Axis Communications A1001 user manual Interface, External power inputs, Power outputs

Page 6

AXIS A1001 Network Door Controller & AXIS Entry Manager

Hardware Overview

I/O interface:

1Reader data connector (READER DATA 1)

10Reader data connector (READER DATA 2)

3Reader I/O connector (READER I/O 1)

8Reader I/O connector (READER I/O 2)

4 Door connector (DOOR IN 1)

7Door connector (DOOR IN 2)

6Auxiliary connector (AUX)

5

Audio connector (AUDIO) (not used)

External power inputs:

2Power connector (DC IN)

12Network connector (PoE)

Power outputs:

9 Power lock connector (LOCK)

11 Power & Relay connector (PWR, RELAY)

6

Image 6
Contents Axis A1001 Network Door Controller & Axis Entry Manager Intellectual Property Rights Equipment Modifications About this DocumentLiability Trademark Acknowledgments Support Learn MoreAxis A1001 Network Door Controller & Axis Entry Manager Hardware Overview Front and backExternal power inputs Power outputsInterface LED Indicators LED indicators, buttons and other hardwareColor Indication For technical specifications, see Connectors and ButtonsExternal Power Inputs Power ConnectorPower Outputs Buttons and Other HardwareSet the Root Password Access from a BrowserAccess from the Internet Start a browser Chrome, Internet Explorer, Firefox, SafariOverview Configuration Step by Step Select a LanguageExport a Hardware Configuration File Configure the HardwareImport a Hardware Configuration File To import a hardware configuration fileTo create a new hardware configuration from the beginning Create a New Hardware ConfigurationConfigure Locks and Door Monitors Motorized locks must be configured as secondary locksLock Options Reader and REX Device Options Configure Readers and REX DevicesUse Supervised Inputs Following reader options are availableVerify the Hardware Connections Set the Date and TimeVerification Controls Configure the Network Settings Set the Date and Time ManuallyGet the Date and Time from the Computer To enable card formats Configure Card FormatsBasic TCP/IP Settings Go to Setup Configure Card FormatsCard Format Descriptions Field MapsConnected Door Controllers in the System Manage Network Door ControllersDoor Controller System Status Connected Door Controllers ListClick Reset hardware configuration IP address MAC addressRemove Door Controllers from the System Maintenance Instructions Access Management About UsersChoose a Workflow Create and Edit Access Schedules Access Schedule TypesAdd Schedule Items Manage Doors Go to Access Management Groups tab, click Add new groupCreate and Edit Groups Group CredentialsIdentification Types Add Scheduled Unlock StatesClick Add scheduled unlock Use Manual Door Actions Go to Access ManagementCreate and Edit Users Manual Door ActionsFollowing credentials are available for users User CredentialsImport Users First name required Last nameExample Access Schedule Combinations Export UsersCreate a Subtraction schedule called Nights & weekends View the Event Log View the Alarm LogConfigure the Event and Alarm Logs Event Log FiltersSet Up Action Rules Alarm Log OptionsEvent Log Options Triggers Access PointConfiguration Go to Events Action Rules and click AddDoor HardwareActions Add RecipientsRecipient Types Set Up Email RecipientsCreate Schedules Following recipients are availableEvent Wiegand Set Up RecurrencesReader Feedback Beeper pattern State Dual LED Single LEDClick View and print View, Print, and Export ReportsReport Types Click Print selected columnsUsers To enable Https on the Axis productSecurity IP Address FilterTo allow the product to access a network protected by Ieee IeeeCertificates Network Click Install certificate and upload the certificateDate & Time Create a self-signed certificate as described aboveLinux/Unix syntax Assign IP Address Using ARP/PingARP/Ping Linux/Unix exampleDNS Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service NTP ConfigurationHost Name Configuration Link-Local IPv4 AddressQoS Quality of Service Information, see the online helpMaintenance Ports & DevicesSystem Overview SupportSupport Overview Logs & ReportsScripting Reset to Factory Default SettingsAdvanced File UploadFirmware To upgrade the product’s firmware Upgrade the FirmwareEmergency Recovery Procedure UNIX/Linux, type the following from the command lineProduct cannot be accessed from a browser Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product is accessible locally but not externallyStatus and Network indicator LEDs are flashing red rapidly Hardware failureAxis A1001 Network Door Controller Connectors Function/group Specifications General CasingPower WeightAxis Entry Manager Connectors Function Pin Specifications Reader Data ConnectorReader I/O Connector Function PinDoor Connector Auxiliary ConnectorPower Connector Power & Relay Connector Network ConnectorPower Lock Connector Tampering Alarm Pin HeaderConnection Diagrams Back tampering alarmSupervised Inputs M5.7
Related manuals
Manual 20 pages 40.35 Kb