Axis Communications A1001 user manual Assign IP Address Using ARP/Ping, Linux/Unix syntax

Page 44

AXIS A1001 Network Door Controller & AXIS Entry Manager

System Options

If DHCP is enabled and the product cannot be accessed, run AXIS IP Utility to search the network for connected Axis products, or reset the product to the factory default settings and then perform the installation again. For information about how to reset to factory default, see page 50.

ARP/Ping

The product’s IP address can be assigned using ARP and Ping. For instructions, see Assign IP Address Using ARP/Ping on page 44.

The ARP/Ping service is enabled by default but is automatically disabled two minutes after the product is started, or as soon as an IP address is assigned. To re-assign IP address using ARP/Ping, the product must be restarted to enable ARP/Ping for an additional two minutes.

To disable the service, go to Setup > Additional Controller Configuration > System Options > Network > TCP/IP > Basic and clear the option Enable ARP/Ping setting of IP address.

Pinging the product is still possible when the service is disabled.

Assign IP Address Using ARP/Ping

The product's IP address can be assigned using ARP/Ping. The command must be issued within 2 minutes of connecting power.

1.Acquire a free static IP address on the same network segment as the computer.

2.Locate the serial number (S/N) on the product label.

3.Open a command prompt and enter the following commands:

Linux/Unix syntax

arp -s <IP address> <serial number> temp ping -s 408 <IP address>

Linux/Unix example

arp -s 192.168.0.125 00:40:8c:18:10:00 temp ping -s 408 192.168.0.125

Windows syntax (this may require that you run the command prompt as an administrator)

arp -s <IP address> <serial number> ping -l 408 -t <IP address>

Windows example (this may require that you run the command prompt as an administrator)

arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125

4.Check that the network cable is connected and then restart the product by disconnecting and reconnecting power.

5.Close the command prompt when the product responds with Reply from 192.168.0.125:... or similar.

6.Open a browser and type http://<IP address> in the Location/Address field.

For other methods of assigning the IP address, you may find the document Assign an IP Address and Access the Video Stream on Axis Support web at www.axis.com/techsup useful.

Note

To open a command prompt in Windows, open the Start menu and type cmd in the Run/Search field.

To use the ARP command in Windows 8/Windows 7/Windows Vista, right-click the command prompt icon and select Run as administrator.

To open a command prompt in Mac OS X, open the Terminal utility from Application > Utilities.

44

Image 44
Contents Axis A1001 Network Door Controller & Axis Entry Manager About this Document LiabilityIntellectual Property Rights Equipment Modifications Trademark AcknowledgmentsSupport Learn MoreAxis A1001 Network Door Controller & Axis Entry Manager Hardware Overview Front and backInterface External power inputsPower outputs Color Indication LED IndicatorsLED indicators, buttons and other hardware Connectors and Buttons External Power InputsFor technical specifications, see Power ConnectorPower Outputs Buttons and Other HardwareAccess from a Browser Access from the InternetSet the Root Password Start a browser Chrome, Internet Explorer, Firefox, SafariOverview Configuration Step by Step Select a LanguageConfigure the Hardware Import a Hardware Configuration FileExport a Hardware Configuration File To import a hardware configuration fileCreate a New Hardware Configuration Configure Locks and Door MonitorsTo create a new hardware configuration from the beginning Motorized locks must be configured as secondary locksLock Options Configure Readers and REX Devices Use Supervised InputsReader and REX Device Options Following reader options are availableVerification Controls Verify the Hardware ConnectionsSet the Date and Time Get the Date and Time from the Computer Configure the Network SettingsSet the Date and Time Manually Configure Card Formats Basic TCP/IP SettingsTo enable card formats Go to Setup Configure Card FormatsCard Format Descriptions Field MapsManage Network Door Controllers Door Controller System StatusConnected Door Controllers in the System Connected Door Controllers ListRemove Door Controllers from the System Click Reset hardware configurationIP address MAC address Maintenance Instructions Choose a Workflow Access ManagementAbout Users Create and Edit Access Schedules Access Schedule TypesAdd Schedule Items Go to Access Management Groups tab, click Add new group Create and Edit GroupsManage Doors Group CredentialsClick Add scheduled unlock Identification TypesAdd Scheduled Unlock States Go to Access Management Create and Edit UsersUse Manual Door Actions Manual Door ActionsUser Credentials Import UsersFollowing credentials are available for users First name required Last nameExample Access Schedule Combinations Export UsersCreate a Subtraction schedule called Nights & weekends View the Alarm Log Configure the Event and Alarm LogsView the Event Log Event Log FiltersEvent Log Options Set Up Action RulesAlarm Log Options Access Point ConfigurationTriggers Go to Events Action Rules and click AddDoor HardwareActions Add RecipientsSet Up Email Recipients Create SchedulesRecipient Types Following recipients are availableSet Up Recurrences Reader FeedbackEvent Wiegand Beeper pattern State Dual LED Single LEDView, Print, and Export Reports Report TypesClick View and print Click Print selected columnsTo enable Https on the Axis product SecurityUsers IP Address FilterCertificates To allow the product to access a network protected by IeeeIeee Click Install certificate and upload the certificate Date & TimeNetwork Create a self-signed certificate as described aboveAssign IP Address Using ARP/Ping ARP/PingLinux/Unix syntax Linux/Unix exampleAdvanced TCP/IP Settings Axis Internet Dynamic DNS ServiceDNS Configuration NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressQoS Quality of Service Information, see the online helpMaintenance Ports & DevicesSupport Support OverviewSystem Overview Logs & ReportsReset to Factory Default Settings AdvancedScripting File UploadUpgrade the Firmware Emergency Recovery ProcedureFirmware To upgrade the product’s firmware UNIX/Linux, type the following from the command lineSymptoms, Possible Causes and Remedial Actions Problems setting the IP addressProduct cannot be accessed from a browser Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Hardware failureAxis A1001 Network Door Controller Function/group Specifications General Casing PowerConnectors WeightAxis Entry Manager Connectors Reader Data Connector Reader I/O ConnectorFunction Pin Specifications Function PinPower Connector Door ConnectorAuxiliary Connector Network Connector Power Lock ConnectorPower & Relay Connector Tampering Alarm Pin HeaderConnection Diagrams Back tampering alarmSupervised Inputs M5.7
Related manuals
Manual 20 pages 40.35 Kb