E43

ADU unit pulled out during copying

Is the ADU unit mounted securely on the copier?

NO

YES

Mount the ADU unit securely to the copier.

Is connector J103 on the LGC board disconnected?

Is the harness between the LGC board and the ADU drawer connector open-circuited?

YES

Reconnect the connector. Replace the harness.

 

NO

1. Replace the LGC board.

2. Replace the ADU unit.

E45

LCF jam access cover opened during copying

Is the LCF jam access cover open?

YES

Close the LCF jam access cover.

 

NO

Is the harness between the LGC board and the LCF unit open-circuited?

Is the relay connector of the harness between the LGC board and the LCF unit or the connector J105 on the LGC board disconnected?

YES

NO

Reconnect the connector. Replace the harness.

1.Replace the LGC board.

2.Replace the LCF unit.

January 2000 © TOSHIBA TEC

4 - 7

FC-22 TROUBLESHOOTING

Page 133
Image 133
Toshiba FC-22 manual E43 ADU unit pulled out during copying, Is the ADU unit mounted securely on the copier?