E46

Bypass unit opened during copying

Is the bypass unit open?

YES

Close the bypass unit.

 

NO

Is the harness between the LGC board and the bypass unit open/close switch open-circuited? Is the bypass unit open/close switch connector or the connector J107 on the LGC board dis- connected?

YES

Reconnect the connector. Replace the harness.

 

NO

1.Replace the bypass unit open/close switch.

2.Replace the LGC board.

4.1.5Paper jam in ADU and reversing area

E50 Paper not reaching the ADU

E51 Paper not restarting from the ADU stack

E54 ADU paper transport jam

Is the ADU unit mounted securely on the copier?

NO

YES

Mount the ADU unit securely to the copier.

Is the connector J103 on the LGC board disconnected?

Is the harness between the LGC board and the ADU drawer connector open-circuited?

YES

NO

Reconnect the connector. Replace the harness.

1.Replace the LGC board.

2.Replace the ADU unit.