817

Output value indica-

When the light source

0~1023

Displays the output value of image

2

 

tion of image quality

is OFF

 

 

quality sensor when the sensor light

 

 

sensor

 

 

 

source is OFF.

 

 

 

 

 

 

 

 

818

 

Transfer belt surface

0~1023

Displays the output value of image

2

 

 

 

 

 

quality sensor when there is no test

 

 

 

 

 

 

pattern on the transfer belt.

 

 

 

 

 

 

 

 

819

 

Low density pattern

0~1023

Displays the output value of image

10

 

 

 

 

 

quality sensor when a low-density

 

 

 

 

 

 

test pattern is written.

 

 

 

 

 

 

 

 

820

 

High density pattern

0~1023

Displays the output value of image

10

 

 

 

 

 

quality sensor when a high-density

 

 

 

 

 

 

test pattern is written.

 

 

 

 

 

 

 

 

821

Light amount adjustment results of image qual-

0~255

The sensor's LED light amount ad-

2

 

ity sensor

 

 

 

justment value, for setting the re-

 

 

 

 

 

 

flected light amount from the belt

 

 

 

 

 

 

surface as the reference value.

 

 

 

 

 

 

 

 

878

Forced performing of image quality control

Perform the image quality control

6

 

 

 

 

 

 

 

879

Automatic initialization of image quality control

Perform the image quality control

6

 

 

 

 

 

and restore the initial value.

 