Multi-Tech Systems MT5634MSV manual Independent Mode Operation in PhoneTools

Page 30

MessageSaver User Guide

Independent Mode Operation in PhoneTools

In PhoneTools, Independent mode control is provided in two dialog boxes: the Inde- pendent Mode Configuration dialog box, and the Independent Mode Control dia- log box. When PhoneTools is running, you can open either dialog box to change settings, download files, or do any work related to Independent mode.

Independent Mode Configuration Dialog Box

The Independent Mode Configuration dialog box (Figure 3-1) enables you to:

Turn Independent mode on or off while the PhoneTools is running.

Specify whether Independent mode should be activated when PhoneTools closes.

Turn on call screening.

Specify an access code for remote message retrieval.

Select and download an Independent mode greeting message to the modem.

Display which Independent mode greeting message is stored in the modem.

If automatic activation of Independent mode is selected, the settings are uploaded to the modem when you exit the application. If automatic activation cannot be com- pleted for any reason (e.g., modem not responding, no greeting message specified, etc.), you are notified so you can return to PhoneTools to fix the problem.

Figure 3-1.Independent Mode Configuration dialog box

22

Image 30
Contents User Guide FCC Part User Guide Record of Revisions Introduction Quick StartMessageSaver Operation Solving Problems AT Commands, S-Registers & Result CodesRemote Configuration PhoneToolsAppendix a Regulatory Compliance Appendix C Loopback TestsAppendix D Warranty, Service, and Technical Support Appendix E Upgrade ProceduresIntroduction Introduction Product Description What Is in Your Modem Package? How to Get a Copy of Your User Guide Related ManualsMessageSaver User Guide Quick Start What You Will Need Safety WarningsIntroduction We supplyMount the Feet Select Stereo or Mono SpeakerOpening the Modem Changing the Speaker Jumper Location of speaker jumperConnect the Modem to Your System RS232 ConnectionLine Connection Phone Connection Power ConnectionPower-On Test Microphone ConnectionInstall the Modem in Windows Adding the Modem to WindowsRemoving Your Old Modem from Windows Install and Configure Your Software Call the Multi-Tech BBS Windows HyperTerminal Windows Terminal Send a Fax Microsoft FaxSelect Start Programs Accessories Fax Compose new fax ReferencesMessageSaver User Guide MessageSaver Operation PhoneTools Features Independent Mode FunctionsRecording and Downloading an Announcement MessageSaver OperationIndependent Mode Operation in PhoneTools Independent Mode Configuration Dialog BoxIndependent Mode Control Dialog Box Independent Mode Control dialog boxIndependent Mode Operation Using the Front Panel Control ButtonsIndicator Lights Playing Voice Messages Adjusting Speaker VolumeAnswering a Call with the Speakerphone Stopping the Play of Voice MessagesRemote Control Using the MessageSaver in Speakerphone ModeControlling the MessageSaver Remotely Activating Independent Mode Remotely Remote Control KeysAT Commands Registers Result Codes AT Commands AT Command Summary Echo Online Data Characters Echo Command Mode CharactersDS=y Dial Stored Telephone Number Hook ControlReturn Online to Data Mode Monitor Speaker VolumeMonitor Speaker Mode Modulation HandshakeSr? Read Register Value Result Codes Enable/DisableSet Register Value Tone DialingAuto Retrain Modem ResetLong Space Disconnect Data Carrier Detect DCD ControlAsynchronous Communications Mode Load Factory SettingsCommunications Mode 22bis Guard Tone ControlStore Current Configuration Test CommandsDisplay Current Settings Select Stored Configuration for Hard Reset\Gn Modem Port Flow Control \An\Bn Transmit Break \Jn Data Buffer Control\Nn Error Correction Mode Selection \Tn Inactivity Timer\Qn Flow Control Selection \Xn XON/XOFF Pass-Through DCn AT Command Control\Vn Protocol Result Code Data Calling Tone#S=x Store Setup Password Command +ES=n Enable Synchronous Buffered Mode#Sx Enter Setup Password Command +++ATCR Escape SequenceRegister Unit Range Default Description RegistersRegister Unit Range Default Description S37 Register Unit Range Default Description S42 Result Codes Terse Verbose DescriptionBlacklist Full Remote Configuration Basic Procedure SetupChanging the Setup Password Changing the Remote Escape Character MessageSaver User Guide Solving Problems None of the Indicators Light Modem Does Not Respond to Commands Modem Dials But Cannot Connect Modem4Disconnects While Online Modem4Cannot Connect When Answering File Transfer4Is Slower Than It Should BeData Is Being Lost There Are Garbage4 Characters on the Monitor Modem4Doesn’t Work with Caller IDFax and Data4Software Can’t Run at the Same Time MessageSaver User Guide PhoneTools Installing PhoneTools Using PhoneTools’ Status Bar Phone ModuleMaking a Phone Call Using the Speakerphone Making Quick Dial EntriesSetting up Answerphone Voice ModuleActivating and Deactivating Answerphone Setting Up the Answer Only Mode Setting Up the Answer/Record ModeListening to Received Messages from a Remote Phone Listening to Received Messages in PhoneToolsRecording an Announcement Changing Recording ParametersIndependent Mode Configuring and Controlling Independent Mode OperationHow Does It Work? Activating and Configuring Independent Mode Selecting an AnnouncementIndependent Mode Managing Stored Documents InboxFax Module Faxing a Document from a Windows ApplicationFaxing a File Directly from PhoneTools Sending a CoverAdding a Logo to the Cover Viewing and Printing FaxesInbox and Outbox Management Inbox ManagementOutbox Management Importing Existing Records Phone BookCreating New Records Selecting RecordsUsing the Phone Book for Dialing Terminal Emulation Module Starting a Modem ConnectionUploading Files to a Remote System Capturing Information to DiskData File Transfer Sending a Data File AutomaticallyReceiving a Data File Automatically Appendixes Appendix a Regulatory Compliance FCC Part 68 TelecomFax Branding Statement Regulatory ComplianceCanadian Limitations Notice International Modem RestrictionsCommission Decision CTR21 EMC and Safety Compliance New Zealand Telecom Warning NoticeMessageSaver User Guide Appendix B Technical Specifications Carrier Frequencies Frequency Stability MessageSaver User Guide Test procedure Local Analog Loopback Test V.54 LoopRemote Digital Loopback Test V.54 Loop Figure C-2. Remote digital loopback testLocal Digital Loopback Test V.54 Loop Figure C-3. Local digital loopback testMessageSaver User Guide Limited Warranty ServiceOnline Warranty Registration Technical SupportMulti-Tech BBS About the Internet Modem Accessories About the Multi-Tech Fax-Back ServiceSupplyNet Online Ordering Instructions Upgrade Overview Identify the Modem FirmwareIdentify the Current Firmware Version Multi-Tech Web SiteMulti-Tech BBS Download the Upgrade File Extract the Upgrade FilesClear Your Stored Paramenters Upgrade the Modem’s Firmware Restore Your ParametersIndex Symbols Index 106