7)Once the Cool Down Cycle is completed, the Phase 7 non-coin microprocessor controller (computer) will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound (for the amount set in Audio Alert On Time). The light emitting diode (L.E.D.) display will read “CYCLE DONE”. The dryer will wait an initial 15 minute delay before going into a 15-seconds ON, 5 minutes OFF cycle. These times are fixed and are not programmable. During the ON Time, the blower (fan) and the basket (tumbler) will start to rotate without heat for 15-seconds; during this time, the display will read “WRINKLE GUARD”. After the 15-seconds are completed, the display will read “CYCLE DONE” and the dryer will go into a 5 minute OFF cycle. The Phase 7 non-coin microprocessor controller (computer) will repeat this process of 15-seconds “ON” and 5 minutes “OFF” until either

the doors are opened, the “STOP/CLEAR” key is pressed, or 99 minutes have elapsed, whichever comes first. Once the 99 minutes have elapsed, the L.E.D. display will then read “CYCLE DONE” and the Phase 7 non-coin microprocessor controller (computer) will lock out the dryer functions until the doors are opened. The L.E.D. display will then return to “READY”.

2.Manually Loaded Cycles

a. Automatic Drying Cycle (Patent No. 4,827,627)

1)L.E.D. display reads “READY” (no cycle in progress).

2) Press AUTO

key.

3)L.E.D. display will now read ENTER DRY TEMP 160 TO 200. (Defaults to 160° F [71° C]). Enter the temperature desired (from 160° F to 200° F [71° C to 93° C] in one-degree increments).

I.E., for 180° F (82° C), press key “1”, key “8”, key “0”, and then press the “START/ENTER” key to accept the value.

4)L.E.D. display will now read ENTER DRY LEVEL: finishing, dry, and extra dry. Enter the amount of extraction (dryness level) desired. Finishing has the most moisture content, dry has less moisture content, and extra dry has little or no moisture content.

5)L.E.D. display will now read “REVERSE MODE” (defaults to ON). The ON/OFF selection can

be toggled with the “UP ARROW” and “DOWN ARROW” . Once selected, press the “START/ENTER” key to accept selection.

NOTE: In addition to entering a value by pressing the number keys, the “UPARROW” and “DOWN ARROW” can be used to scroll to the number desired, or to toggle between selections.

6)At the start of a cycle, the L.E.D. display will initially display the cycle parameters of the selected cycle: AUTO DRYING CYCLE, TEMP 180, DRYNESS LEVEL EX DRY. Then the display will read: AUTO CYCLE, ELAPSED TIME 00:00 MINUTES. The L.E.D. display will continue to show AUTO CYCLE, ELAPSED TIME XX:XX MINUTES, until the load is dried to the appropriate dryness level or the auto cycle time out time has expired.

NOTE: Press and hold the “UPARROW” to view the basket (tumbler) temperature at any time.

NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR” key; at this time, the dryer will go into a cycle pause. If the “STOP/CLEAR” key is pressed again at this point, the cycle that was in progress will be cancelled and returned to the “READY” state.

16

Image 18
Contents NON-COIN Retain This Manual In a Safe Place For Future Reference Table of Contents Section Phase 7 NON-COIN Auto Cycle Patent no ,827,627 Section Features Keyboard Touch Pad Symbols = STOP/CLEAR key Program Selections Preprogrammed CyclesPage Manually Loaded Cycles Automatic Drying Cycle Patent no ,827,627 OperationsTimed Manual Drying Cycle Operation Cycle in Progress Temperature Display Temperature Conversion StatusLight Emitting Diode L.E.D. DOT Matrix Display Wrinkle Guard Program Audio Alert on Times 0 toPreprogrammed Cycle Preview Diagnostics Reversing OptionProgram Locations Page Preprogrammed Locations for Custom Drying Operating Instructions Operating SequencePage Page MAN Operating Notes System Reset Fire Suppression System F.S.S. Theory of OperationFire Suppression System F.S.S. Valve Check Page D. Display Messages E.D. Display Operating StatusProgramming Instructions Introduction to ProgrammingPage Programming Flowcharts START/ENTER STOP/CLEARPhase Menu Programming Procedure Page Auto Reverse Mode On OFF English Selecting Languages0SELECT Language EspanolSelect System Parameters Dryer SetupSelecting a Dryer Model Select ModelSteam NON-REVERSING GAS ReversingGAS REVERSING, Electric REVERSING, Steam REVERSING, GAS NON Electric ReversingSelecting the System Temperature Enter Lint Cleaning Frequency 1 to 10 Hours DEG FDEG C Setting the Lint Cleaning Frequency Enter Audio Alert on Times 0 to Adjusting the Audio Alert On times System Temp Rotation Sensor Rotation Sensor Press Enter to jump directly to the location OFF Board Address 00 to ZZDryer Address To ZZ Auto Cycle Time OUT to 99 Minutes Auto Cycle Time Out System Temp Enter Lint Cleaning Frequency 1 to 10 Hours Enter Audio Alert on Times 0 to Rotation SensorAuto Cycle Time OUT To 99 Minutes Adjusting Reversing Spin Time and Stop Time Reversing Setup Enter Spin Time 30 to 120 SecondsEnter Stop Time 5 to 10 Seconds Press the up arrow key to increment Setup Wrinkle Guard Audio AlertWrinkle Guard Setup Wrinkle Guard Audio AlertSteam Injection Setup Wrinkle Guard Setup Steam Injection Setup Enter 1ST on Time Cycle511 to 000 First time adjustment is Minutes mm Enter 1ST OFF TimeEnter 2ND on Time Enter 3RD on Time Program 0-40 CyclesProgramming a F Cycles or 0 40 Cycles Program System Cycles ParametersSelect Cycle Type Reverse ModeSelect a F KEY AutoOFF Not Available Not AvailableEnter DRY Temp TimeEnter Dryness Level DRYEnter Stop Time To 10 Seconds Enter Cycle Adjustment DRY or Extra Extra DRYEnter DRY Time 0 to 99 Minutes Controlled Cool Down Enter Cool Down Time 0 to 99 MinutesEnter Cool Down Temp 70 to 100 ºF Enter Cool DownSteam Injection Cycle Enter 1ST on Time 511 to From Previous Enter 2ND on Time Enter 3RD on Time Restoring Factory Default Settings Enter Password Confirm Defaults Defaults SET Default Settings YESCycle A-F Parameters Programs Preset by the Factory Cycle 0-40 Parameters Programs Preset by the FactoryPreprogrammed Cycles System Parameters Program Locations Fixed ParametersGas Diagnostic L.E.D. Display Fault Messages StandardsPage Page Page S.S. Diagnostic Conditions INPUT/OUTPUT I/O Board L.E.D. Indicators Brhl RED L.E.DKeyboard Touch PAD Layout Customer Custom Parameter Settings Auto Programmed Cycle Page ADC Part No 08/19/08