MRV Communications TS700/155, TS800/155, TS700/100, TS700/G Position after the horizontal aiming

Page 52

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

Fine Alignment Vertical Motion Screws – Two screws (‘C’). Used for fine rotation of the TereScope in the vertical plane.

Fine Alignment Horizontal Motion Screws – Two screws (‘B’). Used for fine rotation of the TereScope in the horizontal plane..

Note

#Two installers are required for fine alignment, one at each TereScope site.

#The installers should each have a walkie-talkie, a mobile phone or any other equipment to enable each to talk to the other working at the opposite site.

The fine alignment procedure is as follows:

1.Find the horizontal and vertical Beam edges (H1, H2, V1, V2) by obtaining a reading between 50 and 80 on the 7-segment display. (between 250 and 300 for the TS700/G)

2.Set successively the remote transceiver in the middle of the two segments [H1,H2] and [V1,V2].

V1

H1

H2

V2 Figure 6.12: Position at the beginning (after the coarse alignment)

Important: Do not in any case select the head position for which the DVM reading is maximum! The best position of alignment is the beam center.

To determine the horizontal beam edges H1 and H2, move the local transceiver slowly left and right until the digital readout on the remote transceiver becomes 50. (250 for the TS700/G) Identify these two points relative to reference points on the opposite site by looking through the telescope. By moving the local transceiver, set the remote transceiver at the middle of these two reference points.

V1

H1

H2

V2

Figure 6.13: Position after the horizontal aiming

42

Image 52
Contents UserManual UserManual TableofContents P E N D I Standards Standards ComplianceFCC Notice CE MarkMRV  Laser Safety Certification Other StandardsDisclaimer TrademarksAboutthisUserManual SafetyRequirements Before InstallingServicing Carefully Read the Entire Manual Before Installing IntroductionTheProduct Using the Part Number for OrderingModels Part Number Description Front MRV Back Panel Description TS800/155 Standard Model DS1 Toggles Data Rate DIP switch TS800/155-F Standard Model including Fusion option Fusion Operation Mode RF TransceiverFusion 5b TS & FusionTS700/100 Fast-Ethernet System OFF Auto-negotiation, on Forced MRV Display LEDs,Dry Management Monitoring and Management optionsDry contact Only TS800 Fiber Connection Typical ConnectionCopper Connection SiteSurvey Line of SightOrientation Location & RangeConsult Factory in Case of Doubt Optimal Mounting Mounting Environment & Stability Unacceptable MountingPage Wall Mounting using JMP and JMB Transmitting through a Window12 shows the arrangement for transmitting through a window Data/Signal Cabling PowerInfrastructure Handle the Fibers Very Carefully Setup BenchTestCompatibility Test equipmentTS700/100Fastethernet Bench test IR linkIndicators Display and ResultsReceived power Expected ResultsAccessories InstallationDescription Part Description TereScope Parts External viewAiming Head Adjustment and Locks Mounting Installer Tool Kit JITK-LDetachment of the TS from the JMP-L Mounting the accessories Standard position aSpecial Mounting Mounting on the floorMounting on a fragile/crumbly wall JMP-LAttachment of the Transceiver TereScope Head 17 Alignment kit mountedon JMP-L Back viewAimingProcedure Powering on the TereScopeProcedure Transceiver AlignmentGeneral Tools and EquipmentFine Alignment 13 Position after the horizontal aiming 15a and 6.15b Alignment screws InstallationCompletion Link Operating TestBefore Closing the Rear Door Visual Inspection17 Mounted TereScope Left View Accuracy should be examined and restored if necessary MaintenancePeriodic Visits Appendix a TS700/100 Fast-Ethernet Light TS800/155 high speed Light TS700/G Giga-Light Appendixb Appendixc Packing box containsAppendixd Where to use List of the Tools Supplied by MRV CommunicationsIntroduction Points to RememberInterference Figure E.3 Active Transmitters Shown Darkened Page Appendixf Effect of Wind on Terescopes AppendixG FSO ChainingUse the indoor switch in building C for the chaining Indirect ChainingFSO products & Chaining Product series No of chained links Appendixh Site survey Installation System failure Appendixi