American Dryer Corp Phase 7.2.2 user manual Gas

Page 80

SECTION IX

PHASE 7 NON-COIN AUTO CYCLE (PATENT NO. 4,827,627)

CYCLEADJUSTMENT VALUES

Gas

Adjustment

Model

Value

MLG-55

65

 

 

MLG-758

60

 

 

MLG-75V

70

 

 

MLG-78

70

 

 

MLG-82

62

 

 

MLG-96

70

 

 

MLG-122

70

 

 

MLG-130

73

 

 

MLG-170

68

 

 

Electric

Adjustment

Model

Value

MLE-120ES

78

 

 

MLE-170SE

70

 

 

Steam

Adjustment

Model

Value

MLS-130

65

 

 

MLS-170

70

 

 

IMPORTANT: If your particular model/dryer dryness levels are not shown in the above charts, contact the Service Department for the appropriate factors for your particular dryer. When doing so, please have the dryer model and serial numbers available.

IMPORTANT: The adjustment values have been preprogrammed by the factory, but can be changed in the field. IF THE PHASE 7 NON-COIN MICROPROCESSOR

CONTROLLER (COMPUTER) SHOULD FAILAND IS BEING REPLACED, THE REPLACEMENT PHASE 7 NON-COIN MICROPROCESSOR CONTROLLER (COMPUTER) MUST BE REPROGRAMMED FOR THE SPECIFIC MODEL SHOWN IN THE ADJUSTMENT VALUE PARAMETERS CHARTS ABOVE. THE ADJUSTMENT VALUE LABEL IS LOCATED ON THE TOP CONTROL PANEL, BEHIND THE KEYBOARD (TOUCH PAD) DISPLAY DOOR.

NOTE: When fine-tuning theAuto Cycle for certain loads, if the clothes comes out wet decrease the adjustment value; if the material comes out too dry, increase the adjustment value.

78

Image 80
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Program Selections Preprogrammed CyclesPage Timed Manual Drying Cycle Operation Manually Loaded CyclesAutomatic Drying Cycle Patent no ,827,627 Operations Light Emitting Diode L.E.D. DOT Matrix Display Cycle in Progress Temperature DisplayTemperature Conversion Status Preprogrammed Cycle Preview Wrinkle Guard ProgramAudio Alert on Times 0 to Program Locations DiagnosticsReversing Option Page Preprogrammed Locations for Custom Drying Operating Instructions Operating SequencePage Page MAN Operating Notes System Reset Fire Suppression System F.S.S. Theory of OperationFire Suppression System F.S.S. Valve Check Page D. Display Messages E.D. Display Operating StatusProgramming Instructions Introduction to ProgrammingPage Programming Flowcharts START/ENTER STOP/CLEARPhase Menu Programming Procedure Page Auto Reverse Mode On OFF Selecting Languages 0SELECT LanguageEnglish EspanolDryer Setup Selecting a Dryer ModelSelect System Parameters Select ModelGAS Reversing GAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NONSteam NON-REVERSING Electric ReversingSelecting the System Temperature DEG C Enter Lint Cleaning Frequency 1 to 10 HoursDEG F Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location OFF Board Address 00 to ZZDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out System Temp Enter Lint Cleaning Frequency 1 to 10 Hours Enter Audio Alert on Times 0 to Rotation SensorAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Enter Stop Time 5 to 10 Seconds Reversing SetupEnter Spin Time 30 to 120 Seconds Press the up arrow key to increment Setup Wrinkle Guard Audio AlertWrinkle Guard Setup Wrinkle Guard Audio AlertSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Enter 1ST on Time Cycle511 to 000 First time adjustment is Minutes mm Enter 1ST OFF TimeEnter 2ND on Time Enter 3RD on Time Program 0-40 CyclesProgramming a F Cycles or 0 40 Cycles Program System Cycles ParametersReverse Mode Select a F KEYSelect Cycle Type AutoNot Available Enter DRY TempOFF Not Available TimeEnter Stop Time To 10 Seconds Enter Dryness LevelDRY Enter DRY Time 0 to 99 Minutes Enter Cycle AdjustmentDRY or Extra Extra DRY Controlled Cool Down Enter Cool Down Time 0 to 99 MinutesEnter Cool Down Temp 70 to 100 ºF Enter Cool DownSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults Defaults SET Default Settings YES Cycle A-F Parameters Programs Preset by the Factory Cycle 0-40 Parameters Programs Preset by the FactoryPreprogrammed Cycles System Parameters Program Locations Fixed ParametersGas Diagnostic L.E.D. Display Fault Messages StandardsPage Page Page S.S. Diagnostic Conditions INPUT/OUTPUT I/O Board L.E.D. Indicators Brhl RED L.E.DKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08