American Dryer Corp Phase 7.2.2 user manual Section

Page 5

SECTION I

INTRODUCTION

Phase 7 Non-Coin Microprocessor Controller (Computer) Drying System

The Phase 7 Non-Coin Microprocessor Controller (Computer) Drying System has been designed with super performance in mind to provide for better temperature regulation, efficiency, performance, consistency, and faster drying times.

Among its many amenities, the Phase 7 Non-Coin Microprocessor Controller (Computer) Drying System has a true Automatic Drying Cycle. The Phase 7 Non-Coin Automatic Drying Cycle (Patent No. 4,827,627) principle is based on one (1) of the most fundamental laws of thermodynamics, which governs the flow of heat in thermal systems.

Utilizing this Phase 7 non-coin microprocessor controller (computer) technology, the user simply has to place the load in the dryer and push one (1) single button to start the drying cycle. The Phase 7 non-coin microprocessor controller (computer) will directly monitor the moisture content in the load and stop the drying cycle automatically when the selected dryness level is reached.

The Phase 7 Non-Coin Automatic Drying Cycle (Patent No. 4,827,627) virtually eliminates ALL guesswork. The Phase 7 non-coin microprocessor controller (computer) determines how much drying time is needed and compensates for various types of fabrics and load sizes, therefore, avoiding damage to fabrics by overdrying, as well as avoiding wasted time and energy for any given load. Once the Phase 7 non-coin microprocessor controller (computer) determines that the load is dry, the Phase 7 non-coin microprocessor controller (computer) will go into the Cool Down Cycle until the preprogrammed time or temperature is reached, and then will shut the dryer off automatically.

3

Image 5
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Preprogrammed Cycles Program SelectionsPage Timed Manual Drying Cycle Operation Manually Loaded CyclesAutomatic Drying Cycle Patent no ,827,627 Operations Light Emitting Diode L.E.D. DOT Matrix Display Cycle in Progress Temperature DisplayTemperature Conversion Status Preprogrammed Cycle Preview Wrinkle Guard ProgramAudio Alert on Times 0 to Program Locations DiagnosticsReversing Option Page Preprogrammed Locations for Custom Drying Operating Sequence Operating InstructionsPage Page MAN Operating Notes Fire Suppression System F.S.S. Theory of Operation System ResetFire Suppression System F.S.S. Valve Check Page E.D. Display Operating Status D. Display MessagesIntroduction to Programming Programming InstructionsPage START/ENTER STOP/CLEAR Programming FlowchartsPhase Menu Programming Procedure Page Auto Reverse Mode On OFF 0SELECT Language Selecting LanguagesEnglish EspanolSelecting a Dryer Model Dryer SetupSelect System Parameters Select ModelGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON GAS ReversingSteam NON-REVERSING Electric ReversingSelecting the System Temperature DEG C Enter Lint Cleaning Frequency 1 to 10 HoursDEG F Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location Board Address 00 to ZZ OFFDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out Enter Audio Alert on Times 0 to Rotation Sensor System Temp Enter Lint Cleaning Frequency 1 to 10 HoursAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Enter Stop Time 5 to 10 Seconds Reversing SetupEnter Spin Time 30 to 120 Seconds Press the up arrow key to increment Wrinkle Guard Audio Alert SetupWrinkle Guard Audio Alert Wrinkle Guard SetupSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Cycle Enter 1ST on TimeEnter 1ST OFF Time 511 to 000 First time adjustment is Minutes mmEnter 2ND on Time Program 0-40 Cycles Enter 3RD on TimeProgram System Cycles Parameters Programming a F Cycles or 0 40 CyclesSelect a F KEY Reverse ModeSelect Cycle Type AutoEnter DRY Temp Not AvailableOFF Not Available TimeEnter Stop Time To 10 Seconds Enter Dryness LevelDRY Enter DRY Time 0 to 99 Minutes Enter Cycle AdjustmentDRY or Extra Extra DRY Enter Cool Down Time 0 to 99 Minutes Controlled Cool DownEnter Cool Down Enter Cool Down Temp 70 to 100 ºFSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults YES Defaults SET Default SettingsCycle 0-40 Parameters Programs Preset by the Factory Cycle A-F Parameters Programs Preset by the FactoryPreprogrammed Cycles Fixed Parameters System Parameters Program LocationsGas Standards Diagnostic L.E.D. Display Fault MessagesPage Page Page S.S. Diagnostic Conditions Brhl RED L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08