Avaya Technical specifications, G350 Media Gateway specifications, Power Cord Specifications

Page 55

Technical specifications

G350 Media Gateway specifications

A Technical specifications

This appendix provides technical specifications for the G350 and for compatible power cords.

G350 Media Gateway specifications

The table of technical specifications provides detailed information on the physical dimensions and tolerances of the G350 Media Gateway.

Table 2: G350 Media Gateway specifications

Description

Value

Height

5.25 in. (133.3 mm)

 

 

Width

19 in. (482.6 mm)

 

 

Depth

15.75 in. (400 mm)

 

 

Weight of empty chassis

9-10 kg

 

 

Ambient working temperature

0-40°C

 

 

Operation altitude

up to 2000 m

 

 

Front Clearance

12 in. (30 cm)

 

 

Rear Clearance

18 in. (45 cm)

 

 

Humidity

20-60% relative humidity

 

 

Power Cord Specifications

Following are specifications for power cords suitable for use with the G350:

For North America: The cordset must be UL Listed/CSA Certified, 16 AWG, 3-conductor (3rd wire ground), type SJT. One end is to be terminated to an IEC 60320, sheet C13 type connector rated 10A, 250V. The other end is to be terminated to either a NEMA 5-15P attachment plug for nominal 125V applications or a NEMA 6-15P attachment plug for nominal 250V applications.

For Outside North America: The cord must be VDE Certified or Harmonized (HAR), rated 250V, 3- conductor (3rd wire ground), 1.0 mm2 minimum conductor size. The cord is to be terminated at one end to a VDE Certified/CE Marked IEC 60320, sheet C13 type connector rated 10A, 250V and the other end to a 3-conductor grounding type attachment plug rated at a minimum of 10A, 250V and a configuration specific for the region/country in which it will be used. The attachment plug must bear the safety agency certifications mark(s) for the region/country of installation.

Installation of the G350 Media Gateway

55

December 2003

 

Image 55
Contents Installation of the Avaya G350 Media Gateway Copyright 2003, Avaya Inc All Rights Reserved SOC/REN Declarations of Conformity Contents Preparing for configuration Technical specifications Installation of the G350 Media Gateway Audience Downloading this book and updates from the WebAbout this book OverviewSecurity Alert Safety labels and security alert labelsWithin the US Related resourcesTechnical assistance TrademarksSending us comments Full installation Installation workflowsBefore you start Gathering information Installation of a staged G350Staging Unpacking Environmental Verification Site requirementsRequired equipment Installation of the G350 Media Gateway Mount the G350 chassis Installing the Avaya G350 Media GatewayMounting the G350 in a rack Affixing a mounting bracket to the front of the G350 To mount the G350 in the rack To attach each mounting bracket to the G350To affix the feet Mounting the G350 on a wallPlacing the G350 on a table To affix brackets to the G350 for wall mountingCombination limitations Install the media modulesAllocating slots G350 front panel ports and slots To insert the S8300 Media Server module Inserting the S8300 Media Server moduleTo insert a media module Inserting media modulesInserting a media module Attach ground conductorsGeneral grounding requirements Approved grounds To attach the ground wires Connect the safety groundTo connect power to the G350 Connect power to the G350Installation of the G350 Media Gateway Prepare configuration equipment Preparing for configurationPreparing a G350 without an S8300 for configuration Installation of the G350 Media Gateway December Preparing a G350 with an S8300 for configuration To connect and enable the modem Connecting the USB modemInstallation of the G350 Media Gateway Installation of the G350 Media Gateway December Assisting a combined remote and on-site configuration Assist the configurationAssisting a remote configuration Assisting an on-site configurationAssisting an off-site configuration staging Installation of the G350 Media Gateway Connect the network Connecting devicesTo connect an IP telephone Connect IP telephonesConnect non-IP telephones and trunks Connecting an analog telephoneTo connect an analog telephone To connect a DCP telephone Connecting a DCP telephoneTo connect an E1/T1 trunk Connecting an analog trunkConnecting an E1/T1 trunk To connect an analog trunkTo connect an Isdn BRI trunk Connecting an Isdn BRI trunkOver-Voltage and Sneak-Current Protection Install circuit protectionConnect to the Wide Area Network WAN Connecting the G350 to the WANTo connect the WAN to the G350 Connecting an external router to the G350 Install the Coupled Bonding ConductorTo install the CBC To install the contact closure Install the Avaya Partner Contact Closure AdjunctTesting trunks After installationTest the installation Testing telephonesLSP failover testing Remove the installation equipmentG350 Media Gateway specifications Technical specificationsPower Cord Specifications Power Cord Specifications Index Installing the G350 chassis Installation of the G350 Media Gateway December Installation of the G350 Media Gateway