Toshiba FC-22 manual Group

Models: FC-22

1 238
Download 238 pages 20.74 Kb
Page 29
Image 29

 

 

 

 

 

Acceptable

 

 

Operation

Code

Description/Mode

Default

Contents

procedure

 

 

 

 

 

Value

 

 

group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

Automatic filling of developer

All (Y, M, C, K)

0~255

After filling the developer from the de-

5

 

 

 

 

 

 

veloper cartridge (approx. 2.5min.),

 

201

material and automatic ad-

Y

0~255

5

 

 

 

 

 

 

 

 

 

202

justment of the auto-toner cir-

M

0~255

auto-toner sensor output is adjusted

5

 

 

 

 

 

 

(approx. 2min.) to set in the range of

 

203

cuit

C

0~255

5

 

 

 

 

 

 

4.00-4.33V. (As the value increases,

 

204

 

 

K

0~255

5

 

 

 

 

 

 

the sensor output increases.)

 

221

 

 

Color (Y, M, C)

0~255

5

 

 

 

 

 

 

 

213

Auto toner output value

 

0

0~1023

Auto toner output value is displayed.

10

 

 

 

 

 

 

 

 

223

Developer bias DC (–)

Y

130

0~255

As the value increases, the transformer

1

224

output adjustment

M

130

0~255

output increases. The adjustment value

1

225

 

 

C

130

0~255

becomes effective only when the setting

1

226

 

 

K

125

0~255

mode (08-400, 401, 409) is 0 (disabled).

1

241

Main charger grid bias

Y

120

0~255

As the value increases, the transformer

1

242

output adjustment

M

120

0~255

output increases. The adjustment value

1

243

 

 

C

120

0~255

becomes effective only when the setting

1

244

 

 

K

116

0~255

mode (08-400, 401, 409) is 0 (disabled).

1

245

Automatic adjustment of the

All

0~255

Auto-toner sensor output is

5

 

auto-toner circuit

 

 

 

adjusted (approx. 2 min.) to set

 

 

(Without automatic filling of

(C, M, Y, K)

 

 

in the range of 4.00~4.33V. (As

 

 

developer material)

 

 

 

the value increases, the sensor

 

 

 

 

 

 

 

output increases.)

 

246

 

 

Y

0~255

 

 

 

 

 

 

 

 

 

 

247

 

 

M

0~255

 

 

 

 

 

 

 

 

 

 

 

 

248

 

 

C

0~255

 

 

 

249

 

 

K

0~255

 

 

 

 

 

 

 

 

 

 

 

 

250

 

 

Color

0~255

 

 

 

 

 

 

(Y, M, C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

252-0

Main charger bias

 

Y

250

0~999

Actual output voltage of main

4

252-1

output voltage 1 (lower)

M

250

0~999

charger grid bias. After replacing

4

252-2

 

 

C

250

0~999

the main high-voltage transformer,

4

252-3

 

 

K

250

0~999

input the value according to the

4

253-0

Main charger bias

Y

900

0~999

supplementary data sheet.

4

253-1

output voltage 2 (upper)

M

900

0~999

 

 

4

253-2

 

 

C

900

0~999

 

 

4

 

 

 

 

 

 

 

 

 

253-3

 

 

K

900

0~999

 

 

4

 

 

 

 

 

 

 

257-0

Developer bias DC (–)

Y

100

0~999

Actual output voltage of developer

4

 

 

 

 

 

 

 

 

257-1

output voltage 1 (lower)

M

100

0~999

bias. After replacing the main high-

4

257-2

 

 

C

100

0~999

voltage transformer, input the value

4

 

 

 

 

 

 

 

 

 

257-3

 

 

K

100

0~999

according to the supplementary

4

 

 

 

 

 

 

 

 

258-0

Developer bias DC (–)

Y

700

0~999

data sheet.

4

 

 

 

 

 

 

 

 

258-1

output voltage 2 (upper)

M

700

0~999

 

 

4

 

 

 

 

 

 

 

 

 

258-2

 

 

C

700

0~999

 

 

4

 

 

 

 

 

 

 

 

 

258-3

 

 

K

700

0~999

 

 

4

 

 

 

 

 

 

 

 

 

January 2000 © TOSHIBA TEC

1 - 21

FC-22 ADJUSTMENT

Page 29
Image 29
Toshiba FC-22 manual Group