Toshiba FC-22 manual C29 Exposure lamp disconnection detected

Models: FC-22

1 238
Download 238 pages 20.74 Kb
Page 150
Image 150

C29

Exposure lamp disconnection detected

Does the exposure lamp light?

NO

YES

1.Check the CCD and SCM boards for any disconnected connector.

2.Check the shading correction plate of the original-width indicator unit if it is dusty.

3.Check the CCD board for any open- or short-circuited conductor pattern.

4.Check the SCM board for any open- or short-circuited conductor pattern.

5.Replace the lens unit.

6.Replace the SCM board.

1.Check if the lamp connector is disconnected.

2.Check if the thermostat is blown out.

3.Check if the lamp has continuity.

4.Check the SCM board if any pin of connectors J7-B1, -B2, -B4, -B5 and -B6 is disconnected or any harness is open- or short-circuited.

5.Check the SCM board for any open- or short-circuited conductor pattern.

6.Replace the SCM board.

7.Replace the lamp regulator.

FC-22 TROUBLESHOOTING

4 - 24

January 2000 © TOSHIBA TEC