Allowable

 

 

 

Operation

Code

Name

Default

 

Contents

procedure

input value

 

 

 

 

 

 

 

group

 

 

 

 

 

 

 

407

Image quality control auto-start

0

0-1

When operating continuous printing, image

1

 

(continuous print)

 

 

quality control is started for every print vol-

 

 

 

 

 

ume set for continuos print (08-453).

 

 

 

 

 

0: Disabled

 

 

 

 

 

 

 

1: Enabled (Set value of 08-453)

 

 

 

 

 

 

 

408

Image quality control auto-start

1

0-1

When the accumulated print volume since

1

 

(accumulated print volume)

 

 

the last image quality control, set in 08-

 

 

 

 

 

455, is attained, new image quality control

 

 

 

 

 

automatically starts after the current print-

 

 

 

 

 

ing job.

 

 

 

 

 

 

 

0: Disabled

 

 

 

 

 

 

 

1: Enabled (Setting value of 08-455)

 

 

 

 

 

 

 

409

Image quality control 3

1

0-1

Auto-performing of image quality control

1

 

 

 

 

0: Disabled

 

 

 

 

 

 

 

1: Enabled (Performing 08-410,413)

 

 

 

 

 

 

 

410

Drum temperature compensation

1

0-1

Performing drum temperature compensa-

1

 

control

 

 

tion for image quality control.

 

 

 

 

 

0: Disabled

1: Enabled

 

 

 

 

 

 

* When ‘Image quality controls 1 and 3 (08-

 

 

 

 

 

400,409)’ are 1(Enabled), this is reflected.

 

 

 

 

 

 

 

413

Transfer bias temperature and

1

0-1

Performing transfer bias correction by tem-

1

 

humidity correction control

 

 

perature and humidity for image quality

 

 

 

 

 

control.

 

 

 

 

 

 

 

0: Disabled

1: Enabled

 

 

 

 

 

 

* When ‘Image quality controls 1 and 3 (08-

 

 

 

 

 

400,409)’ are 1(Enabled), this is reflected.

 

 

 

 

 

 

 

415

Abnormal detection counter Y

0

0-16

Accumulated total of CE1, CE2, CE4

1

 

(display/0 clearing)

 

 

(Max.16)

 

 

 

 

 

 

 

* Enabled when ‘Image quality control 3

 

 

 

 

 

(08-401)’ is 1(Enabled).

 

 

 

 

 

 

 

 

 

416

Abnormal detection counter M

0

0-16

Accumulated total of

CE1, CE2, CE4

1

 

(display/0 clearing)

 

 

(Max.16)

 

 

 

 

 

 

 

* Enabled when ‘Image quality control 3

 

 

 

 

 

(08-401)’ is 1 (Enabled).

 

 

 

 

 

 

 

 

 

417

Abnormal detection counter C

0

0-16

Accumulated total of

CE1, CE2, CE4

1

 

(display/0 clearing)

 

 

(Max.16)

 

 

 

 

 

 

 

* Enabled when ‘Image quality control 3

 

 

 

 

 

(08-401)’ is 1 (Enabled).

 

 

 

 

 

 

 

 

 

 

January 2000 © TOSHIBA TEC

1 - 35

FC-22 ADJUSTMENT

Page 50
Image 50
Toshiba FC-22 manual Image quality control auto-start