Axis Communications A1001 user manual Support, Learn More

Page 3

the product shall be grounded either through a shielded network cable (STP) or other appropriate method.

The power supply used with this product shall fulfill the requirements for Safety Extra Low Voltage (SELV) and Limited Power Source (LPS) according to IEC/EN/UL 60950-1.

Disposal and Recycling

When this product has reached the end of its useful life, dispose of it according to local laws and regulations. For information about your nearest designated collection point, contact your local authority responsible for waste disposal. In accordance with local legislation, penalties may be applicable for incorrect disposal of this waste.

Europe

This symbol means that the product shall not be disposed of together with household or commercial waste. Directive 2012/19/EU on waste electrical and electronic equipment (WEEE) is applicable in the European Union member states. To prevent potential harm to human health and the environment, the product must be disposed of in an approved and environmentally safe recycling process. For information about your nearest designated collection point, contact your local authority responsible for waste disposal. Businesses should contact the product supplier for information about how to dispose of this product correctly.

This product complies with the requirements of Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS).

China

This product complies with the requirements of the legislative act Administration on the Control of Pollution Caused by Electronic Information Products (ACPEIP).

Contact Information

Axis Communications AB

Emdalavägen 14

223 69 Lund

Sweden

Tel: +46 46 272 18 00

Fax: +46 46 13 61 30

www.axis.com

Supported Readers

This list of supported readers is subject to change without notice. Contact your Axis reseller for information about supported readers.

This product is compatible with UL Listed Wiegand access control readers

This product is compatible with the following RS485 access control readers:

AXIS A4011-E Reader

HID iCLASS® RW100: 6101CG40000, 6101CGM0000, 6101CK40000, 6101CK40002, 6101CK40100, 6101CK403C0, 6101CKM0000, 6101CKM0002, 6101CKM0203; RW300: 6111CG40000, 6111CG400C0, 6111CGM0000, 6111CK40000, 6111CK4000Z, 6111CKM0000; RW400: 6121CG40000, 6121CGM0000, 6121CK40000, 6121CK40003, 6121CK40007-G3.0, 6121CK4000D-G3.0, 6121CKM0000; R40: 6122CKP00P0, 6122CKP05P0, 6122CKP06P0; RWK400: 6131CG4020000, 6131CK4000000, 6131CK4000014, 6131CK4000300, 6131CK4020000, 6131CKM000000, 6131CKM000214; RK40: 6132BKP00Q709-G3.0, 6132CKP000009, 6132CKP000011, 6132CKP000700-G3.0, 6132CKP000709-G3.0, 6132CKP001009, 6132CKP001011, 6132CKP00P000, 6132CKP00P009, 6132CKP00P709-G3.0, 6132CKP00Q709-G3.0, 6132CKP030014, 6132CKP060514, 6132CKP06P009, 6132CKP06P609, 6132CKP070209; RW150: 6141CG40000, 6141CGM0000, 6141CK40000, 6141CKM0000;

R15: 6142CKP000Z, 6142CKP00P0, 6142CKP0100; RWKL550: 6171BK4000000, 6171BK4000009, 6171BK4000014, 6171BK4000214, 6171BK4000500, 6171BK4040Z14, 6171BK4060000, 6171BK4060209, 6171BK4060Z09, 6171BK4061000, 6171BKM000000, 6171BKM000200, 6171BKM000300, 6171BKM040400; RWKLB575: 6181BK4000000, 6181BK4000009, 6181BK4000014, 6181BK4000022, 6181BK406C009;

HID Smartid®: 8031DSAP

HID pivClass® R10-H: 900LHRNAK00000, 900LHRTAK00000, 900NHRNAK00000, 900NHRTAK00000, 900PHRNAK00000, 900PHRTAK00000, 910LHRNAK00000, 910LHRTAK00000, 910NHRNAK00000, 910NHRTAK00000, 910PHRNAK00000, 910PHRTAK00000, 920LHRNAK00000, 920LHRTAK00000, 920NHRNAK00000, 920NHRTAK00000, 920PHRNAK00000, 920PHRTAK00000, 921LHRNAK00000, 921LHRTAK00000, 921NHRNAK00000, 921NHRTAK00000, 921PHRNAK00000, 921PHRTAK00000; RPKCL40-P: 923LPRNAK00000, 923LPRTAK00000, 923NPRTAK00000, 923PPRNAK00000, 923PPRTAK00000

AptiqTM: M11, MTK15, MTMSK15, MT15, MTMS15

For information about which compatible RS485 access control readers have been verified by UL, see the Installation Guide available at www.axis.com

Support

Should you require any technical assistance, please contact your Axis reseller. If your questions cannot be answered immediately, your reseller will forward your queries through the appropriate channels to ensure a rapid response. If you are connected to the Internet, you can:

download user documentation and software updates

find answers to resolved problems in the FAQ database. Search by product, category, or phrase

report problems to Axis support staff by logging in to your private support area

chat with Axis support staff (selected countries only)

visit Axis Support at www.axis.com/techsup/

Learn More!

Visit Axis learning center www.axis.com/academy/ for useful trainings, webinars, tutorials and guides.

Image 3
Contents Axis A1001 Network Door Controller & Axis Entry Manager Trademark Acknowledgments About this DocumentLiability Intellectual Property Rights Equipment ModificationsLearn More SupportAxis A1001 Network Door Controller & Axis Entry Manager Front and back Hardware OverviewExternal power inputs Power outputsInterface LED Indicators LED indicators, buttons and other hardwareColor Indication Power Connector Connectors and ButtonsExternal Power Inputs For technical specifications, seeButtons and Other Hardware Power OutputsStart a browser Chrome, Internet Explorer, Firefox, Safari Access from a BrowserAccess from the Internet Set the Root PasswordOverview Select a Language Configuration Step by StepTo import a hardware configuration file Configure the HardwareImport a Hardware Configuration File Export a Hardware Configuration FileMotorized locks must be configured as secondary locks Create a New Hardware ConfigurationConfigure Locks and Door Monitors To create a new hardware configuration from the beginningLock Options Following reader options are available Configure Readers and REX DevicesUse Supervised Inputs Reader and REX Device OptionsVerify the Hardware Connections Set the Date and TimeVerification Controls Configure the Network Settings Set the Date and Time ManuallyGet the Date and Time from the Computer Go to Setup Configure Card Formats Configure Card FormatsBasic TCP/IP Settings To enable card formatsField Maps Card Format DescriptionsConnected Door Controllers List Manage Network Door ControllersDoor Controller System Status Connected Door Controllers in the SystemClick Reset hardware configuration IP address MAC addressRemove Door Controllers from the System Maintenance Instructions Access Management About UsersChoose a Workflow Access Schedule Types Create and Edit Access SchedulesAdd Schedule Items Group Credentials Go to Access Management Groups tab, click Add new groupCreate and Edit Groups Manage DoorsIdentification Types Add Scheduled Unlock StatesClick Add scheduled unlock Manual Door Actions Go to Access ManagementCreate and Edit Users Use Manual Door ActionsFirst name required Last name User CredentialsImport Users Following credentials are available for usersExport Users Example Access Schedule CombinationsCreate a Subtraction schedule called Nights & weekends Event Log Filters View the Alarm LogConfigure the Event and Alarm Logs View the Event LogSet Up Action Rules Alarm Log OptionsEvent Log Options Go to Events Action Rules and click Add Access PointConfiguration TriggersHardware DoorAdd Recipients ActionsFollowing recipients are available Set Up Email RecipientsCreate Schedules Recipient TypesBeeper pattern State Dual LED Single LED Set Up RecurrencesReader Feedback Event WiegandClick Print selected columns View, Print, and Export ReportsReport Types Click View and printIP Address Filter To enable Https on the Axis productSecurity UsersTo allow the product to access a network protected by Ieee IeeeCertificates Create a self-signed certificate as described above Click Install certificate and upload the certificateDate & Time NetworkLinux/Unix example Assign IP Address Using ARP/PingARP/Ping Linux/Unix syntaxNTP Configuration Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service DNS ConfigurationLink-Local IPv4 Address Host Name ConfigurationInformation, see the online help QoS Quality of ServicePorts & Devices MaintenanceLogs & Reports SupportSupport Overview System OverviewFile Upload Reset to Factory Default SettingsAdvanced ScriptingUNIX/Linux, type the following from the command line Upgrade the FirmwareEmergency Recovery Procedure Firmware To upgrade the product’s firmwareProduct is accessible locally but not externally Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserHardware failure Status and Network indicator LEDs are flashing red rapidlyAxis A1001 Network Door Controller Weight Function/group Specifications General CasingPower ConnectorsAxis Entry Manager Connectors Function Pin Reader Data ConnectorReader I/O Connector Function Pin SpecificationsDoor Connector Auxiliary ConnectorPower Connector Tampering Alarm Pin Header Network ConnectorPower Lock Connector Power & Relay ConnectorBack tampering alarm Connection DiagramsSupervised Inputs M5.7
Related manuals
Manual 20 pages 40.35 Kb