Avaya G350 manual Attach ground conductors, Inserting a media module

Page 27

Installing the Avaya G350 Media Gateway

Step 3: Attach ground conductors

Figure 6: Inserting a media module

4Apply firm pressure to engage the connectors.

The media module connector has different length pins. The long pins will engage first to provide grounding. Medium length and short pins will provide power and signal.

5Lock the media module into the chassis by tightening the spring-loaded captive screws on the front of the module.

!DANGER:

To prevent access to electrical hazards by unauthorized personnel and to ensure continued compliance to international radiated emissions requirements, all captive screws must be securely tightened such that they cannot be loosened without the use of a tool.

! WARNING:

After you have connected telephones to the various media modules, be sure to add circuit protection to the lines (See Step 4: Install circuit protection on page 49).

Step 3: Attach ground conductors

To assure safe installation and operation, carefully read all requirements, recommendations and instructions. Pay special attention to all CAUTION, WARNING, and DANGER statements.

! WARNING:

System grounding must comply with the general rules for grounding provided in Article 250 of the National Electrical Code (NEC), National Fire Protection Agency (NFPA) 70, or the applicable electrical code in the country of installation.

Installation of the G350 Media Gateway

27

December 2003

 

Image 27
Contents Installation of the Avaya G350 Media Gateway Copyright 2003, Avaya Inc All Rights Reserved SOC/REN Declarations of Conformity Contents Preparing for configuration Technical specifications Installation of the G350 Media Gateway Audience Downloading this book and updates from the WebAbout this book OverviewSecurity Alert Safety labels and security alert labelsWithin the US Related resourcesTechnical assistance TrademarksSending us comments Installation workflows Full installationBefore you start Installation of a staged G350 Gathering informationStaging Unpacking Environmental Verification Site requirementsRequired equipment Installation of the G350 Media Gateway Installing the Avaya G350 Media Gateway Mount the G350 chassisMounting the G350 in a rack Affixing a mounting bracket to the front of the G350 To mount the G350 in the rack To attach each mounting bracket to the G350To affix the feet Mounting the G350 on a wallPlacing the G350 on a table To affix brackets to the G350 for wall mountingInstall the media modules Combination limitationsAllocating slots G350 front panel ports and slots To insert the S8300 Media Server module Inserting the S8300 Media Server moduleTo insert a media module Inserting media modulesInserting a media module Attach ground conductorsGeneral grounding requirements Approved grounds To attach the ground wires Connect the safety groundTo connect power to the G350 Connect power to the G350Installation of the G350 Media Gateway Prepare configuration equipment Preparing for configurationPreparing a G350 without an S8300 for configuration Installation of the G350 Media Gateway December Preparing a G350 with an S8300 for configuration To connect and enable the modem Connecting the USB modemInstallation of the G350 Media Gateway Installation of the G350 Media Gateway December Assisting a combined remote and on-site configuration Assist the configurationAssisting a remote configuration Assisting an on-site configurationAssisting an off-site configuration staging Installation of the G350 Media Gateway Connect the network Connecting devicesTo connect an IP telephone Connect IP telephonesConnecting an analog telephone Connect non-IP telephones and trunksTo connect an analog telephone To connect a DCP telephone Connecting a DCP telephoneTo connect an E1/T1 trunk Connecting an analog trunkConnecting an E1/T1 trunk To connect an analog trunkTo connect an Isdn BRI trunk Connecting an Isdn BRI trunkOver-Voltage and Sneak-Current Protection Install circuit protectionConnecting the G350 to the WAN Connect to the Wide Area Network WANTo connect the WAN to the G350 Install the Coupled Bonding Conductor Connecting an external router to the G350To install the CBC To install the contact closure Install the Avaya Partner Contact Closure AdjunctTesting trunks After installationTest the installation Testing telephonesLSP failover testing Remove the installation equipmentTechnical specifications G350 Media Gateway specificationsPower Cord Specifications Power Cord Specifications Index Installing the G350 chassis Installation of the G350 Media Gateway December Installation of the G350 Media Gateway