4.1.12Copy process related service call

C31

Used toner transport motor rotation abnormal

Is the harness between the LGC board and the used toner transport motor open-circuited? Is the connector J122 or J102 on the LGC board, the relay connector or the used toner trans- port motor connector disconnected?

YES

Replace the harness. Reconnect the connectors.

 

NO

Is used toner jammed? Is any abnormal mechanical load found?

YES

NO

1.Remove the jammed used toner.

2.Check for any foreign matter in the drive system.

3.Check the bearing of the used toner transport auger for any abnormality.

4.Check if the toner bag is covered with used toner.

1.Replace the used toner transport motor.

2.Replace the LGC board.

*Since the used toner jamming can cause a serious damage to EPU, be sure to check that the EPU functions normally.

January 2000 © TOSHIBA TEC

4 - 25

FC-22 TROUBLESHOOTING

Page 151