Toshiba FC-22 Guide bar swing motor rotation abnormal, Stapler-unit swing motor rotation abnormal

Models: FC-22

1 238
Download 238 pages 20.74 Kb
Page 168
Image 168

CC4

Guide bar swing motor rotation abnormal

At the time the guide bar swings, does pulse output occur on J13-3 to J13-6 on the sorter controller board? In addition, does the voltage between J13-1 and J13-2 show 24V?

YES

Check the wiring up to the guide bar swing motor (M3). If it is normal, replace the

 

guide bar swing motor.

NO

Is a voltage of 24V being supplied from the copier?

YES

Replace the sorter controller board.

NO

Check the 24V-power supply of the copier.

CC5

Stapler-unit swing motor rotation abnormal

At the time the stapler unit swings, does the voltage between J9-1 (+) and J9-2 (–) on the sorter controller board show 24V?

NO

Is a voltage of 24V being supplied from the copier?

 

 

NO

Check the 24V-power supply of the copier.

 

 

 

 

YES

Replace the sorter controller board.

YES

Is stapler-unit swing switch (MS9) working normally?

 

 

 

 

 

 

 

NO

Replace the stapler-unit swing switch (MS9).

 

 

 

 

YES

 

 

Does the resistance between J9-1 and J9-2 on the harness side measure approx. 25Ω?

 

 

 

 

 

 

 

NO

Replace the stapler-unit swing motor (M5).

 

 

 

 

YES

 

 

Replace the sorter controller board.