Hand Held Products 800, 600 manual Character Font & Tolerances

Page 29

The Yes setting for this parameter is the default. Some of the extra characters are represented by special character “strings” as shown in the following Character Translation Table. When you select the No setting, this information does not appear on the display or the printout.

Character Translation Table

(Code 128, Code 16K, and Code 49)

Character

On

On

Character

On

On

LCD

Printout

LCD

Printout

 

 

 

 

 

 

 

 

00(NUL)

0

<NL>

15(NAK)

15

<NK>

01(SOH)

1

<SH>

16(SYN)

16

<SY>

02(STX)

2

<SX>

17(ETB)

17

<EB>

03(ETX)

3

<EX>

18(CAN)

18

<CN>

04(EOT)

4

<ET>

19(EM)

19

<EM>

05(ENQ)

5

<EQ>

1A(SUB)

1A

<SB>

06(ACK)

6

<AK>

1B(ESC)

1B

<ES>

07(BEL)

7

<8L>

1C(FS)

1C

<FS>

08(BS)

8

<BS>

1D(GS)

1D

<GS>

09(HT)

9

<HT>

1E(RS)

1E

<RS>

0A(LF)

A

<LF>

1F(US)

1F

<US>

0B(VT)

B

<VT>

7F(DEL)

*

<DL>

0C(FF)

C

<FF>

FCN1

F1

<F1>

0D(CR)

D

<CR>

FCN2

F2

<F2>

0E(SO)

E

<SO>

FCN3

F3

<F3>

0F(SI)

F

<SI>

FCN4

F4

<F4>

10(DLE)

10

<DE>

Mode A

A

<A:>

11(DCI)

11

<D1>

Mode B

B

<B:>

12(DC2)

12

<D2>

Mode C

C

<C:>

13(DC3)

13

<D3>

Shift

Sh

<Sh>

14(DC4)

14

<D4>

Pad**

Pd

Pd

 

 

 

 

 

 

*No “special” character is displayed for <DEL>.

**For Code 16K only.

Character Font & Tolerances

Codabar supports two options for Character font and tolerances.

Trad’l (Traditional Codabar) uses traditional print tolerances based on Monarch’s original print tolerances. This is the default setting.

USS Codabar uses the ISO/IEC 1983 MH10.8M standards.

Refer to Codabar and ISO/IEC publications for specific information on print tolerances.

Quick Check® 600/800 Series User’s Guide

3 - 5

Image 29
Contents User’s Guide Waste Electrical and Electronic Equipment Information DisclaimerFor European Community Users Table of Contents Reviewing Scan Data Saving and Printing Chapter Customer Support About This Guide Getting StartedTerm in manual Term in software SymbolDescription Power or Select or ↑, ↓, ←, →Unpacking the Quick Check 600/800 Verifier Quick Check 600/800 Verifier Noting the Verifier’s FeaturesEAN/UPC Display Special FeaturesLEDs ButtonsPorts Specification SpecificationsInstalling the Batteries To charge the batteries To Install the BatteriesCharging the Batteries To turn on the unit Turning the Unit On and OffNo Printer Attached, then refer to .a Quick Check 600/800 Series User’s Guide To calibrate the Quick Check 600/800 Verifier Calibrating the Quick Check 600/800 VerifierTo turn off the unit Properly Scanning With the Unit To scan properly using a pen wandTo scan properly using a mouse wand Item/DescriptionOrder code Cleaning the WandAccessories and Options Documentation Quick Check 600/800 Series User’s Guide Quick Start Guide Print your scan results Review the option settingsSymbologies Changing the SettingsChanging the Specifications Symbologies Symbology Parameters defaults are in bold Symbology SpecificationsExpand U.P.C./EO Magnification FactorCheck Options Modes ShownCharacter Translation Table Code 128, Code 16K, and Code Character Font & TolerancesWide-to-Narrow Ratio To modify the symbology optionsFixed Message Length → or SelectIndustry Applications To select an application Changing the Test CriteriaScan Grade Number of Scans DecodabilityISO/IEC grades To change the test criteria To return to the previous menu, press PowerChanging the Scanning Options Extended Accuracy Beeper PitchDecode Direction To change the scanning optionsParameter Result Lines Changing the Output OptionsDisplay Options AutoPrint/Store Print OptionsTo change the display options Scan ProfileTo change the output options Locking the Settings Resetting the Default SettingsTo reset a unit To change the printout optionsAbout Command Codes Using a Command CodeGeneric Code Selections C./EAN/JAN Enable On or OffCustomized Command Codes Choosing a Command CodeTo request a Command Code from Hand Held Products To use a customized Command CodeTo create a customized Command Code Quick Check 600/800 Series User’s Guide Scan Grades Reviewing Scan DataReviewing Scan Results ISO/IEC Symbol Grade Determining the ISO/IEC Symbol Grade Quick Check 600/800 Series User’s Guide Reviewing a Scan Example To obtain the scan grade and ISO/IEC Symbol gradeQuick Check 600/800 Series User’s Guide To review data from the last scan LED DisplayBar growth LCD bar growth LED lit Tolerance used Indication Audio SoundsErrors in Dimensional Parameters Reviewing the Dimensional ParametersParameter Trad’l Parameter ResultCalculating To review the dimensional parametersReviewing the Reflectance Parameters PCS Errors in Reflectance ParametersTo review the reflectance parameters Symbol Contrast, Minimum and Maximum ReflectanceReviewing the Format Parameters Errors in Format ParametersReviewing Messages To review the format proceduresSstr Code Type Test Criteria Name Using Sstr Codes to Review DataSstr Codes To quickly review data using Sstr Codes Using the Quick Check Verifier as a ReflectometerTo return the customized display to the default display To customize the result displayTo use the Quick Check Verifier as a static reflectometer Saving Data Saving and PrintingChecking the Print Buffer During Operation To save scan dataTo check the print buffer during operation Printing DataTo clear delete the records stored in the memory, press → To print current dataTo stop printing Deleting Stored DataTo print stored data To delete stored data Interfacing With a ComputerReviewing the Printouts QCP and Qchsp Printouts Printing Guidelines Using the QCP or QchspSwitch Position Function To turn on and off the QCP or Qchsp To set up the QCP or QchspTo install or replace the QCP or Qchsp paper roll To remove the ribbon from the QCP or Qchsp To perform a QCP or Qchsp self-test Troubleshooting the QCP or Qchsp Quick Check 600/800 Series User’s Guide General Bar Code Information Background InformationSymbology Industries Organization Symbology SpecificationsGS1 formerly UCC and EAN Symbology Characteristics Quick Check 600/800 Series User’s Guide Element Symbology Character Set WidthsHow a Bar Code Verifier Works Additional Information Quick Check 600/800 Series User’s Guide Understanding the DataMatch Feature Using DataMatchDownloading DataMatch Structuring and Loading the Database SYM Identifier CodeTo load the database into the verifier DecodeQuick Check 600/800 Series User’s Guide To select DataMatch Selecting the DataMatch FeatureReviewing DataMatch Results Quick Check 600/800 Series User’s Guide General Operation Using a Quick Check 800 VerifierScanProfile Output Percent Decoded/Scanned ModeReflectance-Based Information Print Results Calculate Decoded/Scanned Change Settings Change Settings Test Criteria #Scans/Symbol nnn Type Display Message Printout Message Error, Application, and Type MessagesDatabase ECV /VCVS Bookland Quick Check 600/800 Series User’s Guide Ccbba Hibcc EAN ITF SCS /ITF EAN SCS Quick Check 600/800 Series User’s Guide Flow Charts Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Sstr Codes Quick Check 600/800 Series User’s Guide Special Codes Quick Check 600/800 Series User’s Guide Unrecognized Symbols Unrecognized SymbolsQuick Check 600/800 Series User’s Guide To restore the display TroubleshootingCustomer Support To check the software versionLatin America Limited Warranty Quick Check 600/800 Series User’s Guide Page Hand Held Products, Inc