Axis Communications A1001 user manual Overview

Page 11

AXIS A1001 Network Door Controller & AXIS Entry Manager

Access the Product

The Overview Page

The Overview page in AXIS Entry Manager shows information about the door controller’s name, MAC address, IP address, and firmware version. It also enables you to identify the door controller on the network or in the system.

The first time you access the Axis product, the Overview page will prompt you to configure the hardware, to set date and time, to configure the network settings, and to configure the door controller as part of a system or as a standalone unit. For more information about configuring the system, see Configuration – Step by Step on page 12.

To return to the Overview page from the product’s other webpages, click Overview in the menu bar.

11

Image 11
Contents Axis A1001 Network Door Controller & Axis Entry Manager Trademark Acknowledgments About this DocumentLiability Intellectual Property Rights Equipment ModificationsLearn More SupportAxis A1001 Network Door Controller & Axis Entry Manager Front and back Hardware OverviewInterface External power inputsPower outputs Color Indication LED IndicatorsLED indicators, buttons and other hardware Power Connector Connectors and ButtonsExternal Power Inputs For technical specifications, seeButtons and Other Hardware Power OutputsStart a browser Chrome, Internet Explorer, Firefox, Safari Access from a BrowserAccess from the Internet Set the Root PasswordOverview Select a Language Configuration Step by StepTo import a hardware configuration file Configure the HardwareImport a Hardware Configuration File Export a Hardware Configuration FileMotorized locks must be configured as secondary locks Create a New Hardware ConfigurationConfigure Locks and Door Monitors To create a new hardware configuration from the beginningLock Options Following reader options are available Configure Readers and REX DevicesUse Supervised Inputs Reader and REX Device OptionsVerification Controls Verify the Hardware ConnectionsSet the Date and Time Get the Date and Time from the Computer Configure the Network SettingsSet the Date and Time Manually Go to Setup Configure Card Formats Configure Card FormatsBasic TCP/IP Settings To enable card formatsField Maps Card Format DescriptionsConnected Door Controllers List Manage Network Door ControllersDoor Controller System Status Connected Door Controllers in the SystemRemove Door Controllers from the System Click Reset hardware configurationIP address MAC address Maintenance Instructions Choose a Workflow Access ManagementAbout Users Access Schedule Types Create and Edit Access SchedulesAdd Schedule Items Group Credentials Go to Access Management Groups tab, click Add new groupCreate and Edit Groups Manage DoorsClick Add scheduled unlock Identification TypesAdd Scheduled Unlock States Manual Door Actions Go to Access ManagementCreate and Edit Users Use Manual Door ActionsFirst name required Last name User CredentialsImport Users Following credentials are available for usersExport Users Example Access Schedule CombinationsCreate a Subtraction schedule called Nights & weekends Event Log Filters View the Alarm LogConfigure the Event and Alarm Logs View the Event LogEvent Log Options Set Up Action RulesAlarm Log Options Go to Events Action Rules and click Add Access PointConfiguration TriggersHardware DoorAdd Recipients ActionsFollowing recipients are available Set Up Email RecipientsCreate Schedules Recipient TypesBeeper pattern State Dual LED Single LED Set Up RecurrencesReader Feedback Event WiegandClick Print selected columns View, Print, and Export ReportsReport Types Click View and printIP Address Filter To enable Https on the Axis productSecurity UsersCertificates To allow the product to access a network protected by IeeeIeee Create a self-signed certificate as described above Click Install certificate and upload the certificateDate & Time NetworkLinux/Unix example Assign IP Address Using ARP/PingARP/Ping Linux/Unix syntaxNTP Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service DNS ConfigurationLink-Local IPv4 Address Host Name ConfigurationInformation, see the online help QoS Quality of ServicePorts & Devices MaintenanceLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsAdvanced ScriptingUNIX/Linux, type the following from the command line Upgrade the FirmwareEmergency Recovery Procedure Firmware To upgrade the product’s firmwareProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserHardware failure Status and Network indicator LEDs are flashing red rapidlyAxis A1001 Network Door Controller Weight Function/group Specifications General CasingPower ConnectorsAxis Entry Manager Connectors Function Pin Reader Data ConnectorReader I/O Connector Function Pin SpecificationsPower Connector Door ConnectorAuxiliary Connector Tampering Alarm Pin Header Network ConnectorPower Lock Connector Power & Relay ConnectorBack tampering alarm Connection DiagramsSupervised Inputs M5.7
Related manuals
Manual 20 pages 40.35 Kb