FLAME FAULT – After the Phase 7 non-coin microprocessor controller (computer) has verified that the gas valve signal was present throughout the Direct Spark Ignition (DSI) purge time and the DSI proof time, the Phase 7 non-coin microprocessor controller (computer) will continue to monitor the gas valve return signal. In the event that the gas valve return signal is lost anytime after the DSI proof time, the Phase 7 non-coin microprocessor controller (computer) will turn off the heat output and increase a counter. Once this fault condition occurs five (5) consecutive times, the Phase 7 non-coin microprocessor controller (computer) will interrupt the cycle, display “Flame Fault” condition, and go into a Fault Mode with a brief audio indication. If the basket (tumbler) temperature is above 100° F (38° C), the Phase 7 non-coin microprocessor controller (computer) will continue to display “Flame Fault”, while the dryer cools by running with no heat for 3 minutes or until the temperature drops below 100° F (38° C). Once the basket (tumbler) temperature is below 100° F (38° C), or the 3 minutes expire, the Phase 7 non-coin microprocessor controller (computer) will shut off ALL outputs and will remain in Fault Mode until the dryer is addressed.

BURNER PURGE FAULT – If the Phase 7 non-coin microprocessor controller (computer) detects the presence of the gas return signal before sending the heat signal out, the Phase 7 non-coin microprocessor controller (computer) will trigger a “Burner Purge Fault” condition and will go into Fault Mode with a brief audio indication. The dryer will run with no heat for 3 minutes or until the temperature drops below 100° F (38° C). Once the basket (tumbler) temperature is below 100° F (38° C), or the 3 minutes expire, the Phase 7 non-coin microprocessor controller (computer) will shut off ALL outputs and will remain in Fault Mode until the dryer is addressed.

BURNER HIGH-LIMIT FAULT – This routine monitors the burner high-limit switch. If the switch opens during the cycle while the heat is on, the dryer will display “Burner High-Limit Fault” and will go into Fault Mode with a brief audio indication. The Phase 7 non-coin microprocessor controller (computer) will check the basket (tumbler) temperature. If the exhaust probe temperature is above 100° F (38° C), the dryer will continue to display “Burner High Limit Fault”, while the dryer cools by running with no heat for 3 minutes or until the temperature drops below 100° F (38° C). Once the exhaust probe temperature is below 100° F (38° C), or the 3 minutes expire, the Phase 7 non-coin microprocessor controller (computer) will shut off ALL outputs and will remain in Fault Mode until the dryer is addressed.

CHECK CONTROL BOARD FUSE #2 – This routine identifies the opening of the main fuse (fuse 2) on the Phase 7 non-coin microprocessor controller (computer) board. If the fuse has opened, the Phase 7 non-coin microprocessor controller (computer) will not allow a cycle to begin and will display a “Check Control Board Fuse #2” condition. If the fuse has opened after the cycle has begun, it will still trigger the check main fuse fault. The dryer will shut off ALL outputs and will go into Fault Mode with a brief audio indication.

CLEAN LINT – This routine monitors the opening of the lint drawer switch and compares the time between openings to the lint cleaning frequency setting. This routine will first prompt the user to clean lint before locking out the dryer. Once the time between cleanings is equal to the Lint Cleaning Frequency setting, the display will prompt the user to clean lint. The lint cleaning frequency limits the amount of time the dryer will run before the Phase 7 non-coin microprocessor controller (computer) locks the dryer out for further use. If the lint drawer is not cleaned within 2 hours of run time, the Phase 7 non-coin microprocessor controller (computer) will be locked out.

EEPROM FAULT ### – Error in memory location. The ### indicates the location of the fault.

80

Image 82
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Program Selections Preprogrammed CyclesPage Automatic Drying Cycle Patent no ,827,627 Operations Manually Loaded CyclesTimed Manual Drying Cycle Operation Temperature Conversion Status Cycle in Progress Temperature DisplayLight Emitting Diode L.E.D. DOT Matrix Display Audio Alert on Times 0 to Wrinkle Guard ProgramPreprogrammed Cycle Preview Reversing Option DiagnosticsProgram Locations Page Preprogrammed Locations for Custom Drying Operating Instructions Operating SequencePage Page MAN Operating Notes System Reset Fire Suppression System F.S.S. Theory of OperationFire Suppression System F.S.S. Valve Check Page D. Display Messages E.D. Display Operating StatusProgramming Instructions Introduction to ProgrammingPage Programming Flowcharts START/ENTER STOP/CLEARPhase Menu Programming Procedure Page Auto Reverse Mode On OFF English Selecting Languages0SELECT Language EspanolSelect System Parameters Dryer SetupSelecting a Dryer Model Select ModelSteam NON-REVERSING GAS ReversingGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON Electric ReversingSelecting the System Temperature DEG F Enter Lint Cleaning Frequency 1 to 10 HoursDEG C Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location OFF Board Address 00 to ZZDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out System Temp Enter Lint Cleaning Frequency 1 to 10 Hours Enter Audio Alert on Times 0 to Rotation SensorAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Enter Spin Time 30 to 120 Seconds Reversing SetupEnter Stop Time 5 to 10 Seconds Press the up arrow key to increment Setup Wrinkle Guard Audio AlertWrinkle Guard Setup Wrinkle Guard Audio AlertSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Enter 1ST on Time Cycle511 to 000 First time adjustment is Minutes mm Enter 1ST OFF TimeEnter 2ND on Time Enter 3RD on Time Program 0-40 CyclesProgramming a F Cycles or 0 40 Cycles Program System Cycles ParametersSelect Cycle Type Reverse ModeSelect a F KEY AutoOFF Not Available Not AvailableEnter DRY Temp TimeDRY Enter Dryness LevelEnter Stop Time To 10 Seconds DRY or Extra Extra DRY Enter Cycle AdjustmentEnter DRY Time 0 to 99 Minutes Controlled Cool Down Enter Cool Down Time 0 to 99 MinutesEnter Cool Down Temp 70 to 100 ºF Enter Cool DownSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults Defaults SET Default Settings YESCycle A-F Parameters Programs Preset by the Factory Cycle 0-40 Parameters Programs Preset by the FactoryPreprogrammed Cycles System Parameters Program Locations Fixed ParametersGas Diagnostic L.E.D. Display Fault Messages StandardsPage Page Page S.S. Diagnostic Conditions INPUT/OUTPUT I/O Board L.E.D. Indicators Brhl RED L.E.DKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08