Axis Communications A1001 user manual Door Connector, Auxiliary Connector, Power Connector

Page 59

AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Door Connector

Two 4-pin terminal blocks for door monitoring devices (digital input).

All door input pins can be supervised. If the connection is interrupted, an alarm is triggered. To use supervised inputs, install end of line resistors. Use the connection diagram for supervised inputs. See page 62.

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1, 3

 

0 V DC

 

 

 

 

Input

2, 4

For communicating with door monitor.

0 to max 40 V DC

 

 

Digital input — Connect to pin 1 or 3 respectively to

 

 

 

activate, or leave floating (unconnected) to deactivate.

 

 

 

Note: This pin can only be used for input.

 

 

 

 

 

Auxiliary Connector

4-pin configurable I/O terminal block for:

• Auxiliary power (DC output)

• Digital Input

Digital Output

0 V DC (-)

For an example connection diagram, see Connection Diagrams on page 61.

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1

 

0 V DC

 

 

 

 

DC output

2

For powering auxiliary equipment.

3.3 V DC

 

 

Note: This pin can only be used as power out.

Max load = 100 mA

 

 

 

 

Configurable

3–4

Digital input — Connect to pin 1 to activate, or leave

0 to max 40 V DC

(Input or Output)

 

floating (unconnected) to deactivate.

 

 

 

 

 

 

 

Digital output — Connect to pin 1 to activate, or leave

0 to max 40 V DC, open drain,

 

 

floating (unconnected) to deactivate. If used with an

100 mA

 

 

inductive load, e.g. a relay, a diode must be connected

 

 

 

in parallel with the load, for protection against voltage

 

 

 

transients.

 

 

 

 

 

Power Connector

2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a rated output power limited to 100 W or a rated output current limited to 5 A.

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1

 

0 V DC

 

 

 

 

DC input

2

For powering controller when not using Power over

10–30 V DC, max 26 W

 

 

Ethernet.

Max load on outputs = 14 W

 

 

Note: This pin can only be used as power in.

 

 

 

 

 

59

Image 59
Contents Axis A1001 Network Door Controller & Axis Entry Manager Trademark Acknowledgments About this DocumentLiability Intellectual Property Rights Equipment ModificationsLearn More SupportAxis A1001 Network Door Controller & Axis Entry Manager Front and back Hardware OverviewInterface External power inputsPower outputs Color Indication LED IndicatorsLED indicators, buttons and other hardware Power Connector Connectors and ButtonsExternal Power Inputs For technical specifications, seeButtons and Other Hardware Power OutputsStart a browser Chrome, Internet Explorer, Firefox, Safari Access from a BrowserAccess from the Internet Set the Root PasswordOverview Select a Language Configuration Step by StepTo import a hardware configuration file Configure the HardwareImport a Hardware Configuration File Export a Hardware Configuration FileMotorized locks must be configured as secondary locks Create a New Hardware ConfigurationConfigure Locks and Door Monitors To create a new hardware configuration from the beginningLock Options Following reader options are available Configure Readers and REX DevicesUse Supervised Inputs Reader and REX Device OptionsVerification Controls Verify the Hardware ConnectionsSet the Date and Time Get the Date and Time from the Computer Configure the Network SettingsSet the Date and Time Manually Go to Setup Configure Card Formats Configure Card FormatsBasic TCP/IP Settings To enable card formatsField Maps Card Format DescriptionsConnected Door Controllers List Manage Network Door ControllersDoor Controller System Status Connected Door Controllers in the SystemRemove Door Controllers from the System Click Reset hardware configurationIP address MAC address Maintenance Instructions Choose a Workflow Access ManagementAbout Users Access Schedule Types Create and Edit Access SchedulesAdd Schedule Items Group Credentials Go to Access Management Groups tab, click Add new groupCreate and Edit Groups Manage DoorsClick Add scheduled unlock Identification TypesAdd Scheduled Unlock States Manual Door Actions Go to Access ManagementCreate and Edit Users Use Manual Door ActionsFirst name required Last name User CredentialsImport Users Following credentials are available for usersExport Users Example Access Schedule CombinationsCreate a Subtraction schedule called Nights & weekends Event Log Filters View the Alarm LogConfigure the Event and Alarm Logs View the Event LogEvent Log Options Set Up Action RulesAlarm Log Options Go to Events Action Rules and click Add Access PointConfiguration TriggersHardware DoorAdd Recipients ActionsFollowing recipients are available Set Up Email RecipientsCreate Schedules Recipient TypesBeeper pattern State Dual LED Single LED Set Up RecurrencesReader Feedback Event WiegandClick Print selected columns View, Print, and Export ReportsReport Types Click View and printIP Address Filter To enable Https on the Axis productSecurity UsersCertificates To allow the product to access a network protected by IeeeIeee Create a self-signed certificate as described above Click Install certificate and upload the certificateDate & Time NetworkLinux/Unix example Assign IP Address Using ARP/PingARP/Ping Linux/Unix syntaxNTP Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service DNS ConfigurationLink-Local IPv4 Address Host Name ConfigurationInformation, see the online help QoS Quality of ServicePorts & Devices MaintenanceLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsAdvanced ScriptingUNIX/Linux, type the following from the command line Upgrade the FirmwareEmergency Recovery Procedure Firmware To upgrade the product’s firmwareProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserHardware failure Status and Network indicator LEDs are flashing red rapidlyAxis A1001 Network Door Controller Weight Function/group Specifications General CasingPower ConnectorsAxis Entry Manager Connectors Function Pin Reader Data ConnectorReader I/O Connector Function Pin SpecificationsPower Connector Door ConnectorAuxiliary Connector Tampering Alarm Pin Header Network ConnectorPower Lock Connector Power & Relay ConnectorBack tampering alarm Connection DiagramsSupervised Inputs M5.7