American Dryer Corp Phase 7.2.2 user manual Preprogrammed Locations for Custom Drying

Page 15

1.REVERSING SETUP – The parameters that pertain to the Reversing Mode are in this menu level.

0.ENTER SPIN TIME 30 TO 120 SECONDS – This parameter (program) is fixed at 2 minutes in the forward direction and 2 minutes in the reverse direction for the Automatic Mode. In the Manual Mode, it is programmable. This Spin Time is programmed here for the Manually Loaded Manual Cycle only.

1.ENTER STOP TIME 5 TO 10 SECONDS – This parameter (program) is fixed at 5-seconds in the Automatic Mode and programmable in the Manual Mode. This Dwell (Stop) Time is programmed here for the Manually Loaded Manual Cycle only.

2.WRINKLE GUARD SETUP – The parameters that pertain to the Wrinkle Guard are in this menu level. 0. WRINKLE GUARD AUDIO ALERT – This parameter (program) allows the operator to turn the

Audio Alert tone on or off at the end of each Wrinkle Guard Cycle.

AUDIO ALERT ON

AUDIO ALERT OFF

3.STEAM INJECTION SETUP (Optional) – This parameter is used to inject steam into the basket (tumbler) up to 5 times. 0-5 ON Time is first entered MM:SS (minutes:seconds), and then the OFF Time is entered MM:SS (minutes:seconds).

2.PROGRAM A-F CYCLES – This menu allows the programming of cycles “A-F”. The parameters selected in this menu for each letter will be stored in memory for that key. This will allow the operator to utilize one-touch drying through keys “A-F”.

3.PROGRAM 0-40 CYCLES – This menu allows the programming of cycles “0-40”. The parameters selected in this menu for each number will be stored in memory for that number key(s). This will allow the operator to utilize preprogrammed drying cycles stored in memory under a numerical location.

NOTE: BOTH THE “A-F” and “0-40” CYCLES ALLOW FOR A TOTAL OF 47

PREPROGRAMMED LOCATIONS FOR CUSTOM DRYING.

4.DEFAULT SETTINGS – This menu allows the operator to set ALL programmable parameters to default settings. This option has a password selection of 1 2 3. It will then ask to confirm settings. It will default to “NO”. Use the arrow keys to select “YES”.

CAUTION: Once the settings have been set to their default settings, there is no way to

retrieve the old settings. Use caution when using this feature.

13

Image 15
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Preprogrammed Cycles Program SelectionsPage Manually Loaded Cycles Automatic Drying Cycle Patent no ,827,627 OperationsTimed Manual Drying Cycle Operation Cycle in Progress Temperature Display Temperature Conversion StatusLight Emitting Diode L.E.D. DOT Matrix Display Wrinkle Guard Program Audio Alert on Times 0 toPreprogrammed Cycle Preview Diagnostics Reversing OptionProgram Locations Page Preprogrammed Locations for Custom Drying Operating Sequence Operating InstructionsPage Page MAN Operating Notes Fire Suppression System F.S.S. Theory of Operation System ResetFire Suppression System F.S.S. Valve Check Page E.D. Display Operating Status D. Display MessagesIntroduction to Programming Programming InstructionsPage START/ENTER STOP/CLEAR Programming FlowchartsPhase Menu Programming Procedure Page Auto Reverse Mode On OFF Espanol Selecting Languages0SELECT Language EnglishSelect Model Dryer SetupSelecting a Dryer Model Select System ParametersElectric Reversing GAS ReversingGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON Steam NON-REVERSINGSelecting the System Temperature Enter Lint Cleaning Frequency 1 to 10 Hours DEG FDEG C Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location Board Address 00 to ZZ OFFDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out Enter Audio Alert on Times 0 to Rotation Sensor System Temp Enter Lint Cleaning Frequency 1 to 10 HoursAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Reversing Setup Enter Spin Time 30 to 120 SecondsEnter Stop Time 5 to 10 Seconds Press the up arrow key to increment Wrinkle Guard Audio Alert SetupWrinkle Guard Audio Alert Wrinkle Guard SetupSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Cycle Enter 1ST on TimeEnter 1ST OFF Time 511 to 000 First time adjustment is Minutes mmEnter 2ND on Time Program 0-40 Cycles Enter 3RD on TimeProgram System Cycles Parameters Programming a F Cycles or 0 40 CyclesAuto Reverse ModeSelect a F KEY Select Cycle TypeTime Not AvailableEnter DRY Temp OFF Not AvailableEnter Dryness Level DRYEnter Stop Time To 10 Seconds Enter Cycle Adjustment DRY or Extra Extra DRYEnter DRY Time 0 to 99 Minutes Enter Cool Down Time 0 to 99 Minutes Controlled Cool DownEnter Cool Down Enter Cool Down Temp 70 to 100 ºFSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults YES Defaults SET Default SettingsCycle 0-40 Parameters Programs Preset by the Factory Cycle A-F Parameters Programs Preset by the FactoryPreprogrammed Cycles Fixed Parameters System Parameters Program LocationsGas Standards Diagnostic L.E.D. Display Fault MessagesPage Page Page S.S. Diagnostic Conditions Brhl RED L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08