Toshiba manual FC-22 Troubleshooting

Models: FC-22

1 238
Download 238 pages 20.74 Kb
Page 157
Image 157

C43 Thermistor abnormal during warming-up after abnormality judgment

1. Checking the thermistors, fuser lamps, SSR and LGC board

Check the thermistors, fuser lamps, SSR and LGC board, following the same procedure as in 1, 2 and 3 of C41 .

2. Clearing the status counter

Since [4] is shown on the status counter, rewrite it to [0], following the same procedure as in 4 of C41 .

C44 Heater abnormal during warming-up after abnormality judgment

1. Checking the thermistors, fuser lamps, SSR and LGC board

Check the thermistors, fuser lamps, SSR and LGC board, following the same procedure as in 1, 2 and 3 of C41 .

2. Clearing the status counter

Since [5] is shown on the status counter, rewrite it to [0], following the same procedure as in 4 of C41 .

C46

Heater abnormal (low temperature) after the copier has become ready

1. Checking the thermistors, fuser lamps, SSR and LGC board

Check the thermistors, fuser lamps, SSR and LGC board, following the same procedure as in 1, 2 and 3 of C41 .

2. Clearing the status counter

Since [7] is shown on the status counter, rewrite it to [0], following the same procedure as in 4 of C41 .

C47 Rear thermistor abnormal after the copier has become ready

1. Checking the thermistors, fuser lamps, SSR and LGC board

Check the thermistors, fuser lamps, SSR and LGC board, following the same procedure as in 1, 2 and 3 of C41 .

2. Clearing the status counter

Since [8] is shown on the status counter, rewrite it to [0], following the same procedure as in 4 of C41 .

January 2000 © TOSHIBA TEC

4 - 31

FC-22 TROUBLESHOOTING

Page 157
Image 157
Toshiba manual FC-22 Troubleshooting