Axis Communications A1001 IP address MAC address, Remove Door Controllers from the System

Page 22

AXIS A1001 Network Door Controller & AXIS Entry Manager

System Configuration

Name – The user-defined name of the door controller. If the administrator has not set a name when configuring the hardware, the default name will be shown.

IP address

MAC address

Status – The door controller from which you access the system will show status This controller. The other door controllers in the system will show status Online.

To open the webpages of another door controller, click the controller’s IP address.

To update the list, click Refresh the list of controllers.

Add Door Controllers to the System

Important

When pairing door controllers, all access management settings on the added door controller will be deleted and overwritten by the system’s access management settings.

To add a door controller to the system from the list of door controllers:

1.Go to Setup > Manage Network Door Controllers in System.

2.Click Add controllers to system from list.

3.Select the door controller that you wish to add.

4.Click Add.

5.To add more door controllers, repeat the steps above.

To add a door controller to the system by its known IP address or MAC address:

1.Go to Manage Devices.

2.Click Add controller to system by IP or MAC address.

3.Enter the IP address or MAC address.

4.Click Add.

5.To add more door controllers, repeat the steps above.

When the pairing is completed, all users, doors, schedules, and groups are shared by all door controllers in the system.

To update the list, click Refresh list of controllers.

Remove Door Controllers from the System

Important

Before removing a door controller from the system, reset its hardware configuration. If you skip this step, all doors related to the removed door controller will remain in the system and cannot be deleted.

When removing a door controller from a two-controller system, both door controllers automatically switch to standalone mode.

To remove a door controller from the system:

1.Access the system through the door controller that you want to remove and go to Setup > Hardware Configuration .

2.Click Reset hardware configuration .

22

Image 22
Contents Axis A1001 Network Door Controller & Axis Entry Manager Intellectual Property Rights Equipment Modifications About this DocumentLiability Trademark AcknowledgmentsSupport Learn MoreAxis A1001 Network Door Controller & Axis Entry Manager Hardware Overview Front and backPower outputs External power inputsInterface LED indicators, buttons and other hardware LED IndicatorsColor Indication For technical specifications, see Connectors and ButtonsExternal Power Inputs Power ConnectorPower Outputs Buttons and Other HardwareSet the Root Password Access from a BrowserAccess from the Internet Start a browser Chrome, Internet Explorer, Firefox, SafariOverview Configuration Step by Step Select a LanguageExport a Hardware Configuration File Configure the HardwareImport a Hardware Configuration File To import a hardware configuration fileTo create a new hardware configuration from the beginning Create a New Hardware ConfigurationConfigure Locks and Door Monitors Motorized locks must be configured as secondary locksLock Options Reader and REX Device Options Configure Readers and REX DevicesUse Supervised Inputs Following reader options are availableSet the Date and Time Verify the Hardware ConnectionsVerification Controls Set the Date and Time Manually Configure the Network SettingsGet the Date and Time from the Computer To enable card formats Configure Card Formats Basic TCP/IP Settings Go to Setup Configure Card FormatsCard Format Descriptions Field MapsConnected Door Controllers in the System Manage Network Door ControllersDoor Controller System Status Connected Door Controllers ListIP address MAC address Click Reset hardware configurationRemove Door Controllers from the System Maintenance Instructions About Users Access ManagementChoose a Workflow Create and Edit Access Schedules Access Schedule TypesAdd Schedule Items Manage Doors Go to Access Management Groups tab, click Add new groupCreate and Edit Groups Group CredentialsAdd Scheduled Unlock States Identification TypesClick Add scheduled unlock Use Manual Door Actions Go to Access ManagementCreate and Edit Users Manual Door ActionsFollowing credentials are available for users User CredentialsImport Users First name required Last nameExample Access Schedule Combinations Export UsersCreate a Subtraction schedule called Nights & weekends View the Event Log View the Alarm LogConfigure the Event and Alarm Logs Event Log FiltersAlarm Log Options Set Up Action RulesEvent Log Options Triggers Access PointConfiguration Go to Events Action Rules and click AddDoor HardwareActions Add RecipientsRecipient Types Set Up Email RecipientsCreate Schedules Following recipients are availableEvent Wiegand Set Up RecurrencesReader Feedback Beeper pattern State Dual LED Single LEDClick View and print View, Print, and Export ReportsReport Types Click Print selected columnsUsers To enable Https on the Axis productSecurity IP Address FilterIeee To allow the product to access a network protected by IeeeCertificates Network Click Install certificate and upload the certificateDate & Time Create a self-signed certificate as described aboveLinux/Unix syntax Assign IP Address Using ARP/PingARP/Ping Linux/Unix exampleDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressQoS Quality of Service Information, see the online helpMaintenance Ports & DevicesSystem Overview SupportSupport Overview Logs & ReportsScripting Reset to Factory Default SettingsAdvanced File UploadFirmware To upgrade the product’s firmware Upgrade the FirmwareEmergency Recovery Procedure UNIX/Linux, type the following from the command lineProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Hardware failureAxis A1001 Network Door Controller Connectors Function/group Specifications General CasingPower WeightAxis Entry Manager Connectors Function Pin Specifications Reader Data ConnectorReader I/O Connector Function PinAuxiliary Connector Door ConnectorPower Connector Power & Relay Connector Network ConnectorPower Lock Connector Tampering Alarm Pin HeaderConnection Diagrams Back tampering alarmSupervised Inputs M5.7