Axis Communications A1001 user manual Connectors

Page 57

AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Function/group

Item

Specifications

 

 

 

General

Casing

Plastic

 

 

 

 

Software

Configuration and basic access control management through Internet Explorer,

 

 

Firefox, Chrome, or Safari

 

 

 

 

Memory

256 MB RAM, 4 Gbit Flash

 

 

 

 

Power

Power in: 10–30 V DC, max 26 W or Power over Ethernet

 

 

IEEE 802.3af/802.3at Type 1 Class 3

 

 

Power out & relay: 1x 12 V DC, max 500 mA 1x solid state relay 30 V DC,

 

 

max 700 mA

 

 

Power out lock: 2x 12 V DC, max 500 mA1

 

Connectors

RJ45 10BASE-T/100BASE-TX

 

 

Terminal blocks: DC power, 10 Inputs/Outputs, RS485/Wiegand, Relay

 

 

Cable size for connectors: CSA: AWG 28–16, CUL/UL: AWG 30–14

 

 

 

 

Operating conditions

0 °C to 50 °C (32 °F to 122 °F)

 

 

Humidity 20–85% RH (non-condensing)

 

 

 

 

Approvals

EN 55022 Class B, EN 50130-4, EN 61000-3-2, EN 61000-3-3, EN 55024,

 

 

EN 61000-6-1, EN 61000-6-2FCC Part 15 Subpart B Class B

 

 

ICES-003 Class B

 

 

C-tick AS/NZS CISPR22 Class B

 

 

VCCI Class B

 

 

IEC/EN/UL 60950-1, UL 294, UL 2043, EN 50581

 

 

 

 

Dimensions (HxWxD)

45.5 x 180 x 180 mm (1.8 x 7.1 x 7.1 in)

 

 

 

 

Weight

500 g (1.1 lb)

 

 

 

 

Included accessories

Connector kit, Cable ties, Installation Guide

 

 

 

 

Warranty

Axis 3-year warranty with possibility to extend up to 5 years, see

 

 

www.axis.com/warranty

 

 

 

 

Optional accessories

AXIS T8120 Midspan 15 W

 

 

AXIS T8128 PoE Splitter 24 V (requires 30 W midspan)

 

 

AXIS T8129 PoE Extender Mains adaptor 24 V DC

 

 

AXIS T98A15-VE Surveillance Cabinet3

1.Power consumption dependent; max load for readers and other equipment is 7.5 W with PoE and 14 W with 10–30 V DC.

2.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/), and cryptographic software written by Eric Young (eay@cryptsoft.com)

3.In outdoor installations combining AXIS A1001 and AXIS T98A15-VE, the allowed maximum voltage is 30 V DC.

Connectors

For information about the connectors’ positions, see Hardware Overview on page 5 .

For connection diagrams and information about the hardware pin chart generated through the hardware configuration, see Connection Diagrams on page 61 and Configure the Hardware on page 13.

The following section describes the connectors’ technical specifications.

57

Image 57
Contents Axis A1001 Network Door Controller & Axis Entry Manager Liability About this DocumentIntellectual Property Rights Equipment Modifications Trademark AcknowledgmentsLearn More SupportAxis A1001 Network Door Controller & Axis Entry Manager Front and back Hardware OverviewExternal power inputs Power outputsInterface LED Indicators LED indicators, buttons and other hardwareColor Indication External Power Inputs Connectors and ButtonsFor technical specifications, see Power ConnectorButtons and Other Hardware Power OutputsAccess from the Internet Access from a BrowserSet the Root Password Start a browser Chrome, Internet Explorer, Firefox, SafariOverview Select a Language Configuration Step by StepImport a Hardware Configuration File Configure the HardwareExport a Hardware Configuration File To import a hardware configuration fileConfigure Locks and Door Monitors Create a New Hardware ConfigurationTo create a new hardware configuration from the beginning Motorized locks must be configured as secondary locksLock Options Use Supervised Inputs Configure Readers and REX DevicesReader and REX Device Options Following reader options are availableVerify the Hardware Connections Set the Date and TimeVerification Controls Configure the Network Settings Set the Date and Time ManuallyGet the Date and Time from the Computer Basic TCP/IP Settings Configure Card FormatsTo enable card formats Go to Setup Configure Card FormatsField Maps Card Format DescriptionsDoor Controller System Status Manage Network Door ControllersConnected Door Controllers in the System Connected Door Controllers ListClick Reset hardware configuration IP address MAC addressRemove Door Controllers from the System Maintenance Instructions Access Management About UsersChoose a Workflow Access Schedule Types Create and Edit Access SchedulesAdd Schedule Items Create and Edit Groups Go to Access Management Groups tab, click Add new groupManage Doors Group CredentialsIdentification Types Add Scheduled Unlock StatesClick Add scheduled unlock Create and Edit Users Go to Access ManagementUse Manual Door Actions Manual Door ActionsImport Users User CredentialsFollowing credentials are available for users First name required Last nameExport Users Example Access Schedule CombinationsCreate a Subtraction schedule called Nights & weekends Configure the Event and Alarm Logs View the Alarm LogView the Event Log Event Log FiltersSet Up Action Rules Alarm Log OptionsEvent Log Options Configuration Access PointTriggers Go to Events Action Rules and click AddHardware DoorAdd Recipients ActionsCreate Schedules Set Up Email RecipientsRecipient Types Following recipients are availableReader Feedback Set Up RecurrencesEvent Wiegand Beeper pattern State Dual LED Single LEDReport Types View, Print, and Export ReportsClick View and print Click Print selected columnsSecurity To enable Https on the Axis productUsers IP Address FilterTo allow the product to access a network protected by Ieee IeeeCertificates Date & Time Click Install certificate and upload the certificateNetwork Create a self-signed certificate as described aboveARP/Ping Assign IP Address Using ARP/PingLinux/Unix syntax Linux/Unix exampleAxis Internet Dynamic DNS Service Advanced TCP/IP SettingsDNS Configuration NTP ConfigurationLink-Local IPv4 Address Host Name ConfigurationInformation, see the online help QoS Quality of ServicePorts & Devices MaintenanceSupport Overview SupportSystem Overview Logs & ReportsAdvanced Reset to Factory Default SettingsScripting File UploadEmergency Recovery Procedure Upgrade the FirmwareFirmware To upgrade the product’s firmware UNIX/Linux, type the following from the command lineProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyHardware failure Status and Network indicator LEDs are flashing red rapidly Axis A1001 Network Door Controller Power Function/group Specifications General CasingConnectors WeightAxis Entry Manager Connectors Reader I/O Connector Reader Data ConnectorFunction Pin Specifications Function PinDoor Connector Auxiliary ConnectorPower Connector Power Lock Connector Network ConnectorPower & Relay Connector Tampering Alarm Pin HeaderBack tampering alarm Connection DiagramsSupervised Inputs M5.7
Related manuals
Manual 20 pages 40.35 Kb