Impulse PCW-5181 user manual Index, Faults

Page 117

Index

A

AC power requirements 3-8 acceleration limits 17

accessories for the Impulse - I/O connection 6-7 address of unit 4-24

anti-resonance - enabling 4-17 anti-resonance settings - keypad 5-17 Application Developer

command setup parameters 4-13 file loading options 4-2 installation 4-1

mechanics setup parameters 4-12 motor setup parameters 4-11 non-IDC mechanics 4-12 Project Wizard 4-2

startup menu 4-2

B

Brake output 4-20

C

changing unit number 4-24 configuration text file 4-26 connecting inputs and outputs 3-9 current reduction mode 4-17

D

daisy chaining Impulses 3-5 deceleration limits 17

deleting a file from the keypad 5-10 diagnostic fault indicators 3-8 dimensions of the Impulse 3-11 DIN rail mounting 3-13 downloading files to-from keypad 5-10 drive information 4-26

drive resolution 4-13

Dynamic Smoothing - keypad 5-18

E

Encoderless Stall Detection - keypad 5-19 environmental requirements 3-10

EOT (End of Travel) limit switches 6-6

F

factory authorized distributors 8-1 fault history 4-26

fault indications (LED) 3-8

faults 16

Index

fine-tuning with keypad 5-16 FLASH memory updates 4-27

G

ground connections - motor 3-3 grounding your machine A-1

I

I/O polarity 5-21 IDC web site 8-1 input/output connections 3-9 inputs

EOT (End of Travel) 4-18 Jog - 4-19

Jog + 4-19 Jog Speed 4-19 Kill 4-19 Move Select 4-19 Stop 4-19 Warm Boot 4-19

inputs - keypad 5-20 interlock jumper 3-3

J

jog input/output parameters 4-13

K

keypad

adjusting contrast 5-2 alpha characters 5-5 connecting to Impulse 3-7 downloading files 5-10 menu structure 5-4 motor parameters 5-12 mounting 5-2 operating status 5-9 power-up display 5-5

precision (see Application Note) 5-1 remote mounting 6-2

setting DIP switches 5-2 version numbers 5-9

keypad hardware mounting considerations 6-2

L

low speed tuning 4-15

M

mechanical units 4-12 motor connections 3-3 motor direction 4-13 motor file editor 4-11 motor name 4-11

I-1

Image 117
Contents PCW-5181 Industrial Devices CorporationPage Version Revision HistoryPage Table of Contents END of Manual Impulse Overview Feature FunctionThis page intentionally left blank Shipping Contents This page intentionally left blank Typical Impulse Applications Connecting and Installing Your ImpulseRead This Page Before Your Begin Connecting a Motor to the Impulse Connecting an IDC MotorConnecting a Non-IDC Motor Serial Communication Connections Making RS-232/RS-485 ConnectionsSS-RS232 Multi-Dropping with RS-485 Daisy-Chaining Impulse DrivesRules for Daisy Chain Operation PC/Host RS-232C DeviceJumpers Pin D Troubleshooting RS-232C Communication ProblemsUsing a Keypad with Impulse RS232C Connecting an IDC KeypadUsing a Keypad with Impulse RS485 FP100 KeypadConnecting AC Power LED Diagnostic IndicationsDiagnostic LED Indications LED Signal Application Notes Connecting Inputs and OutputsEnvironmental and Installation Requirements Mounting the Impulse DriveMounting Arrangements Impulse Dimensions Impulse with DIN-rail Mounting Bracket P/N PCS-5111Impulse with Screw-type Mounting Bracket P/N PCS-5110 Installation Installation of Bracket DIN Rail Bracket ShownInserting and Removing Mounting Brackets from the Impulse RemovalMounting the Impulse on the DIN-Rail Impulse DIN-Rail MountingRemoval of Impulse from the DIN-Rail MountingThis page intentionally left blank Installing Application Developer on Windows 95/98/2000/ME/NT Configuring Impulse with Application DeveloperUsing Application Developer Upload Project Open an Existing Project Launch NowUsing the Project Wizard Select Motor Only Configuring Impulse with Application Developer Configuring Impulse with Application Developer Configuring Impulse with Application Developer Fine-Tuning Your Application Axis SetupToolbar Buttons See Appendix C to Edit a Motor MotorMechanics Command Command Signal ConfigurationJog Input Configuration Numeric Precision Adjusting X-Smoothness #1, #2, #3 Smoothness Xtreme SmoothingSmoothness #1 Smoothness #3 Smoothness #2Current Reduction Mode Advanced Advanced TuningAnti-Resonance ProfilingSetup Descriptions Input DescriptionsStall Detection Inactive Output Descriptions Stored Move Setup Editing Stored Moves Configuring Impulse with Application Developer Setup Menu File MenuEdit Menu Communications Menu Run Menu View Menu Updating Your Impulse Operating System This page intentionally left blank Configuring Impulse with an IDC Keypad Keypad FeaturesIntroduction to the FP100 Impulse Keypad Adjusting Contrast Keypad Hardware FeaturesDIP Switch Settings Remote-Mounting the KeypadKeys F1-F2-F3 Functions of the FP100 Keypad KeysRUN Menu Keys KeysMenu Options Keypad Menu StructureFP100 Main Menu and Sub-Menus JOG F3General Rules for Using the Keypad Apply Power to the KeypadRUN Using the RUN Menus File Menu File Options Edit Using the Edit MenusOpening a Project File Saving a Project FileSub-Menu Setup Parameter Description of Setup Parameter Using the Setup Sub-Menus for Configuring Your SystemRenaming an Open Project File Requires Open FileHelp Using the Help Menu Copy Using the Copy Menu DEL Using the DEL Delete menuTo Delete a Project File −−−↑ Motor Type ↓−−− None Parameter Being Configured example Motor TypeUsing the Edit Setup Menus to Configure the Impulse Configuring Impulse with the KeypadConfiguring Motor Type Open a FileConfiguring Motor Direction Configuring Shutdown PolarityTo Probe the Motor Configuring Stop Rate Configuring Drive ResolutionConfiguring Jog Parameters Drive Resolution 25000Configuring Units Gear Ratio Configuring Mechanical Units User UnitsUser Units Units Gear Ratio NumeratorMotor Tuning Setup X-Smoothness ↑ X-Sm1 L1 Value ↓ ↑ X-Sm1 L2 Value ↓ Sm1 Test Speed RPSL2 ← Configuring Anti-Resonance Gain Configuring Stop Mode Current-Reduction Timeout I-STOP Configuring Profiling ParametersConfiguring Encoderless Stall-Detection Olsd Configuring Idle Mode Current Reduction ParametersIdle Mode Tmeout Off Idle Mode %Redct Stall DetectionConfiguring Inputs Setup←↑ Input #1 ↓→ Configuring Outputs Configuring Input/Output Polarities↑ Output #1 ↓ Move Menus Using Stored Moves Stored-Move ProfilesStored Moves Configuring Scan Time Configuring Stored-Move ProfilesMove Selection Input Scan Time Move Sel Scan Time 0 msUnit Number Very Important! Send the File to the DriveHardware Reference Impulse SpecificationsRemote Mounting Your Keypad Extending the Cable Length to Your KeypadEnd View of Wall-Mounted Keypad with Cover Removed Keypad Mounting Template Keypad Mounting *TemplateImpulse I/O Schematics Digital InputsDigital Output Single-Ended Installation Fault OutputDifferential Installation Step, Direction, and Shutdown InputsRPS-1 Accessory P/N & Description SS-RS232PCS-5004 Pin Connector on Impulse Drive DB25BO Screw Terminal Breakout BoardSS-IO/SS-IO-6 Cables S12 Hybrid Step Motor Impulse-Applicable IDC MotorsElectrical Specs S12T Mechanical Specs S12TIDC Motor Wiring S21, S22, S23 Hybrid Step Motor SpecificationsElectrical Specs S21T S21V S22T S22V S23T S23V S22T S22V S23TS32, S33 Hybrid Step Motor Specifications Electrical Specs S32T S33TS32T S33T P21, 22 Hybrid Step Motor Specifications Electrical Specs P21V P22VP21V P22V IDC Motor Wiring 31, 32, 33Step Motor SpecificationsThis page intentionally left blank Troubleshooting the Impulse Troubleshooting TableSymptom Possible Causes Possible Remedies Troubleshooting Your Impulse Limits Tables This page intentionally left blank Product Support Warranty & Repairs Preventing a Ground Loop Appendix a Recommended Wiring Practices for IDC ControlsAppendix a Recommended Wiring Practices Communications Protocol Appendix B Impulse Advanced ProgrammingByte Receive Time Out Reading and Writing Parameter DataReceive Buffer Overrun Read QueriesInterpreting the Transmission Status Response Write Requests01 71 00 00 00 00 72 01 00 00 00 01Serial Jog Velocity RAM Only User Accessible ParametersDescription Determines the acceleration rate value in RPS2 Jog Acceleration Rate28h ParametersFormulas Formula Serial Port Stored Move Selection RAM OnlyCommanded Velocity RAM Only Commanded Position Counter RAM Only Stored Drive Faults Reserved Eeprom ParameterFormulas N/A Index Formulas N/A Index Parameter DescriptionEeprom Enable Switch Description Determines the operational status of the drive System Status RAM OnlyUnit Address DefaultsParameters FormulasParameter Formula Software Shutdown RAM OnlyMotor Wiring Appendix C Using Non-IDC Motors with the ImpulseCustom or User-Defined Motors Test Speeds 1, 2 Smoothness L1 and L2Dynamic Smoothing Anti -Resonance Index FaultsIndex Do Not Print This Inserted as Placeholder Mail info@idcmotion.com Industrial Devices Corporation