Reflectance-Based Information
When connected to a QC3800V, the Main display indicates the Series 800 verifier model, and the bottom line displays:
Linear Imager
Once a successful scan is performed, the Main display shows, for example:
C39:ABCD012345678
Dim
Decod’ty 75% <A>
WN Ratio 2.3 OK!
Note that the second line, where the reflectance information would normally be displayed, shows
ScanProfile Output
No ScanProfile Output is available in either the Printer Output modes or the "PROF to PC" mode (as used by QCViewerII software).
Percent Decoded/Scanned Mode
No Reflectance Calibration is necessary when the QC3800V is connected. When a Mouse Wand or Pen Wand is reconnected, however, the reflectance calibration is necessary.
When using the QC3800V, a special Percent Decoded/Scanned Mode replaces the Reflectometer Mode found on a Series 600 verifier. When the QC3800V is connected, the second level (Print Results) menu changes from:
*Print Results
*Calculate "X"
*Reflectometer
*Change Settings
8 - 2 | Quick Check® 600/800 Series User’s Guide |