Multi-Tech Systems MT5634MSV manual Register Unit Range Default Description S37

Page 51

4 AT Commands, S-Registers, and Result Codes

Register

Unit

Range

Default

Description

S37

decimal

0–19

0

Sets the maximum V.34 “upstream” speed at

 

 

 

 

which the modem attempts to connect.

0 = maximum modem speed

1 = reserved

2 = 1200/75 bps

3 = 300 bps

4 = reserved

5 = 1200 bps

6 = 2400 bps

7 = 4800 bps

8 = 7200 bps

9 = 9600 bps

10 = 12000 bps

11 = 14400 bps

12 = 16800 bps

13 = 19200 bps

14 = 21600 bps

15 = 24000 bps

16 = 26400 bps

17 = 28800 bps

18 = 31200 bps

19 = 33600 bps

S38

decimal 0–23

1

Sets the maximum 56K “downstream” speed

 

 

 

at which the modem attempts to connect.

 

 

 

The default maximum speed is 56K bps.

 

 

 

Value

V.90 mode

K56flex mode

 

 

 

 

0

56K disabled

56K disabled

 

 

 

1

56K autorate

56K autorate

 

 

 

2

28000 bps

32000 bps

 

 

 

3

29333 bps

34000 bps

 

 

 

4

30666 bps

36000 bps

 

 

 

5

32000 bps

38000 bps

 

 

 

6

33333 bps

40000 bps

 

 

 

7

34666 bps

42000 bps

 

 

 

8

36000 bps

44000 bps

 

 

 

9

37333 bps

46000 bps

 

 

 

10

38666 bps

48000 bps

 

 

 

11

40000 bps

50000 bps

 

 

 

12

41333 bps

52000 bps

 

 

 

13

42666 bps

54000 bps

 

 

 

14

44000 bps

56000 bps

 

 

 

15

45333 bps

 

 

 

 

 

16

46666 bps

 

 

 

 

 

17

48000 bps

 

 

 

 

 

18

49333 bps

 

 

 

 

 

19

50666 bps

 

 

 

 

 

20

52000 bps

 

 

 

 

 

21

53333 bps

 

 

 

 

 

22

54666 bps

 

 

 

 

 

23

56000 bps

 

 

43

Image 51
Contents User Guide FCC Part User Guide Record of Revisions Introduction Quick StartMessageSaver Operation PhoneTools AT Commands, S-Registers & Result CodesRemote Configuration Solving ProblemsAppendix C Loopback Tests Appendix a Regulatory ComplianceAppendix E Upgrade Procedures Appendix D Warranty, Service, and Technical SupportIntroduction Introduction Product Description How to Get a Copy of Your User Guide Related Manuals What Is in Your Modem Package?MessageSaver User Guide Quick Start We supply Safety WarningsIntroduction What You Will NeedMount the Feet Select Stereo or Mono SpeakerOpening the Modem Location of speaker jumper Changing the Speaker JumperConnect the Modem to Your System RS232 ConnectionLine Connection Microphone Connection Power ConnectionPower-On Test Phone ConnectionInstall the Modem in Windows Adding the Modem to WindowsRemoving Your Old Modem from Windows Install and Configure Your Software Call the Multi-Tech BBS Windows HyperTerminal Windows Terminal Microsoft Fax Send a FaxReferences Select Start Programs Accessories Fax Compose new faxMessageSaver User Guide MessageSaver Operation Independent Mode Functions PhoneTools FeaturesMessageSaver Operation Recording and Downloading an AnnouncementIndependent Mode Configuration Dialog Box Independent Mode Operation in PhoneToolsIndependent Mode Control dialog box Independent Mode Control Dialog BoxControl Buttons Independent Mode Operation Using the Front PanelIndicator Lights Stopping the Play of Voice Messages Adjusting Speaker VolumeAnswering a Call with the Speakerphone Playing Voice MessagesRemote Control Using the MessageSaver in Speakerphone ModeControlling the MessageSaver Remotely Remote Control Keys Activating Independent Mode RemotelyAT Commands Registers Result Codes AT Commands AT Command Summary Hook Control Echo Command Mode CharactersDS=y Dial Stored Telephone Number Echo Online Data CharactersModulation Handshake Monitor Speaker VolumeMonitor Speaker Mode Return Online to Data ModeTone Dialing Result Codes Enable/DisableSet Register Value Sr? Read Register ValueData Carrier Detect DCD Control Modem ResetLong Space Disconnect Auto Retrain22bis Guard Tone Control Load Factory SettingsCommunications Mode Asynchronous Communications ModeSelect Stored Configuration for Hard Reset Test CommandsDisplay Current Settings Store Current Configuration\Jn Data Buffer Control \An\Bn Transmit Break \Gn Modem Port Flow Control\Nn Error Correction Mode Selection \Tn Inactivity Timer\Qn Flow Control Selection Data Calling Tone DCn AT Command Control\Vn Protocol Result Code \Xn XON/XOFF Pass-ThroughCommand +++ATCR Escape Sequence Command +ES=n Enable Synchronous Buffered Mode#Sx Enter Setup Password #S=x Store Setup PasswordRegisters Register Unit Range Default DescriptionRegister Unit Range Default Description S37 Register Unit Range Default Description S42 Terse Verbose Description Result CodesBlacklist Full Remote Configuration Basic Procedure SetupChanging the Setup Password Changing the Remote Escape Character MessageSaver User Guide Solving Problems None of the Indicators Light Modem Does Not Respond to Commands Modem Dials But Cannot Connect Modem4Disconnects While Online Modem4Cannot Connect When Answering File Transfer4Is Slower Than It Should BeData Is Being Lost There Are Garbage4 Characters on the Monitor Modem4Doesn’t Work with Caller IDFax and Data4Software Can’t Run at the Same Time MessageSaver User Guide PhoneTools Installing PhoneTools Using PhoneTools’ Status Bar Phone ModuleMaking a Phone Call Making Quick Dial Entries Using the SpeakerphoneSetting up Answerphone Voice ModuleActivating and Deactivating Answerphone Setting Up the Answer/Record Mode Setting Up the Answer Only ModeListening to Received Messages in PhoneTools Listening to Received Messages from a Remote PhoneChanging Recording Parameters Recording an AnnouncementIndependent Mode Configuring and Controlling Independent Mode OperationHow Does It Work? Selecting an Announcement Activating and Configuring Independent ModeManaging Stored Documents Inbox Independent ModeFaxing a Document from a Windows Application Fax ModuleSending a Cover Faxing a File Directly from PhoneToolsViewing and Printing Faxes Adding a Logo to the CoverInbox Management Inbox and Outbox ManagementOutbox Management Selecting Records Phone BookCreating New Records Importing Existing RecordsUsing the Phone Book for Dialing Starting a Modem Connection Terminal Emulation ModuleCapturing Information to Disk Uploading Files to a Remote SystemSending a Data File Automatically Data File TransferReceiving a Data File Automatically Appendixes FCC Part 68 Telecom Appendix a Regulatory ComplianceRegulatory Compliance Fax Branding StatementCanadian Limitations Notice International Modem RestrictionsCommission Decision CTR21 New Zealand Telecom Warning Notice EMC and Safety ComplianceMessageSaver User Guide Appendix B Technical Specifications Carrier Frequencies Frequency Stability MessageSaver User Guide Local Analog Loopback Test V.54 Loop Test procedureFigure C-2. Remote digital loopback test Remote Digital Loopback Test V.54 LoopFigure C-3. Local digital loopback test Local Digital Loopback Test V.54 LoopMessageSaver User Guide Service Limited WarrantyOnline Warranty Registration Technical SupportMulti-Tech BBS About the Internet Modem Accessories About the Multi-Tech Fax-Back ServiceSupplyNet Online Ordering Instructions Identify the Modem Firmware Upgrade OverviewIdentify the Current Firmware Version Multi-Tech Web SiteMulti-Tech BBS Download the Upgrade File Extract the Upgrade FilesClear Your Stored Paramenters Restore Your Parameters Upgrade the Modem’s FirmwareIndex Symbols Index 106