American Dryer Corp Phase 7.2.2 user manual Light Emitting Diode L.E.D. DOT Matrix Display

Page 11

E. LIGHT EMITTING DIODE (L.E.D.) DOT MATRIX DISPLAY

The L.E.D. display informs the user of cycle status, program verification, and displays important diagnostic and fault information. A complete listing of the various display messages and their meanings is shown in Section V of this manual.

CYCLE IN PROGRESS DISPLAY STATUS

During the Drying Cycle, the display will indicate the type of cycle in progress by presenting either one (1) of the following:

1.“AUTO DRYING CYCLE” – Manually Loaded Auto Cycle.

2.“AUTO DRYING CYCLE #” – The “#” is replaced with “A-F” or “0-40”.

3.“MANUAL DRYING CYCLE” – Manually Loaded Manual Cycle.

4.“MANUAL DRYING CYCLE #” – The “#” is replaced with “A-F” or “0-40”.

F.CYCLE IN PROGRESS TEMPERATURE DISPLAY

While the dryer cycle is in progress, the temperature in the basket (tumbler) can be displayed by pressing and holding the “UP ARROW” key. The temperature will be displayed in either Fahrenheit (°F) or Celsius (°C), depending on which temperature system has been set in the “DRYER SETUP”.

G. TEMPERATURE CONVERSION STATUS

Temperature related programs are programmable to be operated in either Fahrenheit (°F) or Celsius (°C). The temperature selection is made in “SYSTEM TEMP”. The programs affected are as follows:

1.Temperature Display Mode

2.Drying Temperatures

3.Cool Down Temperatures

IMPORTANT: When changing the temperature conversion status from Fahrenheit to Celsius, or vice versa, ALL of the Temperature Selections and Cool Down Temperatures will be changed accordingly. The Phase 7 non-coin microprocessor controller (computer) automatically calculates and converts the temperatures in these programs to the previously set value. For example, if the preprogrammed Cycle “A” drying temperature was set for 160° F, when converting from °F to °C, the Phase 7 non-coin microprocessor controller (computer) will change to 71° C (+/- 1° Celsius).

9

Image 11
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Preprogrammed Cycles Program SelectionsPage Timed Manual Drying Cycle Operation Manually Loaded CyclesAutomatic Drying Cycle Patent no ,827,627 Operations Light Emitting Diode L.E.D. DOT Matrix Display Cycle in Progress Temperature DisplayTemperature Conversion Status Preprogrammed Cycle Preview Wrinkle Guard ProgramAudio Alert on Times 0 to Program Locations DiagnosticsReversing Option Page Preprogrammed Locations for Custom Drying Operating Sequence Operating InstructionsPage Page MAN Operating Notes Fire Suppression System F.S.S. Theory of Operation System ResetFire Suppression System F.S.S. Valve Check Page E.D. Display Operating Status D. Display MessagesIntroduction to Programming Programming InstructionsPage START/ENTER STOP/CLEAR Programming FlowchartsPhase Menu Programming Procedure Page Auto Reverse Mode On OFF Espanol Selecting Languages0SELECT Language EnglishSelect Model Dryer SetupSelecting a Dryer Model Select System ParametersElectric Reversing GAS ReversingGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON Steam NON-REVERSINGSelecting the System Temperature DEG C Enter Lint Cleaning Frequency 1 to 10 HoursDEG F Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location Board Address 00 to ZZ OFFDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out Enter Audio Alert on Times 0 to Rotation Sensor System Temp Enter Lint Cleaning Frequency 1 to 10 HoursAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Enter Stop Time 5 to 10 Seconds Reversing SetupEnter Spin Time 30 to 120 Seconds Press the up arrow key to increment Wrinkle Guard Audio Alert SetupWrinkle Guard Audio Alert Wrinkle Guard SetupSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Cycle Enter 1ST on TimeEnter 1ST OFF Time 511 to 000 First time adjustment is Minutes mmEnter 2ND on Time Program 0-40 Cycles Enter 3RD on TimeProgram System Cycles Parameters Programming a F Cycles or 0 40 CyclesAuto Reverse ModeSelect a F KEY Select Cycle TypeTime Not AvailableEnter DRY Temp OFF Not AvailableEnter Stop Time To 10 Seconds Enter Dryness LevelDRY Enter DRY Time 0 to 99 Minutes Enter Cycle AdjustmentDRY or Extra Extra DRY Enter Cool Down Time 0 to 99 Minutes Controlled Cool DownEnter Cool Down Enter Cool Down Temp 70 to 100 ºFSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults YES Defaults SET Default SettingsCycle 0-40 Parameters Programs Preset by the Factory Cycle A-F Parameters Programs Preset by the FactoryPreprogrammed Cycles Fixed Parameters System Parameters Program LocationsGas Standards Diagnostic L.E.D. Display Fault MessagesPage Page Page S.S. Diagnostic Conditions Brhl RED L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08