January 2000 © TOSHIBA TEC 1 - 15 FC-22 ADJUSTMENT
1. 2. 2 Output check (Test mode 03)Output signal status can be checked by inputting the following code according to this test mode 03.
150 All output OFF 1
101
Drum motor and transfer belt motor rotation with normal running speed ON
151 Code No. 101 function OFF 1
102
Drum motor and transfer belt motor rotation with OHP copying speed (low) ON
152 Code No. 102 function OFF 1
103 Paper feed motor ON 153 Code No. 103 function OFF 1
104 Fuser motor ON 154 Code No. 104 function OFF 1
105 Color developer motor ON 155 Code No. 105 function OFF 1
106 Black developer motor ON 156 Code No. 106 function OFF 1
107 Registration clutch ON 157 Code No. 107 function OFF 1
108 Used-toner transport motor ON 158 Code No. 108 function OFF 1
109 ADU motor ON 159 Code No. 109 function OFF 1
110 Toner motor (Y) ON 160 Code No. 110 function OFF 1
111 Toner motor (M) ON 161 Code No. 111 function OFF 1
112 Toner motor (C) ON 162 Code No. 112 function OFF 1
113 Toner motor (K) ON 163 Code No. 113 function OFF 1
114 Image quality sensor shutter solenoid ON 164 Code No. 114 function OFF 1
130 Polygonal motor standby speed ON 180 Code No. 130 function OFF 1
131 Polygonal motor normal speed ON 181 Code No. 131 function OFF 1
132 Image quality sensor LED ON 182 Code No. 132 function OFF 1
133 Color registration sensor LED (front) ON 183 Code No. 133 function OFF 1
134 Color registration sensor LED (rear) ON 184 Code No. 134 function OFF 1
135
Image quality sensor mode switching ON (Black mode)
185
Code No. 135 function OFF (Color mode)
1
201 1st cassette feed clutch ON/OFF 3
202 2nd cassette feed clutch ON/OFF 3
203 3rd cassette feed clutch ON/OFF 3
204 4th cassette feed clutch ON/OFF 3
205 Feed path clutch ON/OFF 2
206 Bypass feed clutch ON/OFF 3
207 1st cassette tray-up motor ON (tray goes up) 2
208 2nd cassette tray-up motor ON (tray goes up) 2
209 3rd cassette tray-up motor ON (tray goes up) 2
210 4th cassette tray-up motor ON (tray goes up) 2
211 Paper-exit gate solenoid ON/OFF 3
212 Total counter count up 2
213 Ozone exhaust fan motor ON/OFF 3
214 Fuser exhaust fan motor speed Low/High 3
Code Function Code Function Procedure