Datacom Systems VS-1200 manual # SET IP Subnet Gateway, SET Date Mmddyy

Page 23

Initial Configuration

23

4.1.4.5SET IP (SE IP), SUBNET (SU), GATEWAY (GA)

This command configures the IP address (default 192.168.1.1), Subnet Mask (default 255.255.255.0) and Default Gateway (default 0.0.0.0) parameters. Initially, it is highly recommended that this be done through the direct serial connection using the HyperTerminal or equivalent terminal emulation application. Only those variables that require configuration need to be entered.

The parameters may be entered separately as shown:

#SET IP (SE IP) [IP Address nnn.nnn.nnn.nnn] [SUBNET] [GATEWAY]

#SET SUBNET (SE SU) [Subnet Mask nnn.nnn.nnn.nnn]

#SET GATEWAY (SE GA) [Default Gateway nnn.nnn.nnn.nn*n]

Example: # SE IP 172.169.50.134

IP will be updated at end of session

# SE SU 255.255.0.0

Subnet Mask will be updated at end of session

# SE GA 172.169.50.1

Default Gateway will be updated at end of session

#

Or, the parameters can also be entered jointly, (i.e., IP Address, Subnet Mask, Default Gateway) but entry must be in the proper sequence order and separated by a space delimiter, as shown:

# SET IP [SUBNET] [GATEWAY]

Example: # SE IP 172.169.50.134 255.255.0.0 172.169.50.1

IP will be updated at end of session

Subnet Mask will be updated at end of session

Default Gateway will be updated at end of session

#

4.1.4.6SET DATE (SE DA)

This command, followed by the date (MMDDYY), sets the real time clock date as shown:

SET DATE (MMDDYY)

Example: # SE DA 123107

#

© 2009 Datacom Systems Inc

Image 23
Contents USERguide Page Product Description Datacom Systems Inc VS-1200 Data Acccess SwitchTable of Contents VS-1200 Series Functional Drawing Application Hardware InstallationCustomer Service Certifications and Marks Terms of UseCopyright License Agreement Trademark Attribution Proprietary NoticeSafety Notices and Warnings VS-1200 Series Summary OverviewWhat Shipped? VS-1200 Series Features and BenefitsOperating Range Relative Humidity 5 to 90% non-condensing VS-1200 Series Common SpecificationsVS-1200 Series Model Specific Specifications Power Consumption 12W BTU/hPage VS-1210BT/SFP HardwareVS-1200 Series Front Panels Any-to-Any Ports PowerFront Panel Description Management Port Rear Panel DescriptionRear Label BT series Power Switch SFP seriesInput Power Serial DB9Basic Functionality Initial ConfigurationCommand Line Interface CLI Basic Commands Read Only Access Password RecoverySET Port Monitor SE PO MO TAP Show Groups SH GR Group NameShow Port Routing SH PO RO Show Users SH US Superuser Commands Configuration AccessSU SET Password SU SE PA SET Date Mmddyy # SET IP Subnet Gateway# SE PO MO 3 OFF SET Time HhmmssADD User AD US HyperTerminal Serial Port Configuration DB9Delete User Username Port Number Management Port Configuration RJ45TCP/IP Winsock Telnet IP Address ConfigurationIP Address Configuration with HyperTerminal Accessories Communications HyperTerminal VS-1200 Data Acccess Switch Initial Configuration IP Address Configuration with Telnet Network Connections Accessories Command Prompt Initial Configuration Exercise CLI Setting Ports Initial Configuration # SET Port Monitor 2 from 8,9 # SET Port Monitor 1 from 7,9# SET Port Monitor 8 from # SET Port Monitor 5 from# SET Port Monitor 6 from 3,4 # SET Port Monitor 7 fromIntallation Prerequisites Safety GuidelinesSmall Form-Factor Plug Module Removing the SFP Module Installing the SFP ModulePage Any-to-Any Connection Hardware InstallationPower Management Connection VS-1210BT-BT/SFP VS-1200 Series Functional DrawingVS-1204BT VS-1204SFP Application Gathering the Data HyperTerminal configuration exampleVS-1200 Data Acccess Switch # SET Port Monitor 9 from # SET Port Monitor 4 from# SET Port Monitor 6 from VS-1200 Data Acccess Switch Application # SET Port Monitor 8 from 2,4 # SET Port Monitor 5 from 1,3# SET Port Monitor 6 from 1,3 # SET Port Monitor 7 from 2,4Limits of Liability Customer ServiceInternet Warranty Datacom Systems Inc