Datacom Systems VS-1200 manual Application, Gathering the Data HyperTerminal configuration example

Page 47

Application

47

7 Application

This section will present techniques and applications describing the practical use and new remedies

for performing network analysis requirements using VS-1200 series solutions.

7.1Gathering the Data (HyperTerminal configuration example)

PREMISE: This application consists of workgroup switches that allow end users to access a group of servers. The servers are connected to a single server switch and the users are distributed across several workgroup switches. The security department wants to see all server bound access from the users and server to server traffic.

GOAL: This application will use a VS-1210BT/SFP as follows:

1.TAP access to critical server

2.Aggregate SPAN.

3.Provide access for analysis, security and recording devices.

The first goal requires an external tap between the server switch and the critical financial server. The tap copies all the data going to the financial server, and can't be shutdown like a SPAN port. The tap allows enhanced visibility for security purposes.

The second goal requires that a SPAN port is configured on the workgoup switches. This will only allow workgroup traffic to be replicated out the SPAN port.

The third goal involves aggregating and replicating traffic from the two previous goals for specific security and network analysis to be done.

© 2009 Datacom Systems Inc

Image 47
Contents USERguide Page Product Description Datacom Systems Inc VS-1200 Data Acccess SwitchTable of Contents VS-1200 Series Functional Drawing Application Hardware InstallationCustomer Service Certifications and Marks Terms of UseCopyright License Agreement Trademark Attribution Proprietary NoticeSafety Notices and Warnings VS-1200 Series Summary OverviewWhat Shipped? VS-1200 Series Features and BenefitsOperating Range Relative Humidity 5 to 90% non-condensing VS-1200 Series Common SpecificationsVS-1200 Series Model Specific Specifications Power Consumption 12W BTU/hPage VS-1210BT/SFP HardwareVS-1200 Series Front Panels Any-to-Any Ports PowerFront Panel Description Management Port Rear Panel DescriptionRear Label BT series Power Switch SFP seriesInput Power Serial DB9Basic Functionality Initial ConfigurationCommand Line Interface CLI Basic Commands Read Only Access Password RecoverySET Port Monitor SE PO MO TAP Show Groups SH GR Group NameShow Port Routing SH PO RO Show Users SH US Superuser Commands Configuration AccessSU SET Password SU SE PA SET Date Mmddyy # SET IP Subnet Gateway# SE PO MO 3 OFF SET Time HhmmssADD User AD US HyperTerminal Serial Port Configuration DB9Delete User Username Port Number Management Port Configuration RJ45TCP/IP Winsock Telnet IP Address ConfigurationIP Address Configuration with HyperTerminal Accessories Communications HyperTerminal VS-1200 Data Acccess Switch Initial Configuration IP Address Configuration with Telnet Network Connections Accessories Command Prompt Initial Configuration Exercise CLI Setting Ports Initial Configuration # SET Port Monitor 2 from 8,9 # SET Port Monitor 1 from 7,9# SET Port Monitor 8 from # SET Port Monitor 5 from# SET Port Monitor 6 from 3,4 # SET Port Monitor 7 fromIntallation Prerequisites Safety GuidelinesSmall Form-Factor Plug Module Removing the SFP Module Installing the SFP ModulePage Any-to-Any Connection Hardware InstallationPower Management Connection VS-1210BT-BT/SFP VS-1200 Series Functional DrawingVS-1204BT VS-1204SFP Application Gathering the Data HyperTerminal configuration exampleVS-1200 Data Acccess Switch # SET Port Monitor 9 from # SET Port Monitor 4 from# SET Port Monitor 6 from VS-1200 Data Acccess Switch Application # SET Port Monitor 8 from 2,4 # SET Port Monitor 5 from 1,3# SET Port Monitor 6 from 1,3 # SET Port Monitor 7 from 2,4Limits of Liability Customer ServiceInternet Warranty Datacom Systems Inc