EXHAUST HIGH-LIMIT FAULT – This routine monitors the basket (tumbler) safety over temperature switch. If the switch opens, the dryer will display “Exhaust High-Limit Fault” and will go into Fault Mode with a brief audio indication. If the basket (tumbler) temperature is above 100° F (38° C) the dryer will continue to display “Exhaust High-Limit Fault”, while the Phase 7 non-coin microprocessor controller (computer) cools by running with no heat for 3 minutes or until the temperature drops below 100° F (38° C). Once the basket (tumbler) temperature is below 100° F (38° C), or the 3 minutes expire, the Phase 7 non-coin microprocessor controller (computer) will shut off ALL outputs and will remain in Fault Mode until the dryer is addressed.

EXHAUST PROBE FAULT/AXIAL PROBE FAULT – This routine indicates a problem with the temperature sensor circuit. This error will trigger an “Exhaust Probe Fault or Axial Probe Fault” condition and will go into a Fault Mode with a brief audio indication. The dryer will run with no heat for 3 minutes. Once the 3 minutes expire, the Phase 7 non-coin microprocessor controller (computer) will shut off ALL outputs and will remain in Fault Mode until the dryer is addressed.

EXHAUST HIGH TEMP FAULT – This error routine indicates a problem with overheating. This error will initiate an “Exhaust High Temp Fault” condition and will go into Fault Mode with a brief audio indication. The Phase 7 non-coin microprocessor controller (computer) determines this error by monitoring the temperature sensor input to have a steady gradual increase in temperature to a known upper limit (the limit typically is 20° over the maximum allowed programmable set point). The dryer will run with no heat for 3 minutes or until the temperature drops below 100° F (38° C). Once the basket (tumbler) temperature is below 100° F (38° C), or 3 minutes expire, the Phase 7 non-coin microprocessor controller (computer) will shut off ALL outputs and remain in Fault Mode until the dryer is addressed.

LINT ACCESS OPEN – Indicates the lint drawer is open and needs to be closed.

LOW VOLTAGE FAULT – Indicates power has dropped below the operating values and will shutdown.

MAIN DOOR OPENED – Indicates the main door is open when it should be closed.

MODEL ERROR, ENTER CORRECT MODEL – This routine monitors the inputs, such as the sail switch and gas valve. Steam dryers DO NOT use a sail switch or valve input, and an electric dryer will not use a gas valve input. These signals allow the Phase 7 non-coin microprocessor controller (computer) to interpret what type of dryer it is controlling. The Phase 7 non-coin microprocessor controller (computer) determines what the expected dryer responses should be for that specific heat type dryer. Anytime a model fault is detected, the Phase 7 non-coin microprocessor controller (computer) will interrupt the cycle and will display “MODEL ERROR, ENTER CORRECT MODEL–” and go into Fault Mode with a brief audio indication. If the basket (tumbler) temperature is above 100° F (38° C) at the time of the failure, the Phase 7 non-coin microprocessor controller (computer) will continue to display “MODEL ERROR, ENTER CORRECT MODEL–” while the dryer cools by running with no heat for 3 minutes or until the temperature drops below 100° F (38° C). Once the basket (tumbler) temperature is below 100° F (38° C), or the 3 minutes expire, the Phase 7 non-coin microprocessor controller (computer) will shut off ALL outputs and will remain in Fault Mode until the dryer is addressed.

NOTE: If a model error occurs, the Phase 7 non-coin microprocessor controller (computer) will always default to the “gas” type for safety reasons. Also, the dryer will be stopped and forced into a restart condition to reevaluate ALL the expected responses.

81

Image 83
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Preprogrammed Cycles Program SelectionsPage Timed Manual Drying Cycle Operation Manually Loaded CyclesAutomatic Drying Cycle Patent no ,827,627 Operations Light Emitting Diode L.E.D. DOT Matrix Display Cycle in Progress Temperature DisplayTemperature Conversion Status Preprogrammed Cycle Preview Wrinkle Guard ProgramAudio Alert on Times 0 to Program Locations DiagnosticsReversing Option Page Preprogrammed Locations for Custom Drying Operating Sequence Operating InstructionsPage Page MAN Operating Notes Fire Suppression System F.S.S. Theory of Operation System ResetFire Suppression System F.S.S. Valve Check Page E.D. Display Operating Status D. Display MessagesIntroduction to Programming Programming InstructionsPage START/ENTER STOP/CLEAR Programming FlowchartsPhase Menu Programming Procedure Page Auto Reverse Mode On OFF Espanol Selecting Languages0SELECT Language EnglishSelect Model Dryer SetupSelecting a Dryer Model Select System ParametersElectric Reversing GAS ReversingGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON Steam NON-REVERSINGSelecting the System Temperature DEG C Enter Lint Cleaning Frequency 1 to 10 HoursDEG F Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location Board Address 00 to ZZ OFFDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out Enter Audio Alert on Times 0 to Rotation Sensor System Temp Enter Lint Cleaning Frequency 1 to 10 HoursAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Enter Stop Time 5 to 10 Seconds Reversing SetupEnter Spin Time 30 to 120 Seconds Press the up arrow key to increment Wrinkle Guard Audio Alert SetupWrinkle Guard Audio Alert Wrinkle Guard SetupSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Cycle Enter 1ST on TimeEnter 1ST OFF Time 511 to 000 First time adjustment is Minutes mmEnter 2ND on Time Program 0-40 Cycles Enter 3RD on TimeProgram System Cycles Parameters Programming a F Cycles or 0 40 CyclesAuto Reverse ModeSelect a F KEY Select Cycle TypeTime Not AvailableEnter DRY Temp OFF Not AvailableEnter Stop Time To 10 Seconds Enter Dryness LevelDRY Enter DRY Time 0 to 99 Minutes Enter Cycle AdjustmentDRY or Extra Extra DRY Enter Cool Down Time 0 to 99 Minutes Controlled Cool DownEnter Cool Down Enter Cool Down Temp 70 to 100 ºFSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults YES Defaults SET Default SettingsCycle 0-40 Parameters Programs Preset by the Factory Cycle A-F Parameters Programs Preset by the FactoryPreprogrammed Cycles Fixed Parameters System Parameters Program LocationsGas Standards Diagnostic L.E.D. Display Fault MessagesPage Page Page S.S. Diagnostic Conditions Brhl RED L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08