5.Check if the distance C is within a range of 5±0.5 mm or not.

6.If it is not, change values using the following procedure, and repeat the steps 3. to 5. above.

<Procedure>

(Adjustment mode) n (Input code [106] with digital keys) n [START] n (Input a value

 

(acceptable values : 5 to 251) with digital keys) n [INTERRUPT] (Stored in memory)

*The larger the adjustment value, the shorter the distance C becomes (0.042 mm/ step).

7.When the distance C is within the acceptable range, perform the following procedure.

<Procedure>

(Adjustment mode) n (Input code [108] with digital keys) n [START] n (Input a setting

 

value with digital keys, deducting 47 from the value set in the code [106] adjustment

 

mode 05) n [INTERRUPT] (Stored in memory)

(f) Secondary-scanning data write start position adjustment (Copier)

1.While pressing the digital keys [0] and [5] simultaneously, turn the power ON. n (Adjustment mode)

2.Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).

3.Press [ENERGY SAVER] n [START] to make a copy in the mode of A4 (LT), 100%, full color and text/ photo.

4.Measure the distance D from the upper paper edge to the upper write-start position on the copy with a ruler.

5.Check if the distance D is within a range of 5±0.5 mm or not.

6.If it is not, change values using the following procedure, and repeat the steps 3. to 5. above.

*This adjustment should be done for each of the cassettes.

The adjustment order is : 2nd cassette n 1st cassette n 3rd cassette n 4th cassette n Bypass

tray n LCF n ADU.

 

 

 

 

 

 

The adjustment code for each cassette is as follows:

 

 

 

1st cassette

: 484

2nd cassette

: 485

3rd cassette

:

486

4th cassette

: 487

Bypass tray

: 488

LCF

:

489

ADU

: 490

 

 

 

 

 

<Procedure>

(Adjustment mode) n (Input a code [485 to 490] with digital keys) n [START] n (Input

 

a value (acceptable values : 0 to 15) with digital keys) n [INTERRUPT] (Stored in

 

memory)

*The larger the adjustment value, the longer the distance D becomes (0.6 mm/step).

(g)Scanner (secondary scanning) start position deviation

1.While pressing the digital keys [0] and [5] simultaneously, turn the power ON. n (Adjustment mode)

2.Place Test Chart No. TCC-1 on the original glass (with the arrow positioned at the left rear side).