American Dryer Corp Phase 7.2.2 user manual Reversing Option, Diagnostics, Program Locations

Page 13

K. REVERSING OPTION

This feature helps reduce balling-up or tangling of large items.

REVERSING OPTION SELECTIONS:

1.Reverse On or Reverse Off

2.This option can be set to “ON” or “OFF” for each cycle individually.

3.Basket (Tumbler) Spin Time and Dwell (Stop) Time

a.Fixed in the Automatic “AUTO” Mode and cannot be changed.

1)Spin Time – 2 minutes forward and 2 minutes reverse.

2)Dwell (Stop) Time – 5-seconds.

b.Programmable in the Manual Mode.

1)Spin Time – Programmable from 30-seconds to 120-seconds, in 1-second increments.

2)Dwell (Stop) Time – Programmable from 5-seconds to 10-seconds, in 1-second increments.

L.DIAGNOSTICS

The Phase 7 non-coin microprocessor controller (computer) monitors the “Drying Functions”, which include temperatures, burners, sail switches, blower, basket (tumbler), and lint drawer.

M. PROGRAM LOCATIONS

System parameters are programmed in Program Locations (PL). Access to this location is acquired by pressing the “STOP/CLEAR” and the “UP ARROW” together. To exit the Programming Location, simply press the “STOP/CLEAR” key. If you are several menu layers deep, continue to press the “STOP/CLEAR” key to back up the menu until you are ALL the way out of the Programming Mode.

0. SELECT LANGUAGE – This menu allows the selection of five (5) different languages to operate the dryer. The language that is selected will be used for every displayed message as well as for faults and menus.

ENGLISH

FRANCAIS

ESPANOL

ITALIANO

DEUTSCH

1.SELECT SYSTEM PARAMETERS – This menu level has four (4) sections. ALL programmable parameters, other than preprogrammed cycles, are done here.

11

Image 13
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Preprogrammed Cycles Program SelectionsPage Automatic Drying Cycle Patent no ,827,627 Operations Manually Loaded CyclesTimed Manual Drying Cycle Operation Temperature Conversion Status Cycle in Progress Temperature DisplayLight Emitting Diode L.E.D. DOT Matrix Display Audio Alert on Times 0 to Wrinkle Guard ProgramPreprogrammed Cycle Preview Reversing Option DiagnosticsProgram Locations Page Preprogrammed Locations for Custom Drying Operating Sequence Operating InstructionsPage Page MAN Operating Notes Fire Suppression System F.S.S. Theory of Operation System ResetFire Suppression System F.S.S. Valve Check Page E.D. Display Operating Status D. Display MessagesIntroduction to Programming Programming InstructionsPage START/ENTER STOP/CLEAR Programming FlowchartsPhase Menu Programming Procedure Page Auto Reverse Mode On OFF 0SELECT Language Selecting LanguagesEnglish EspanolSelecting a Dryer Model Dryer SetupSelect System Parameters Select ModelGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON GAS ReversingSteam NON-REVERSING Electric ReversingSelecting the System Temperature DEG F Enter Lint Cleaning Frequency 1 to 10 HoursDEG C Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location Board Address 00 to ZZ OFFDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out Enter Audio Alert on Times 0 to Rotation Sensor System Temp Enter Lint Cleaning Frequency 1 to 10 HoursAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Enter Spin Time 30 to 120 Seconds Reversing SetupEnter Stop Time 5 to 10 Seconds Press the up arrow key to increment Wrinkle Guard Audio Alert SetupWrinkle Guard Audio Alert Wrinkle Guard SetupSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Cycle Enter 1ST on TimeEnter 1ST OFF Time 511 to 000 First time adjustment is Minutes mmEnter 2ND on Time Program 0-40 Cycles Enter 3RD on TimeProgram System Cycles Parameters Programming a F Cycles or 0 40 CyclesSelect a F KEY Reverse ModeSelect Cycle Type AutoEnter DRY Temp Not AvailableOFF Not Available TimeDRY Enter Dryness LevelEnter Stop Time To 10 Seconds DRY or Extra Extra DRY Enter Cycle AdjustmentEnter DRY Time 0 to 99 Minutes Enter Cool Down Time 0 to 99 Minutes Controlled Cool DownEnter Cool Down Enter Cool Down Temp 70 to 100 ºFSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults YES Defaults SET Default SettingsCycle 0-40 Parameters Programs Preset by the Factory Cycle A-F Parameters Programs Preset by the FactoryPreprogrammed Cycles Fixed Parameters System Parameters Program LocationsGas Standards Diagnostic L.E.D. Display Fault MessagesPage Page Page S.S. Diagnostic Conditions Brhl RED L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08