January 2000 © TOSHIBA TEC 1 - 47 FC-22 ADJUSTMENT
(7) When the copier starts operating, a message “WAIT” is shown and the developer material filling
starts (approx. 2 minutes and 30 seconds).
WAIT
(8) Approx. 2 minutes after the developer material filling is finished, the following display appears:
훾촞 Y:6.30V M:6.38V C:6.38V K:6.38V
훿촞 61%
훽촞 Y:4.00V M:4.00V C:4.00V K:4.00V
Upper line 훾 : Current sensor voltages (V)
Middle line 훿 : Humidity (%)
Lower line 훽 : T arget values (V) for adjustment ref erence voltages
Note:
•The current sensor voltages (V) shown in 훾 automatically changes, gradually approaching the target values
for adjustment reference voltages shown in 훽.
•Values are displayed only for the developer materials being filled.
(9) In 30 to 60 seconds, the current sensor voltages (V) in 훾 are converged to those in 훽. The humidity
shown in 훿 disappears, and the sensor output control values (bit values) are shown instead.
훾촞 Y:4.00V M:4.00V C:4.00V K:4.00V
훿촞 Y: 135 M: 135 C: 135 K: 135
훽촞 Y:4.00V M:4.00V C:4.00V K:4.00V
Note: Be careful that the values in 훽, 훾 and 훿 vary with humidity.
훽 : Target value (V) for adjustment reference voltage
Humidity (%) Y M C K
~59.9 4.00 4.00 4.00 4.00
60.0~74.9 4.14 4.14 4.14 4.12
75.0~ 4.35 4.35 4.35 4.31