

JMP-L

Tower Mount

Concrete Slab

Floor

Figure 5.15: Mounting on a concrete slab

!THE SLAB/TOWER BASE AND THE FLOOR. ONCE THE INSTALLATION IS COMPLETED, RESTORE THE ROOF WATER-TIGHTNESS WITH SEALING MATERIAL AROUND THE SLAB.TAKE CARE TO REMOVE ANY INTERVENING SOFT MATERIAL, SUCH AS ASPHALT, BETWEEN

2- Mounting on a fragile/crumbly wall

On sites on which the installation on fragile (pre-fab) or crumbly (old building) walls is unavoidable, the best way to strongly fix the JMB is to use a metallic clamping plate on the other side of the wall as sketched below. In this technique a large section of the wall is clasped providing higher rigidity and stability.

Fragile Wall

Clamping Plate

Figure 5.16: Mounting on a Fragile wall

37

Image 47
Contents UserManual UserManual TableofContents P E N D I CE Mark StandardsStandards Compliance FCC NoticeTrademarks MRV  Laser Safety CertificationOther Standards DisclaimerAboutthisUserManual Before Installing SafetyRequirementsServicing Introduction Carefully Read the Entire Manual Before InstallingModels Part Number Description Using the Part Number for OrderingTheProduct Front MRV Back Panel Description TS800/155 Standard Model DS1 Toggles Data Rate DIP switch TS800/155-F Standard Model including Fusion option RF Transceiver Fusion Operation Mode5b TS & Fusion FusionTS700/100 Fast-Ethernet System OFF Auto-negotiation, on Forced MRV Display LEDs,Dry Dry contact Only TS800 Monitoring and Management optionsManagement Copper Connection Typical ConnectionFiber Connection Location & Range SiteSurveyLine of Sight OrientationConsult Factory in Case of Doubt Optimal Mounting Unacceptable Mounting Mounting Environment & StabilityPage Transmitting through a Window Wall Mounting using JMP and JMB12 shows the arrangement for transmitting through a window Infrastructure PowerData/Signal Cabling Handle the Fibers Very Carefully Test equipment SetupBenchTest CompatibilityTS700/100Fastethernet IR link Bench testDisplay and Results IndicatorsExpected Results Received powerDescription InstallationAccessories TereScope Parts External view Part DescriptionAiming Head Adjustment and Locks Detachment of the TS from the JMP-L Installer Tool Kit JITK-LMounting Standard position a Mounting the accessoriesMounting on the floor Special MountingJMP-L Mounting on a fragile/crumbly wall17 Alignment kit mountedon JMP-L Back view Attachment of the Transceiver TereScope HeadPowering on the TereScope AimingProcedureTools and Equipment ProcedureTransceiver Alignment GeneralFine Alignment 13 Position after the horizontal aiming 15a and 6.15b Alignment screws Visual Inspection InstallationCompletionLink Operating Test Before Closing the Rear Door17 Mounted TereScope Left View Periodic Visits MaintenanceAccuracy should be examined and restored if necessary Appendix a TS700/100 Fast-Ethernet Light TS800/155 high speed Light TS700/G Giga-Light Appendixb Packing box contains AppendixcAppendixd List of the Tools Supplied by MRV Communications Where to usePoints to Remember IntroductionInterference Figure E.3 Active Transmitters Shown Darkened Page Appendixf Effect of Wind on Terescopes FSO Chaining AppendixGIndirect Chaining Use the indoor switch in building C for the chainingFSO products & Chaining Product series No of chained links Appendixh Site survey Installation System failure Appendixi