Axis Communications A1001 user manual Axis Entry Manager

Page 56

AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

AXIS Entry Manager

Function/group

Item

Specifications

 

 

 

 

Models

AXIS A1001 with built-in web-based software

 

 

 

Door controller

Readers

Up to 2 readers per controller1 (Wiegand, RS485 (OSDP) with supported card formats

 

Controllers

1–33

 

 

 

 

Credentials

Up to 400

 

 

 

 

Event history

30 000 First in First out (FIFO) per system

 

 

 

Digital I/O

I/O interface

Reader I/0: DC output: 2x 12 V DC output max 300 mA; 2x 4 configurable

 

 

inputs/outputs, (digital input: 0 to max 40 V DC, digital output: 0 to max 40 V DC,

 

 

open drain, max 100 mA)

 

 

Reader data: RS485 full duplex, RS485 half duplex, Wiegand

 

 

Auxiliary: 1x 3.3 V DC output, max 100 mA, 2x configurable inputs/output (digital

 

 

input: 0 to max 40 V DC, digital output: 0 to max 40 V DC, open drain, max 100 mA)

 

 

Door connectors: 2x 2 input for door monitors and REX (digital input: 0 to

 

 

max 40 V DC)

 

 

 

 

I/O functionality

Preconfigured for readers and door monitors, Input trigger, Output toggle/pulse

 

 

 

Network

Security

Password protection, IP address filtering, HTTPS2 encryption, IEEE 802.1X network

 

 

access control, digest authentication, user access log

 

 

 

 

Supported protocols

IPv4, HTTP, HTTPS2, TLS2, QoS layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP,

 

 

SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP,

 

 

DHCP, ARP, SOCKS

 

 

 

Events & Alarms

Tamper detection

Removal of unit cover/tamper front

 

 

Removal of unit from wall/tamper back

 

 

Reader tamper

 

 

 

 

Event log

Configurable by time and topic, Alarm acknowledgement

 

 

 

 

Event actions

Notification via email, HTTP and TCP, External output port, Status LED

 

 

 

 

Event triggers

Access Point: Access point enabled

 

 

Configuration: Access point changed, Access point removed, Door changed, Door

 

 

removed

 

 

Door: Door alarm, Door double-lock monitor, Door lock monitor, Door mode, Door

 

 

monitor, Door warning

 

 

Event Logger: Alarm

 

 

Hardware: Casing open, Network, peer connection

 

 

Input Signal Digital input port, Manual trigger, Virtual inputs

 

 

Schedule: Interval, Pulse

 

 

System: System ready

 

 

Time: Recurrence, Use schedule

 

 

 

System features

Access schedules

Unlimited

 

 

 

 

Installation &

Configuration wizard, configuration verification, Color-coded connectors, I/O

 

Configuration

assignment print-out, Automatic controller discovery, Instant feedback of missing

 

 

configuration data

 

 

 

 

Administration

Drag-and-drop operation with flexible assignment of doors and user groups,

 

 

Retrieve credentials from reader, Manual access/lock/unlock, Import of users

 

 

 

 

Languages

English, German, French, Spanish, Italian

 

 

 

56

Image 56
Contents Axis A1001 Network Door Controller & Axis Entry Manager About this Document LiabilityIntellectual Property Rights Equipment Modifications Trademark AcknowledgmentsSupport Learn MoreAxis A1001 Network Door Controller & Axis Entry Manager Hardware Overview Front and backInterface External power inputsPower outputs Color Indication LED IndicatorsLED indicators, buttons and other hardware Connectors and Buttons External Power InputsFor technical specifications, see Power ConnectorPower Outputs Buttons and Other HardwareAccess from a Browser Access from the InternetSet the Root Password Start a browser Chrome, Internet Explorer, Firefox, SafariOverview Configuration Step by Step Select a LanguageConfigure the Hardware Import a Hardware Configuration FileExport a Hardware Configuration File To import a hardware configuration fileCreate a New Hardware Configuration Configure Locks and Door MonitorsTo create a new hardware configuration from the beginning Motorized locks must be configured as secondary locksLock Options Configure Readers and REX Devices Use Supervised InputsReader and REX Device Options Following reader options are availableVerification Controls Verify the Hardware ConnectionsSet the Date and Time Get the Date and Time from the Computer Configure the Network SettingsSet the Date and Time Manually Configure Card Formats Basic TCP/IP SettingsTo enable card formats Go to Setup Configure Card FormatsCard Format Descriptions Field MapsManage Network Door Controllers Door Controller System StatusConnected Door Controllers in the System Connected Door Controllers ListRemove Door Controllers from the System Click Reset hardware configurationIP address MAC address Maintenance Instructions Choose a Workflow Access ManagementAbout Users Create and Edit Access Schedules Access Schedule TypesAdd Schedule Items Go to Access Management Groups tab, click Add new group Create and Edit GroupsManage Doors Group CredentialsClick Add scheduled unlock Identification TypesAdd Scheduled Unlock States Go to Access Management Create and Edit UsersUse Manual Door Actions Manual Door ActionsUser Credentials Import UsersFollowing credentials are available for users First name required Last nameExample Access Schedule Combinations Export UsersCreate a Subtraction schedule called Nights & weekends View the Alarm Log Configure the Event and Alarm LogsView the Event Log Event Log FiltersEvent Log Options Set Up Action RulesAlarm Log Options Access Point ConfigurationTriggers Go to Events Action Rules and click AddDoor HardwareActions Add RecipientsSet Up Email Recipients Create SchedulesRecipient Types Following recipients are availableSet Up Recurrences Reader FeedbackEvent Wiegand Beeper pattern State Dual LED Single LEDView, Print, and Export Reports Report TypesClick View and print Click Print selected columnsTo enable Https on the Axis product SecurityUsers IP Address FilterCertificates To allow the product to access a network protected by IeeeIeee Click Install certificate and upload the certificate Date & TimeNetwork Create a self-signed certificate as described aboveAssign IP Address Using ARP/Ping ARP/PingLinux/Unix syntax Linux/Unix exampleAdvanced TCP/IP Settings Axis Internet Dynamic DNS ServiceDNS Configuration NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressQoS Quality of Service Information, see the online helpMaintenance Ports & DevicesSupport Support OverviewSystem Overview Logs & ReportsReset to Factory Default Settings AdvancedScripting File UploadUpgrade the Firmware Emergency Recovery ProcedureFirmware To upgrade the product’s firmware UNIX/Linux, type the following from the command lineSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Hardware failureAxis A1001 Network Door Controller Function/group Specifications General Casing PowerConnectors WeightAxis Entry Manager Connectors Reader Data Connector Reader I/O ConnectorFunction Pin Specifications Function PinPower Connector Door ConnectorAuxiliary Connector Network Connector Power Lock ConnectorPower & Relay Connector Tampering Alarm Pin HeaderConnection Diagrams Back tampering alarmSupervised Inputs M5.7
Related manuals