CCC

No power being supplied

Are the signal cords J1 and J20 connected correctly?

NO

Correct the wiring.

 

YES

Does the circuit breaker (CB2) on the sorter controller board function normally?

 

 

YES

Press the circuit breaker.

NO

 

 

 

 

 

 

 

 

Is the fuse blown out?

YES

Replace the fuse.

 

NO

Using the 50V (DC) tester range, measure the voltage between J1-1 (+) and J1-2 (–) on the sorter controller board; does it show approx. 24V?

NO

Check the copier’s 24V-power supply.

 

YES

Using the 50V (DC) tester range, measure the voltage between J1-3 (+) and J1-4(–) on the sorter controller board; does it show approx. 24V?

NO

YES

Check the copier’s 24V-power supply.

Replace the sorter controller board; is the power supplied normally?

NO

YES

Complete.

Replace the copier’s DC controller board.

FC-22 TROUBLESHOOTING