American Dryer Corp Phase 7.2.2 user manual Man

Page 19

NOTE: Press and hold the “DOWN ARROW” to view the basket (tumbler) RPM.

7)Once the preprogrammed percentage of extraction (dryness level) is reached, the drying cycle will end and the Cool Down Cycle will begin.

8)Once the Cool Down Cycle begins at the end of the heat cycle, the light emitting diode (L.E.D.) display will read COOL DOWN TEMP ___/___MINUTES REMAINING. At the end of the heat cycle, the dryer will shut off the heat and continue the fan and basket (tumbler) until the Cool Down Time or temperature is reached.

9)Once the Cool Down Cycle is completed, the Phase 7 non-coin microprocessor controller (computer) will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound (for the amount set in Audio Alert On Time). The L.E.D. display will read “CYCLE DONE”. The dryer will wait an initial 15 minutes delay before going into a 15-seconds ON, 5 minutes OFF cycle. These times are fixed and are not programmable. During the ON Time, the blower (fan) and the basket (tumbler) will start to rotate without heat for 15-seconds; during this time the display will read “WRINKLE GUARD”. After the 15-seconds are completed, the display will read “CYCLE DONE” and the dryer will go into a 5 minute OFF cycle. The Phase 7 non-coin microprocessor controller (computer) will repeat this process of 15-seconds “ON” and 5 minutes “OFF” until either the doors are opened,

the “STOP/CLEAR” key is pressed, or 99 minutes have elapsed, whichever comes first. Once the 99 minutes have elapsed, the L.E.D. display will then read “CYCLE DONE” and will lock out the dryer functions until the doors are opened. The L.E.D. display will then return to “READY”.

b. Timed (Manual) Drying Cycle

1)L.E.D. display reads “READY” (no cycle in progress).

2) Press

MAN

key.

3)L.E.D. display will now read “ENTER DRY TIME 0 TO 99 MINUTES” (defaults to 0). I.E., for

40 minutes, press key “4”, key “0”, and then press the “START/ENTER” key to accept the value.

4)L.E.D. display will now read “ENTER DRY TEMP __ TO __” (defaults to 100° F [38° C]). Enter the temperature desired (from 100° F to 200° F [38° C to 93° C] in one-degree increments). I.E.,

for 182° F (83° C), press key “1”, key “8”, key “2”, and then press the “START/ENTER” key to accept the value.

5)L.E.D. display will now read “ENTER COOL DOWN TIME 0 TO 99 MINUTES”. I.E., for 10 minutes, press key “1”, key “0”, and then press the “START/ENTER” key to accept the value.

6)L.E.D. display will now read “REVERSE MODE” (defaults to ON). The ON/OFF selection can

be toggled with the “UP ARROW” and “DOWN ARROW” . Once selected, press the “START/ENTER” key to accept selection.

17

Image 19
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Preprogrammed Cycles Program SelectionsPage Automatic Drying Cycle Patent no ,827,627 Operations Manually Loaded CyclesTimed Manual Drying Cycle Operation Temperature Conversion Status Cycle in Progress Temperature DisplayLight Emitting Diode L.E.D. DOT Matrix Display Audio Alert on Times 0 to Wrinkle Guard ProgramPreprogrammed Cycle Preview Reversing Option DiagnosticsProgram Locations Page Preprogrammed Locations for Custom Drying Operating Sequence Operating InstructionsPage Page MAN Operating Notes Fire Suppression System F.S.S. Theory of Operation System ResetFire Suppression System F.S.S. Valve Check Page E.D. Display Operating Status D. Display MessagesIntroduction to Programming Programming InstructionsPage START/ENTER STOP/CLEAR Programming FlowchartsPhase Menu Programming Procedure Page Auto Reverse Mode On OFF Espanol Selecting Languages0SELECT Language EnglishSelect Model Dryer SetupSelecting a Dryer Model Select System ParametersElectric Reversing GAS ReversingGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON Steam NON-REVERSINGSelecting the System Temperature DEG F Enter Lint Cleaning Frequency 1 to 10 HoursDEG C Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location Board Address 00 to ZZ OFFDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out Enter Audio Alert on Times 0 to Rotation Sensor System Temp Enter Lint Cleaning Frequency 1 to 10 HoursAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Enter Spin Time 30 to 120 Seconds Reversing SetupEnter Stop Time 5 to 10 Seconds Press the up arrow key to increment Wrinkle Guard Audio Alert SetupWrinkle Guard Audio Alert Wrinkle Guard SetupSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Cycle Enter 1ST on TimeEnter 1ST OFF Time 511 to 000 First time adjustment is Minutes mmEnter 2ND on Time Program 0-40 Cycles Enter 3RD on TimeProgram System Cycles Parameters Programming a F Cycles or 0 40 CyclesAuto Reverse ModeSelect a F KEY Select Cycle TypeTime Not AvailableEnter DRY Temp OFF Not AvailableDRY Enter Dryness LevelEnter Stop Time To 10 Seconds DRY or Extra Extra DRY Enter Cycle AdjustmentEnter DRY Time 0 to 99 Minutes Enter Cool Down Time 0 to 99 Minutes Controlled Cool DownEnter Cool Down Enter Cool Down Temp 70 to 100 ºFSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults YES Defaults SET Default SettingsCycle 0-40 Parameters Programs Preset by the Factory Cycle A-F Parameters Programs Preset by the FactoryPreprogrammed Cycles Fixed Parameters System Parameters Program LocationsGas Standards Diagnostic L.E.D. Display Fault MessagesPage Page Page S.S. Diagnostic Conditions Brhl RED L.E.D INPUT/OUTPUT I/O Board L.E.D. IndicatorsKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08